Does CPS aid energy resolution of Z - PowerPoint PPT Presentation

1 / 10
About This Presentation
Title:

Does CPS aid energy resolution of Z

Description:

See http://d0server1.fnal.gov/Users/ dalton/CPS_d0note_v1.doc. CPS purpose. Recover EM energy resolution lost by solenoid and other tracking materials ... – PowerPoint PPT presentation

Number of Views:12
Avg rating:3.0/5.0
Slides: 11
Provided by: andrew624
Category:
Tags: cps | aid | dalton | energy | resolution

less

Transcript and Presenter's Notes

Title: Does CPS aid energy resolution of Z


1
Does CPS aid energy resolution of ZsPart 3
  • Drew Alton
  • University of Michigan
  • See http//d0server1.fnal.gov/Users/
  • dalton/CPS_d0note_v1.doc

2
CPS purpose
  • Recover EM energy resolution lost by solenoid and
    other tracking materials
  • Improve EM identification
  • Better spatial match then Cal. for track
    matching. And other separation of electrons from
    fakes.
  • Separation of p0 and g.
  • Soft electron tag for b jet id.
  • CPS is ready for all of these.
  • What about EM energy resolution

3
Plan
  • Take MC Zs and extract layer weights for 5
    layers(EM1-4FH) and 6 layers(CPS)
  • Match electrons (reconstructed to MC) 0.02 in h f
  • c2 S(a0Ecps a1Eem1 a2Eem2 a3Eem3
    a4Eem4 a5Efh Emc)
  • Minumize wrt as gives 6 equations and 6 unknowns.
  • Solve the linear algebra and get as
  • Apply and see how much better the resolution is.
  • Now look at saturation effects.
  • Smearing effects.
  • Comparison to D0 note 3535

4
D0 Note 3535
  • This note looked at including CPS Energy in layer
    weights.
  • Used single 50 GeV electrons at fixed eta and
    phi.
  • Phi hit center of module
  • No clustering for Cal or CPS, all geant energy
    used.
  • Determined CPS needed 10 calibration.
  • My Z-gtee MC studies didnt agree
  • Generated single e MC at 50 GeV energy, at 4
    fixed eta just like they did. (obviously not
    just like)

5
MC vs MC
  • Energy Resolution vs eta
  • Note differences
  • Fixed phi/eta vs whole dist
  • Clustered Cal and CPS
  • Saturated CPS (60 MeV)
  • Anything else?

6
More MC vs MC
  • Energy Resolution vs smearing

7
Saturation
  • MC saturation at 60 MeV.
  • Less then 10 of electrons have saturated strip
  • Almost 30 have floorE(0)0.
  • Apply other saturations
  • CPS cluster
  • 3 layers
  • Each layer 5 or less strips
  • Only have strip energy for center 3

Cal only Raw from MC
Cal only New MC weights
Electron energy resolution in Z-gtee
Saturation of CPS in GeV
8
Saturation and smearing
Cal only Raw from MC
  • Smear for 2 saturations.
  • Smear each available channel by gaussian
  • Gaussian centered on MC value, with sigma a
    fraction of that value.

Saturation of 0.02 GeV
Cal only New MC weights
Saturation of 0.06 GeV
9
Conclusions/Plans
  • Saturation is worse than mis-calibration.
  • Gain set to saturate at 60 MeV is reasonably good
    for electrons from Z and W.
  • No one cares about CPS for higher pt electrons
    right?
  • Refocus our efforts to
  • Set the gain in this fashion
  • Extrapolate for the 10 which saturate
  • Calibration will be left with the 30
    uncertainty.
  • Make MC and Data agree as well as we can.

10
What went wrong
  • Turns out the pipeline of the svx saturates at
    about 20 above how we are operating the detector
    now.
  • The only fix would involve removing all CPS
    boards and changing capacitors.
  • Other options
  • Counting strips
  • Achieves 2/3 the improvements of perfectly
    calibrated cps
  • predicting the energy lost due to saturation
  • Simple predictions based on the MC give an
    effective smearing of 10. Should be smaller
    than but about the same as smearing from
    calibration.
Write a Comment
User Comments (0)
About PowerShow.com