Title: Electrical Signaling: Serial Ports


1
Electrical Signaling Serial Ports
  • EIA/TIA-232 Serial Ports (Chapter 4)
  • One is a low voltage (-3 to -15 volts)
  • Zero is a high voltage (3 to 15 volts)
  • 300 bps to 115.2 kbps
  • Length of clock cycle is 1/bit rate

0
1
0
0
1
2
Electrical Signaling Loss of Synch
  • Problem of Long String of Ones or Zeros
  • No transition to resynchronize receivers clock
  • Receiver may interpret bit N as N-1 or N1
  • At 10 Mbps or 100 Mbps, bit periods are so brief
    that synchronization must be very exact

Sender
1
2
3
4
5
6
Receiver
1
2
3
4
5
3
Electrical Signaling 10Base-T
  • Manchester Encoding
  • Used in 10Base-T only
  • Two voltage levels
  • High TD (Pin 1) is 2.2 to 2.8 volts higher than
    TD- (Pin 2)
  • Low TD is 2.2 to 2.8 volts lower than TD-

High
Low
1
1
0
1
4
Electrical Signaling 10Base-T
  • Manchester Encoding
  • Used in 10Base-T
  • Transition in middle of each bit period
  • One ends high zero ends low
  • Resynchronizes receivers clock every bit

Transition in mid-bit
1 ends high
1
1
0
1
5
Electrical Signaling 10Base-T
  • Manchester Encoding is Inefficient
  • Baud rate is number of possible transitions per
    second
  • Baud rate is the limiting factor technically
  • 20 Mbaud to deliver only 10 Mbps

8 possible transitions
4 bits
1
1
0
1