Title: GenPrime Investor Presentation


1
Innovations for a Secure and Healthy World

2
Core Technologies
  • Core technologies in multiple industries

Cheese Dairy
Water Beverages
1999
2006
GenPrime Technologies
Rapid
Microbe Detection
(Broad Patent
Protection)
Founded 1997
Fermentation
Blood Products
2000
2005
Homeland Security
2002
3
Platelet Contamination
               
Bacterial Contamination of Platelets is a Major
Concern to the Medical Community
AABB Standard 5.1.5.1 requires bacterial testing
on every platelet unit (100 QC)
4
Industry Requirements
Blood Banks Hospitals Need
Robust Bacterial Assay
  • Rapid
  • Sensitive
  • Cost-effective
  • User-friendly
  • Computer interface capability

Of the current methods, the rapid
assays are not sensitive and the sensitive assays
are not rapid.
5

Current Methods
Bacterial Detection in Platelets
  • Method Sensitivity
  • Staining/microscopy 106 cfu/ml
  • Dipsticks pH glucose 107 cfu/ml
  • Swirling 107 cfu/ml
  • O2 consumption Pall eBDS lt102 cfu/ml
  • CO2 generation BacT/ALERT lt102 cfu/ml

Rapid (No Culture required)
Slow (Culture required)
Additional methods are under development
6
GenPrime's Approach
GenPrime Expanded its Antibody Technology
to Develop a Rapid Bacterial Test - BacSTAT
  • Broad-spectrum antibody-based lateral flow
    device for detection of bacteria in apheresis
    or whole blood derived platelets
  • Unique lateral-flow scanning system
  • Pass/Fail software system

7
GenPrimes Technology
               
Broad-Spectrum Antibody Detection of Bacteria
Unique Bar Code
Control Line
(pos)
A single lateral-flow antibody
strip detects all 14
contaminating organisms.
(neg)
8
Platelet Bacteria
Target Organisms Target
Sensitivity
S. epidermidis   S. aureus   B. cereus   B.
subtilis  Ps. aeruginosa   Streptococcus
viridans/mitis   Streptococcus pyogenes  E. coli
  Klebsiella oxytoca  Serratia marcescens
  Enterobacter cloacae   Corynebacterium
xerosis  Propionibacterium acnes  Clostridium
perfringens  
103 cfu/ml
9
Bacterial Detection
               
Preliminary Data with BacSTAT
Current sensitivity for detection of E. coli in
platelets is 104 cfu/ml.
107 106 105 104 103
10
Assay Method
The Assay is Simple and Rapid
Total Test Time is Less Than 20
Minutes
1 ml Platelet Sample
Run Lateral-Flow Strip
Scan and Log Data
Sample Prep
(lt 1 min)
(3 min)
(15 min)
(lt I min)
Multiple tests can be carried out simultaneously.
11
BacStat
BacSTAT Detects Bacteria with Objective Results
Rapid Lateral-Flow Scanner
The BacSTAT employs pass/fail threshold software
to determine if platelets
are contaminated.
Antibody Strips
12
Validation for FDA
Validation Plan for BacSTAT as QC Indication
  • Sensitivity
  • Spiking studies in platelets
  • Test all 14 bacteria (aerobic and anaerobic)
  • Evaluate 10 samples for each concentration
    (10/10 detection limit)
  • Compare to Predicate Device
  • Spike platelets at 1 cfu/ml and collect samples
    at 24 hour intervals
  • Test each sample with BacSTAT, plate count and
    either BacT/ALERT or eBDS


  • Potential
    issues Low spiking level and some bacteria may
    not grow in platelets

13
Conclusion
BacSTAT is a robust bacterial detection test for
the QC of whole blood and apheresis
platelets prior to transfusion.
  • Simple - Dipstick format
  • Rapid - Total time less than 20 minutes
  • Sensitive - 103 cfu/ml
  • Automated Data Tracking

14
Jim Fleming Chief Technology Officer jfleming_at_genp