Title: Emmanuel MOULIN
1Project of a new generation detector for direct
detection of non-baryonic dark matter MACHe3,
MAtrix of Cells of superfluid Helium 3
- LPSC-CRTBT-LTL Collaboration
- LPSC (Grenoble) E. Moulin, F. Naraghi, D.
Santos - CRTBT (Grenoble) Yu. M. Bunkov, H. Godfrin,
C.Winkelman - LTL (Helsinki) M. Krusius
- Emmanuel MOULIN
- LPSC (ex-ISN) - Grenoble
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 1
2 Main topics
- MACHe3 project
-
- Results from first experiment
- Neutralino detection phenomenology
- Next steps
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 2
3 3He for non-baryonic DM search
3He in B phase at T 100 ?K
- spin 1/2 nucleus ? axial interaction with
neutralino - high purity ? no radioactive contamination
- neutron capture signature
- very low sensitivity to ? rays
- no intrinsic X rays
- detection threshold 1 keV
- high signal/noise ratio
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 3
4 MACHe3 project (1)
1000 bolometric cell matrix
a Lancaster type bolometric cell
- VWR (Vibrating Wire
- Resonance) damping
- thermal diffusion through
- the hole
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 4
5 MACHe3 project (2)
Rejection
- neutralino in 1-6 keV range
- ? high signal/noise ratio
- correlation between cells
Background events
- gammas from natural radio-
- activity (40K, Rn,)
- ? lead shielding 15 cm
- neutrons
- ? paraffine shielding 30 cm
- ? capture process signature
- muons
- ? many cells fired
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 5
6 Total rejection simulation (Geant4)
for 1000 cells of 100 ?m Cu thick
- neutron capture process
- ? good neutron rejection
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 6
7 Experimental results on prototype cell
cryostat
lead shielding
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 7
8Raw data at 100 ?K
50 keV muon deposit
Raw spectrum
Sensitivity
structures at 1.5 keV
peaks at 11.2 keV
1 keV
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 8
9Data analysis
data and noise adaptative filter
peaks in the 1-10 keV range with white noise
Gain 10
1 keV peak
? 1 keV peak is detected
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 9
10Neutron detection
n 3He p 3H 764 keV
- (Am/Be source)
- peak at 650 keV
- energy resolution
- of 3
- shift ( 14) UV photon emission, vortex
creation ?
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 10
11Muon detection (in prototype cell)
Experimental data ? peak at 52 keV
- Geant4 simulation
- peak at 67 keV
- shift (22) ? UV photon emission
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 11
12? MACHe3 3He-? cross-section
large scan of SUSY para- meter space
0.01 per day ? ultimate background
F. Mayet et al. Phys. Lett. B 538 (2002) 257
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 12
13 Complementarity with scalar direct detection
- axial and scalar signals
- not correlated
- MACHe3
- rate gt 0.01 day-1
F. Mayet et al. Phys. Lett. B 538 (2002) 257
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 13
14Next steps (1)
-
- ? test correlation
- between cells with
- a new acquisition system
- ? lines at 7, 14 , 115 et 129 keV
3 small cells
vibrating wires
- Low energy calibration with an
- electron conversion source (57Co)
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 14
15Next steps (2)
? detection of UV photons (with SQUID) in
progress opportunity for
scintillation/bolometer technique? ? in
different SUSY models (mSUGRA, AMSB, GMSB)
performance and complementarity with existing
detectors
- Neutralino detection phenomenology
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 15
16 8 keV copper X rays simulation(Geant4)
- X rays deposited energy in a 3He cell is
- either higher than 6 keV
- or lower than 1 keV
99.997 8 keV X rays depose less than 1 keV or
more than 6 keV
Event range
- Cu radioactivity 3 mBq/kg
- background for 10 kg
- matrix 5.10-2 jour-1
- (for 100 ?m thick cell)
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 16
17Matrix parameters
Ni incident particle number N particle number
giving a signal in matrix N1 unicellular event
number N6 unicellular event number giving less
than 6 keV M1,M6 defined as N1,N6 but for events
out of veto
- Cgeo N1/N
- Rener N1/ N6
- Cveto N1/M1
- Rint N/M6
- Rtot Ni/M6
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 17
18Gamma rejection
for 1000 cells of 5 cm large and 100 ?m Cu thick
_______________________________ E.MOULIN 4th
Marseille International Cosmology Conference
24/06 15
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 18
19Neutron rejection
for 1000 cells of 5 cm large and 100 ?m Cu thick
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 19
20Background rejection
- In a 10 kg matrix of 1000 cells in the LSM
- (underground laboratory)
- Monte carlo simulation
- neutron background (30 cm paraffine) 0.1 day-1
- muon background 0.01 day-1
F.Mayet et al. Nucl. Inst. M.eth. A 455 (2000)
554
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 20
21?? detection phenomenology
- SUSY model phenomenological MSSM
- 6 free parameters
- M2, ? jaugino and higgsino mass parameters
- m0 common scalar mass
- MA pseudo scalar Higgs mass
- tan ? Higgs vev ratio
- At,b trilinear couplings
- DarkSUSY code, large SUSY scan 2.106 models
- Parameters Min Max
- ? (GeV) 50 103
- M2 (GeV) 50 103
- m0 (GeV) 100 104
- MA (GeV) 100 103
- tan ? 3,10 and 60
- At,b 0
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 21
22? Sensivity area MACHe3/scalaire
F. Mayet et al. Phys. Lett. B 538 (2002) 257
- for ? lt 0 scalar interaction is suppressed
- this is not a general trend!
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 22
23? Comparison with indirect detection ?
- ?(Earth) ? ?scal non correlated
- ?(Sun) ? ?scal and ?spin complementarity
F. Mayet et al. Phys. Lett. B 538 (2002) 257
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 23
24? Sensitivity area MACHe3/?
F. Mayet et al. Phys. Lett. B 538 (2002) 257
- ? telescope sensitive to higher masses
- large SUSY region is reached
E.MOULIN 4th Marseille Internat. Cosmology
Conference 24/06/03 24