Feasibility%20Check%20/%20How%20to%20test - PowerPoint PPT Presentation

About This Presentation
Title:

Feasibility%20Check%20/%20How%20to%20test

Description:

What should be checked experimentally and with simulation (if possible) ... One Larmor precession of the electron in B1 : (?JB1)-1 ~ sec ... – PowerPoint PPT presentation

Number of Views:14
Avg rating:3.0/5.0
Slides: 10
Provided by: sak71
Category:

less

Transcript and Presenter's Notes

Title: Feasibility%20Check%20/%20How%20to%20test


1
Feasibility Check / How to test
Polarized 3He ion source / Polarized 6Li ion
source
  • What should be checked experimentally and with
    simulation (if possible)
  • Depolarization in the ionizer inject
    polarized 3He gas supplied by (1) Polarized
    Target at RCNP or (2) LKB, Paris
  • Ionization efficiency inject 4He gas / detect
    2 ions
  • Detailed study of ionization mechanism

Feasibility check experiment
ECR ionizer Ionization complicated
multi-step
Polarized 3He atoms
Polarized 3He2 ion
Polarimeter
( Polarization Pi, Intensity Ii )
( Polarization Pf, Intensity If )
NMR
  • Delivered from Mainz to Sheffield in 2001
  • magnetized spin box
  • Housing a glass vessel
  • Relaxation time 50 hours (reproducibly ?)

Theoretical / Simulation evaluation
Equipments Status Cost Date Comments Contact
Polarized 3He atoms Cell for transfer design / LKB, Paris/Mainz Ssp m.e. optical pumping Prof. Tastevan
Polarized 3He atoms Shimizu Target at RCNP Spin exchange
ECR Ionizer Exists HIPIS 2.45GHz
Connection to ECR Need drawings etc around ECR Magnet for Holding field
Polarimeter for atoms NMR
Polarimeter for ions Beam course / When ?
Readout/DAQ/Control Should be prepared
Feasibility test 1 Depolarization 2003 end BPAC / Possible schedule to install 3He cell etc..
Feasibility test 2 Ion collection efficiency with 4He/6Li 2003 end BPAC / What should be prepared ?
2
Critical Field to keep polarization
Hyper Fine Interaction
Weak magnetic field
Strong magnetic field
?(MHz) Bc(Gauss) 1H 1422.6 508.2 3He 8669.4 309
7.1 6Li2 8479.2 3029.1
ECR ion source 2.45 GHz 875 Gauss 10 HGz
3571 Gauss
3
Depolarization Mechanism
Magnetic Field B
Ion confinement time tconf
Micro Wave
10 msec at 10 GHz (ANL)
  • Ionization process / Electron Capture and FI/HFI
  • 3He ? 3He e- depolarization with HFI
  • 3He ? 3He e- no depolarization
  • 3He e- ? 3He depolarization with HFI
  • 3He e- ? 3He ? 3He h? depolarization
    due to HF (LS coupling)
  • Spin Flip due to Electron Spin Resonance (ESR)
    and HFI
  • 3He µ wave ? ESR transition electron spin
    flip HFI only ECR resonance zone
  • Others

Electron Cyclotron Resonance
Electron Spin Resonance
4
Results on depolarization (1) full effects
Polarized 3He atoms polarization 50
  • Includes depolarization due to
  • Ionization / capture process
  • Spin flip with ESR and HFI
  • Occurred any place in ECR plasma
  • Can be seen
  • High ECR frequency
  • confinement time long
  • ionization process many times
  • Low vacuum
  • electron capture
  • low polarization
  • Others

Polarization
ECR frequency (GHz)
5
What should be considered carefully
  • Spin flip due to ESR
  • ESR only at ECR resonance field region at
    BB0mwECR/e
  • RF magnetic field B1 due to micro wave
    randomly oriented
  • B1max (2u0s/c)1/2 s pointing vector for
    microwave RF power
  • B1 very small
  • One Larmor precession of the electron in B1
  • (?JB1)-1 µ sec
  • Time to pass Resonance zone (10 um / 105 cm/s
    1 ns)
  • Too short to flip the spin of electron
  • Can be neglected
  • 2. Confinement time Depolarization in
    Ionization Process
  • 3. Polarized He gas transfer from ECR Loss Cone
    confinement time
  • 4. Others

6
Results on depolarization (2)
Polarized 3He atoms polarization 50
Remove ESR effects Include ionization process
Recover polarization thanks to ESR effects
neglect High ECR frequency long confinement
time dominant process ionization
Polarization
High vacuum
Low vacuum
ECR frequency (GHz)
7
Results on depolarization (3)
Polarized 3He atoms polarization 50
  • Comparison
  • Confinement time 1 msec blue
  • Confinement time 10 msec red
  • Without ESR effects
  • High vacuum
  • Possible to realize high polarization
  • with reduction of confinement time
  • by the adjustment of mirror ratio of
  • ECR ionizer

Polarization
High vacuum
Low vacuum
ECR frequency (GHz)
8
Results (3)
9
What should be done Next
  • Understand the Depolarization mechanism
  • Consider / evaluate each depolarization process
    carefully
  • Polarization estimation obtained by existing ECR
    (HIPIS)
  • Idea to Overcome the depolarization
  • (1) Straightforward high polarization 3He atom
    short confinement time high polarization
    low intensity
  • (2) Nice Idea .. should be considered
  • Preparation to measure the depolarization /
    feasibility test
Write a Comment
User Comments (0)
About PowerShow.com