Acquisition of 1second data in IPGP magnetic observatories - PowerPoint PPT Presentation

1 / 11
About This Presentation
Title:

Acquisition of 1second data in IPGP magnetic observatories

Description:

New, low-noise fluxgate magnetometers will have to be developed. ... Instrumental noise. Test of the magnetometer in a non-magnetic room in Chambon la For t ... – PowerPoint PPT presentation

Number of Views:52
Avg rating:3.0/5.0
Slides: 12
Provided by: geoma
Category:

less

Transcript and Presenter's Notes

Title: Acquisition of 1second data in IPGP magnetic observatories


1
Acquisition of 1-second data in IPGP magnetic
observatories
  • A. Chulliat, J. Savary, K. Telali, X. Lalanne

2
Motivations
  • To provide data with the same characteristics as
    magnetometer chains (such as IMAGE, CANOPUS, GMC,
    etc.) for studying rapid variations of external
    origin.
  • Ionospheric and magnetospheric electrical current
    systems
  • ULF waves
  • To be synchronized with magnetic satellites such
    as Ørsted, CHAMP and the upcoming Swarm.
  • INTERMAGNET recommended the production on
    1-second data in 2003 (Dourbes meeting).
  • Today more and more observatories are producing
    one-second data and INTERMAGNET is setting up the
    capability to distribute these data in quasi-real
    time.

3
Requirements
  • Requirements 1-3 come from Jeff Loves survey
    (2005). Some users would like to have a better (1
    ms) time accuracy.
  • Requirement 4 cannot be fully satisfied with
    existing fluxgate magnetometers. New, low-noise
    fluxgate magnetometers will have to be developed.

4
The IPGP 1-second system
5
Upgraded magnetometer
  • The VM391 fluxgate magnetometer has been used
    for about 15 yrs in IPGP observatories. It is
  • ring-core
  • triaxial
  • homocentric

IPGP VM391
  • Upgrades made in 2008
  • Changes in the analog part of the electronics
    (integrator, amplifiers)
  • cutoff _at_ 2Hz
  • 10 ms time accuracy
  • Design and implementation of a new 24-bits ADC
  • 10 pT resolution

6
Frequency response (amplitude)
2 Hz cut-off
X Y Z
dB
The frequency response is obtained by submitting
the magnetometer to a sinusoidal magnetic field
at a known frequency in a cylindrical coil.
Hz
7
Frequency response (phase)
2 Hz cut-off
lt 10 ms
X Y Z
ms
130 ms
Hz
8
Instrumental noise
Test of the magnetometer in a non-magnetic room
in Chambon la Forêt
Geomagnetic variations in CLF
10 pT/vHz _at_ 1 Hz
0.3 Hz
9
New data acquisition system
  • A new data acquisition system, ENO3, has been
    developed and is now running in CLF.
  • GPS synchronization
  • Time delay correction
  • Configuration via a web interface
  • Data collection in ascii format
  • Data transmission via the internet
  • Control screen

10
Gaussian digital filter
  • 15 points filter, centered on UT sec
  • Requirements
  • sampling frequency fs 5 Hz
  • cutoff frequency fc 0.3 Hz
  • smallest coefficient 0.01

where
0.3 Hz
11
Summary
  • The upgraded IPGP VM391 magnetometer has the
    following characteristics
  • 2 Hz cutoff frequency
  • 10 ms time accuracy
  • 10 pT resolution
  • 10 pT/vHz _at_ 1 Hz noise
  • A new, low-noise sensor will have to be developed
    if one wants to achieve a lower instrumental
    noise.
  • The new ENO3 data acquisition system acquires
    data at 5 Hz and applies a Gaussian digital
    filter with cutoff at 0.3 Hz to produce 1-second
    data.
  • The new 1-second system will be installed in
    other IPGP observatories and observatories in
    cooperation.
Write a Comment
User Comments (0)
About PowerShow.com