COMARRA - PowerPoint PPT Presentation

1 / 17
About This Presentation
Title:

COMARRA

Description:

Next generation STM-1/4/16 Platform. Extensive Support for Data traffic ... Audio-visual indication of alarms through Hooter and LEDs ... – PowerPoint PPT presentation

Number of Views:39
Avg rating:3.0/5.0
Slides: 18
Provided by: comarra
Category:
Tags: comarra | hooter

less

Transcript and Presenter's Notes

Title: COMARRA


1
COMARRA
Telecom Transmission Solutions
VCL100MC-16 Next Generation STM-1/4/16 Platform
Updated Jan, 2007
2
VCL100MC-16
  • Next generation STM-1/4/16 Platform
  • Extensive Support for Data traffic
  • FE GigE transport over VC12s/VC3s/VC4s
  • Ethernet Switching/VLAN switching
  • High Density Platform
  • 567xE1 from a single chassis
  • 8 STM-1 rings subtended from 1 STM-16 ADM
  • 2 STM-4 rings subtended from 1 STM-16 ADM
  • High capacity
  • 7.5Gig fully non blocking XC at VC12 granularity
  • Managed by the same NMS as other VCL100 platforms
    (VCL-NMS)

3
VCL100MC-16 Line Diagram
4
Common ModulesCross Connect and Controller Card
(XCC)
  • XCC provides following functionalities
  • Cross Connect matrix
  • Fully non-blocking VC-12/VC-3/VC-4
  • 7.5Gig (48x48 STM-1/OC-3 equivalent)
  • 12.5Gig (80x80 STM-1/OC-3 equivalent) will be
    available in future
  • Unidirectional, Bidirectional, Multicast and
    Broadcast
  • Control Sub-system
  • Architected to support dense cross connect
    configurations
  • High processing capability to handle control
    plane loads in large DXC locations
  • Can handle multiple subtended rings
  • Timing Sub-system
  • Timing can be derived from
  • External inputs 2MHz or 2Mbps
  • STM-1/4/16 or OC-3/12/48 and E1 Interfaces
  • Internal Stratum-3 clock
  • SSM support on S1 byte

5
Power Supply Module
  • PSM takes - 48 V DC as input and provides - 5 V
    - 12 V DC to other subsystems. It has the
    following features
  • - 36 V DC to - 60 V DC operation
  • Reverse Polarity protection
  • Automatic shutdown when power exceeds - 60 V or
    falls below -36 V
  • No impact on operation for power interruption lt
    4ms
  • Inrush limiting as per ETSI EN 300 132-2
  • Redundancy of Power Supply
  • Fuse protection in case of overloads/failures.

6
Multi-function Card (MFC)
  • MFC provides the following
  • NMS (10/100Base-Tx)
  • Craft (RS-232)
  • F1 user channel and Modem interface (RS232)
  • Engineering OrderWire
  • Audio-visual indication of alarms through Hooter
    and LEDs
  • Seven External Alarm inputs and four Potential
    free contacts for alarm outputs

7
Traffic Modules
  • Optical Cards
  • 1xSTM-16
  • SFP Based
  • 2xSTM-4 / 8xSTM-1 card
  • SFP Based. Individual STM-1/4 Ports can use
    different SFPs
  • A contiguous block of four STM-1s can be
    upgraded to a single STM-4
  • Mix and match STM-1 o/e up to one STM-16
  • Data Cards
  • 8x10/100BaseT Ethernet Transport Card ( STM-1
    backhaul)
  • 4x10/100BaseT and 4 x 100BaseFX Ethernet
    Transport Card ( STM-1
  • backhaul)
  • 2xGigabit Ethernet Transport Card (STM8
    backhaul)
  • 8xFE 2xGigE Ethernet Switching Card (STM4
    backhaul)
  • 8xFE 2xGigE Ethernet Switching Card (STM8
    backhaul)
  • PDH Cards
  • 63xE1
  • 3xE3/DS3

8
Hardware Features
  • Higher Tributary Density
  • VCL100MC-16 can drop up to 567xE1s from the
  • chassis using 63xE1s tributary cards
  • Subtended Rings
  • VCL100MC-16 can function as a stand-alone
  • cross connect subtending
  • 8xSTM-1/OC-3 rings OR
  • 2xSTM-4/OC-12 rings OR
  • And
  • 1xSTM-16/OC-48 rings
  • All configurations with full VC-12/VT1.5
  • cross connects possible between the rings

STM-1/OC-
3 Ring
2xSTM-4/OC-12 rings
9
VCL100MC-16 Bandwidth Distribution
  • 7.5G XC
  • Slot 6 and 11 are serial slots with maximum
    uplink of STM-8 each
  • Slots 2-5 and 12-14 are parallel slots with
    maximum uplink of STM-1 each
  • Total uplink from all tributary slots
    (slots 2-6 and slots 11-14) can be STM-16
  • 12.5G XC (in future)
  • Slots 2-5 and 13-14 can be serial slots with
    maximum uplink of STM-4 each and slots 6,11,12
    can be serial slots with maximum uplink of STM-8
    each
  • All trib slots can be parallel slots with maximum
    uplink of STM-1 each
  • Total uplink from all tributary (slots 2-6 and
    slots 11-14) can be 3 x STM-16

10
VCL100MC-16 Application Diagram
STM-1 Ring
STM-1 Ring
STM-4 Ring
VCL100MC-16
VCL100MC-16
STM-16
FE, GE
DSLAM Aggregation
VCL100MC-16
10/100 Base-T FE, GE
VCL100MC-16
VCL100MC-16
10/100 Mbps Ethernet
Drop up to 567 E1/DS1 for Wireline and Wireless
Backhaul
  • Ethernet Services for Corporate Customers
  • Ethernet Private Line
  • Ethernet Virtual Private Line
  • Ethernet LAN

11
Network Protection
  • Support for all standard and emerging network
  • protection features such as
  • 11 MSP
  • SNCP
  • 2F MS-SPRing
  • LCAS Protection for Ethernet
  • RSTP Protection with Ethernet switching.

12
Equipment Protection
  • VCL100MC-16 can offer redundancy to
  • Power Supply Module (PSM)
  • 11 hot standby and load-sharing modes
  • Cross Connect (XCC)
  • Control Sub-system
  • Integrated within the Cross Connect (XCC)
  • Optical Cards (Using MSP or SNCP)
  • Timing sub-system Interfaces

13
Multi-service Support
  • Supports FE GigE Interfaces and Layer 2
    switching
  • Complies to the latest ITU-T Recommendations on
    transport of EoS
  • G.7041 (GFP)
  • G.7042 (LCAS)
  • G.707 (Virtual Concatenation)
  • 10/100BaseT interfaces can be mapped to both LO
    (VC-12/VT1.5) and HO (VC-3/STS-1 and
  • VC-4/STS-3) virtual containers
  • Gigabit Ethernet traffic is mapped to HO virtual
    containers
  • Layer 2 Switching complies to IEEE 802 standards
  • IEEE 802.1D (Bridging)
  • IEEE 802.1Q (VLAN)
  • Also IEEE 802.1p (priority)
  • IEEE 802.3x (Flow Control)
  • IEEE 802.1w (Rapid STP), 802.1s (Multiple STP)
  • IEEE 802.3ad (link aggregation)
  • IEEE 802.1ag (Connectivity fault management)
  • MEF 9 MEF 14

14
Software Features
  • Software intelligence is a key differentiator of
    VCL100MC-16 as also of all other VCL100 platforms
  • Some advanced features which are typically
    associated with high-end DWDM platforms are
    provided on VCL100MC-16
  • Auto topology discovery
  • G.7714
  • Customer Network Management
  • Provision for the customer to self-provision
    circuits over his part of the VCL100 network
    using standard web browser interfaces
  • Northbound SNMP ensures seamless integration with
    third party EMS

15
Management Connectivity
  • VCL100MC-16 has a wide range of management
    options to effectively inter-operate with other
    vendor equipments in mixed deployment scenarios.
  • DCC-R
  • DCC-M
  • F2/F3 bytes
  • E1/VC12 management channel
  • Dial-in using modem port
  • Ethernet Management.
  • DCC transparency
  • DCC-R, DCC-M, F1, F2/F3 can be passed through,
    permitting third party nodes to co-exist in the
    same ring.

16
Sweet-Spots for VCL100MC-16
  • Optimized for a variety of stand-alone ring
    Point-of-Interconnect (PoI) applications
  • Consolidation of the PoI infrastructure by
    integrating
  • Multi-rate Optical Interfaces (STM-1/4/16)
  • Can be positioned as a versatile gateway element
  • Support for SDH interfaces
  • Support for both AU3 and AU4 mapping modes
  • ADM applications with subtending rings
  • Each ring can be protected using a different
    protection scheme
  • Say, SNCP on one ring, MS-SPRing on another
  • Support for large E1,E3/DS3 traffic add-drops
  • Wave feeder for DWDM networks due to support for
    15xx nm interfaces

17
Thank you for your attention
For more details visit us at our Website
at http//www.comarra.co.uk
123 Springvale Road, Winchester HantsSO23 7LE
UKPhone 44 (0) 20 7871 9524E-mail
info_at_comarra.co.ukWeb Site http//www.comarra.co
.uk