Title: Iridium Data Transfer from North Pole Deployed
1Iridium Data Transfer from North Pole Deployed
Ocean Flux Buoys Tim Stanton Oceanography
Department, Naval Postgraduate School
2OVERVIEW
- Flux buoy objectives
- Data transmission requirements
- Hardware Design
- Sampling design
- Iridium Transmission protocol
- Testing / Evaluation
- Sample statistics
- Summary
3- SCIENTIFIC OBJECTIVES
- Measure turbulent stresses and
- heat fluxes in the ocean mixed layer
- Use direct eddy-correlation techniques
- ltuw,vwgt, ltwTgt
- Return both mean, spectral
- covariances, and scalar spectra to
- look at turbulent length scales
- Optionally bring back raw (4 Hz) sensor
- data sections for QC, sensor evaluation
- and other analyses
- Measure over at least annual cycles with
- selectable sampling (typically 45 minutes
- every 3 hours
4Data Transmission Requirements
- 2-way coms to provide
- Adaptable sampling strategies
- Selectable power conservation
- Sampling experiments
- Remote diagnostics of sensors and processor
system - 20 to 200 Kbytes / day data transmission
- Return basic buoy status, position, ice velocity,
mean fluxes - Return selected raw data blocks of (u,v,w,T,S)
- Fallback to summary messages via Argos
5- Hardware Design
- 8 port switched power
- RS232 main processor
- Iridium modem (primary,
- 2-way comms)
- Argos ptt (secondary, 1 way)
- Snow / ice / cold tolerance
-
6Main Buoy Electronics 68332-based
controller (Onset Model 8) High efficiency, low
noise switched- mode power supplies for each of
8 ports Both solar panel/gell cell and 450 AH,
10.5 volt lithium battery pack support NAL
9500 Iridium modem
7Sampling Design
- Remote selection of data types to output
- Remote selection of sample intervals, sample
duration, sub-intervals for flux estimation and
reporting intervals - Remote programming of sample-doubling threshold
(eg if currents exceed 15 cm/s, half the off-time - Remote monitoring of buoy performance parameters
including battery voltages, mean and peak current
consumption, upper and lower buoy internal
temperature - Settings and monitor values updated with every
data transmission (typically 2/day)
8Data Communication Solution (2001 design)
- Iridium direct dial-in to a NPS workstation
- Quick connect, low overhead protocol
- Relatively simple software design
- Under local control (early days of Iridiums
come-back) - Build in tolerance to no connects, dropped
connects - Build in a hand-shaking block by block data
transfer protocol - Large rotary buffer for outbound blocks to
overcome service drops - Fall-back to one way, summary data transfer via
Argos
9(No Transcript)
10Testing / Evaluation
- As usual, short testing cycle before the first
NPEO deployment - Needed to evaluate the main processor / power
board, NAL modem and the 3000 line main program - End to end test sequences of pseudo-data to
establish connect and dropped connect performance - Needed nearly open horizon conditions to simulate
ice-deployed conditions - Extreme cold performance tested with a cryogenic
freezer on top of our building (still there) - Difficult to test long fall-back protocols
11Iridium Data Transfer Performance
- Statistics for a 6 month period on the 2003 buoy
- Dial-in success rate 94.9
- Of 350 connect attempts, 325 had full data
transfer success, 12 had no successful data
transmission, 13 transmitted at least 1 data
block. - 93 of calls were fully successful, 7 had
dropped calls - Effective throughput on 25Kbyte transfers was
1979 baud - Effective baud rate on 132Kbyte transfers was
2949 baud
12Full buoy drift since the April 2002 deployment,
and the winter mix-down
13SUMMARY
- Iridium is an excellent solution for the 20-200
Kbyte / day - data transfer requirement in polar regions
- The direct dial-in protocol was quick to develop
and effective, but does not scale well to large
deployments - Two-way coms exploited to provide adaptive
sampling and diagnostic capabilities - Care needed with snow/ice covering of the antenna
- It would be great if there were a slow-charge
method for the super capacitor in the 9500 This
is an unnecessary burden on batteries / switchers
at turn-on.