1
Mobile Conductivity Assessment System (MCA) used
for canal seepage surveys
GPS
EM-31
On-board LAPTOP
2
Canal survey (Losthills)
3
EM-31
4
(No Transcript)
5
(No Transcript)
6
Canal surveys
  • Study location Lost Hills Water District, Kern
    County, CA. (Unlined section area 5 North ditch,
    about 3,700 ft long).
  • Study period August 2001 when canal was open.
  • Canal surveys A Mobile Conductivity Assessment
    (MCA) System was developed that comprised four
    components mounted on a truck (1) an
    electromagnetic induction sensor EM-31, (2) a
    global positioning system (GPS) receiver, (3) a
    computer, and (4) a hydraulic soil sampler (Fig.
    1). The EM sensor was placed in a plastic
    carrier-sledge attached to the rear of the truck
    and measured the depth-weighted apparent soil EC
    down to 10 ft. The EM and GPS instruments were
    connected via digital interfaces to an on-board
    laptop computer that simultaneously recorded the
    EM readings and their corresponding GPS locations
    using a Salinity surveyor software (US
    Positioning, NM).

7
Canal surveys (cont.)
  • Electromagnetic induction principle the EM
    transmitter coil induces an electromagnetic field
    in the ground, which in turn creates a secondary
    magnetic field that is measured by the receiver
    coil. The ratio of both fields provides a
    measure of the depth-weighted apparent electrical
    conductivity (EC) in a volume of soil below both
    coils. Since EC of a soil is a function of its
    water content, salt content, texture, use of the
    EM technique can be very valuable for canal
    seepage assessment.
  • Data calibration and analyses using ESAP-95
    statistical package following ground-truthing
    soil sampling (0-8 ft). Soils were analyzed for
    EC, bulk density, water content, and texture.
  • Output data Contour maps of soil EC and water
    content, and clay content using ArcView GIS.

8
Mobile Conductivity Assessment System
(MCA) used for salinity surveys
GPS
Laptop
EM-38 placed in a plastic sled
Hydraulic soil sampler
Spray Coupe
9
Geonics EM-38 Dual Dipole Conductivity Meter
Unit in vertical dipole mode
Unit in horizontal dipole mode
Serial RS232 digital interface to connect EM
meter and computer
10
Salinity distribution 0-1 ft (1st field)
11
Salinity distribution 0-1 ft (2nd field)
Write a Comment
User Comments (0)
About PowerShow.com