Timing Properties of T0 Detectors At PHOBOS - PowerPoint PPT Presentation

1 / 15
About This Presentation
Title:

Timing Properties of T0 Detectors At PHOBOS

Description:

Collisions of Au-Au, d-Au and ... Hadrons, such as K, p, p, produced in collision are detected. ... Ten detectors in a ring on either side of collision point. ... – PowerPoint PPT presentation

Number of Views:19
Avg rating:3.0/5.0
Slides: 16
Provided by: saba
Category:

less

Transcript and Presenter's Notes

Title: Timing Properties of T0 Detectors At PHOBOS


1
Timing Properties of T0 Detectors At PHOBOS
  • Saba Zuberi,
  • Erik Johnson, Nazim Khan, Frank Wolfs, Wojtek
    Skulski
  • University of Rochester

2
OUTLINE
  • Brief introduction to PHOBOS
  • Particle ID and why the timing properties of T0s
    are important?
  • Time of Flight (TOF) Detector
  • Dependence of timing resolution on voltage and
    position of incident particles
  • Results
  • Summary

3
RHIC Little Big Bang on Long Island
  • Two rings 2.4 miles long.
  • Collisions of Au-Au, d-Au and p-p studied.
  • Ions have energies of up to 100GeV/nucleon for Au
    and 250GeV/nucleon for p.
  • Bunches of billions of particles travel with
    speeds up to 0.99995c.
  • Matter formed in head on collisions reaches
    temperatures of 1012 oC in region of diameter
    10-14m.

4
RHIC Physics Goals
  • At everyday energies the basic building blocks
    of matter, quarks and gluons are confined in
    hadronic matter.
  • At RHIC energies, quarks and gluons become
    deconfined and the formation of Quark Gluon
    Plasma (QGP) is potentially possible. QGP is
    believed to have existed microseconds after the
    Big Bang.
  • New phase of matter is expected to last for
    10-23sec.
  • Hadrons, such as K, p, p, produced in collision
    are detected.
  • Properties of expected phase transition of matter
    inferred from particles produced.
  • PHOBOS Physics Aim To investigate properties of
    hadron
  • production at extreme energy densities.

5
PHOBOS Detector
6
Particle ID and Time Of Flight
  • Low momentum particles (eg.pplt55MeV/c,
    pKlt135MeV/c)
  • Stopped in Spectrometer arms.
  • Identified from dE/dx and ETOT.
  • Higher momentum particles
  • Enter magnetic field and momentum measured.
  • Identified from dE/dx and p
  • (eg. p/K separation 0.6GeV/c)
  • High momentum particles
  • Reach the TOF walls.
  • Momentum and TOF allows mass of particle to be
    calculated.

7
Extension of Particle ID to High Momentum Region
TOF detector extends particle ID to higher
momentum region.
  • Timing Resolution, sTOF, of TOF must be smaller
    than the difference in the time-of-flight in
    order to distinguish between particles of
    different mass with same momentum.
  • Timing resolution of TOF, sTOF, limits momentum
    range of particle identification.
  • Require timing resolution of TOF, sTOF100ps.

With TOF p/K separation 0.6GeV/c to 1.2GeV,
K/p separation 1.2Gev/c to 2GeV
(L1.7m,sTOF100ps)
8
Determining Time-of-Flight
  • T0 counters determine time of collision
  • TOF Wall determines time of arrival.
  • Accuracy of arrival time and collision time
    measurements determine sTOF.

9
TOF Walls
T0 Detectors
  • Cerenkov radiators, 50mm in diameter, coupled to
    fast PMTs.
  • Cerenkov radiation is produced when charged
    particles in a medium have a velocity faster than
    the speed of light in that medium.
  • Ten detectors in a ring on either side of
    collision point.
  • Can determine the collision point to within 50mm.
  • Each TOF wall consists of 120 scintillation slats
    0.8x0.8x20cm3, coupled to two PMTs (top and
    bottom).
  • Position of incident particles is determined and
    allows spectrometer tracks to be matched with TOF
    hits.

T0 Counters installed at RHIC
TOF Wall installed at RHIC
10
Photomultiplier Tubes
  • PMT
  • Photoelectron is emitted when cathode is struck
    by photon.
  • Dynode chain accelerates and amplifies current as
    secondary electrons are emitted
  • Final signal collected from anode.
  • PMT Time Resolution depends on
  • Variation in transit time of electrons through
    tube
  • Fluctuations due to statistical noise.
  • Gain is the amplification factor of the PMT.
  • Gain depends on number of dynodes in chain and a
    secondary emission factor. GK?V?n

http//laxmi.nuc.ucla.edu8248/M248_99/autorad/Sci
nt/pmt.html
T0 detector
11
Dependence of T0 Timing Resolution on Supply
Voltage
Dependence of T0 Timing Resolution on Position of
Incident Particles
  • For larger supply voltage, T0 detectors have
    larger gain and provide larger signals.
  • Expect timing resolution, sTO to improve with
    increased voltage.
  • To avoid saturation of PMTs operate at as low a
    voltage as possible without sacrificing sTO.
  • Determine dependence of T0 timing resolution, sTO
    on supply voltage and optimum operating voltage.
  • Possible non-uniformity due to
  • Cerenkov radiator
  • Optical grease coupling the radiator to the PMT
  • Geometry of T0 detector
  • This may lead to variation in sTO depending on
    position of incidence.

12
Experimental Setup
  • Timing properties were studied using cosmic rays.
  • Two 0.8x0.8x0.8cm3 plastic scintillating
    detectors used to confine position of incidence
    and provide start time in timing measurements.
  • Supply voltage of the start detectors is kept
    constant and T0 voltage is varied.
  • Position scan conducted in two ways
  • Diameter Scan
  • Circumference Scan
  • The vertical distance between the detectors
    remained constant.

13
Result Timing Resolution vs. Supply Voltage
  • Timing resolution improves with increased voltage
    up to -2700V.
  • At -2700V achieved a 55ps resolution.
  • The testing system has an intrinsic resolution of
    50ps.

14
Result Timing Resolution vs. Position of
Incident particles
  • No significant variation in T0 timing resolution
    was observed either across the diameter of the
    detector, or around its circumference.

Circumference Scan
Diameter Scan
15
Summary
  • The timing resolution of the TOF subsystem limits
    the particle id capabilities in high momentum
    region.
  • The T0 timing resolution is found to have little
    dependence on the position of incident particles.
  • Verified that the most effective operating
    voltage for the T0s is -2700V, where sT0 55ps.
  • Beyond 2700V the supply voltage does not
    influence the timing resolution of the T0
    counters.
Write a Comment
User Comments (0)
About PowerShow.com