LSS Detectors - PowerPoint PPT Presentation

1 / 14
About This Presentation
Title:

LSS Detectors

Description:

Pixel size: 0.04mm in spectrum direction. 0.04mm in imaging direction. Format: FUV: 2390 150 pixels. Area: 96mm 6mm. NUV: 2650 150 pixels. Area: 106mm 6mm ... – PowerPoint PPT presentation

Number of Views:25
Avg rating:3.0/5.0
Slides: 15
Provided by: del64
Category:
Tags: lss | detectors

less

Transcript and Presenter's Notes

Title: LSS Detectors


1
LSS Detectors
  • Qian Song
  • NAOC
  • Sq_at_bao.ac.cn

2
Optical design of the LSS
  • Specifications
  • Wavelength coverage
  • FUV 102 170 nm
  • NUV 165 320 nm
  • Spectral resolving power
  • 1500 2500
  • Slit width 1''
  • Slit length 75''
  • Spatial resolution 1''
  • Maximum throughput and reliability (minimum
    number of reflecting surfaces, no movable
    elements)
  • Optical layout for FUV is based on Rowland
    circle, only one optical element between the
    entrance slit and the detector. The grating
    serves as both the light dispersing and imaging
    element.

3
Requirements of detectors
  • Pixel size 0.04mm in spectrum direction
  • 0.04mm in imaging direction
  • Format
  • FUV 2390150 pixels
  • Area 96mm6mm
  • NUV 2650150 pixels
  • Area 106mm6mm
  • Image is curved when no rectifier mirror is
    applied (only a grating)

4
Detector MCP Anode photon counter
  • Photocathode
  • CsI, KI, CsBr, Kbr (FUV)
  • CsTe, Cs2Te, RbTe2 (NUV)
  • New AlGaN DQE 50 (100 360nm)
  • Anode
  • WSA, vernier

5
Dates of delivery of scientific instruments
modelsrequired by Lavochkin assuming a 2010
launch date
  • Full-size mass model
  • 05.2008
  • Thermal equivalent
  • 01.2009
  • Engineering model
  • 01.2009
  • Flight model
  • 05.2009

6
Schedule Proposed to CNSA
  • Phase A/B1 (technical feasibility and baseline)
  • 2007.11
  • Now targeting at 2008.03
  • Validation model
  • 2007.11-2009.06
  • Flight model
  • 2009.07-2010.10
  • Launch
  • Target at early 2012.
  • A 2012 date has been formally requested by CNSA
    to Roscomos in June 2007. Roscosmos is
    evaluating.

7
LSS Detector Deliverables Schedule requirements
  • Detector dimension, mass, thermal properties,
    structural and thermal design should provided
    before 2008.11
  • To allow 2 months to meet thermal model delivery
    date of LSS to Lavochkin (2009.01)
  • Detector functionality and performance validated
    no later than 2009.06
  • So that LSS design can be validated before Flight
    Model Phase
  • Detector flight model no later than 2010.04
  • To give 6 months of AIV time to LSS, and 12
    months of AIV time to WSO
  • All dates are TBC

8
A Development Outline Plan by SRC
  • Typical Detector and Electronics resource
    requirements
  • Dimensions (mm) length x width x height
  • Assume typical intermediate active detector
    size 115 x 15
  • Detector stack active dimensions 15mm 130 x
    30 x 25
  • Vacuum enclosure detector 30, 30, 15mm
    (l,w,h) 160 x 60 x 40
  • Vacuum door footprint 160 x 60(requires
    accommodation after opening)
  • Ion pump (below detector?) TBD
  • Mass grams
  • Electronics 300-400
  • Electronics box 400-500
  • Detector 200-300
  • Vacuum enclosure (s/s) inc. door and
    mechanism 600-800
  • Ion pump 400-500
  • Total 1900-2500 g
  • Power mW
  • Front end electronics 400-600
  • Digital electronics 600-900
  • Data communications 1200-1800
  • High voltage PSU 300-500

9
A Development Outline Plan by SRC
10
Model policy usual in China
  • Proto model (functional model) has all the
    functions, mass, size, mechanical, thermal almost
    settled, the whole design is almost the final
  • Qualification model all the qualification tests
    and evaluations done.
  • Flight model rebuild from qualification model
    into space use. Adequate tests.

11
A good news
  • The first batch of funding is expected to be
    arriving in 1 or 2 months.
  • The funding is to support the LSS proto model
    development. The required schedule is far behind
    WSO required schedule.

12
New comer XIOPM
  • The Xian Institute of Optics and Precision
    Mechanism has jointed the LSS team and they may
    provide some design and manufacture support in
    the LSS detector development, especially the
    manpower. This may help to speed up the going.

13
A WSA photon counter by XIOPM
original
corrected
14
Thanks
Write a Comment
User Comments (0)
About PowerShow.com