1
GAS ANALYSIS OF NITRITE LABORATORY
DISCUSSION NO2-(aq) H (aq) NH2SO3- (aq) ?
N2(g) HSO4- (aq) H2O(l) Ptot P of N2 P
of H2O SCHEDULE WEEK 1 (Learn
technique) Experiment set-up (leak tests,
determining amount of sample) First runs with
unknown nitrite sample Estimate precision of
results (5 successive runs agree ?V(N2)/msmpl
1) WEEK 2 (Apply technique) Do runs until
precision achieved. Boil 1L of deionized water
for 10 minutes, allow to cool without agitation,
then transfer to 1 L bottle. CO2 free water for
use in preparing NaOH solution for next
experiment. Report due next day.
2
  • SAMPLE PRECAUTIONS
  • Unknown from stock desiccator
  • Transfer to transport desiccator
  • Write down sample number
  • Weigh only 1 sample at a time
  • Use gelatin capsules
  • Return unknown vials to stock desiccator at end
    of period
  • Estimate size of unknown
  • 70 NaNO2
  • 730 torr, 295K, 35 mL

3
Keys to Procedure!!!
  • Before connecting the Erlenmeyer with the sample,
    raise leveling bulb until levels equalize with
    the buret reading near 0 mL and only 2-3 cm of
    water showing in the leveling bulb.
  • Connect the Erlenmeyer carefully but firmly.
  • Adjust buret and bulb water levels until they are
    the same. Read buret volume.
  • Measure the temperature of the bath and the
    temperature of air near the top of the buret (for
    PV nRT). Make sure thermometer is dry for the
    air measurement.
  • Lower leveling bulb before starting reaction.

4
  • THINGS TO REMEMBER
  • Measure barometric pressure one time each week.
    Barometer located near ovens.
  • Before connecting Erlenmeyer, adjust leveling
    bulb so that buret is near 0 mL

  • and leveling bulb is only 2-3 cm full
  • Only read volume when buret level even with
    leveling bulb level
  • If bath ?T gt 0.1ºC at end of run, use ice chips
    to equalize temperature before

  • reading
    final volume
  • Adjust mass sample to achieve approximately 35
    mL change in volume
  • At days end, turn in "kit", replace transfer
    desiccator, put unknown vial storage


  • desiccator
  • In write-up, use v. p. of water at your T to
    subtract water P from total P

5
CHANGES FROM LAB MANUAL Step 4 Add sulfamic
acid and then the capsule. Shake periodically.
The capsule does not dissolve immediately. Step
5 Measure T of water in the bath and
T of air near the buret (with dry
thermometer!!!) Use bath T to determine v. p. of
water. Use air T in PVnRT to determine
moles N2 from PN2
6
WEEK 2 Do runs until precision achieved.
Boil 1L of deionized water for 10 minutes w/
boiling chips Allow to cool without
agitation, then transfer to 1 L bottle. CO2
free water for use in preparing NaOH solution for
next experiment.
  • .

7
Cooling StorageLab assistant add 4.05 mL of