Title: Analisys of 3 chips with I(Vdda) syndrome
1Analisys of 3 chips with I(Vdda) syndrome
3 chips suffering the I(Vdda) syndrome have been
stripped from 2 AMS modules and have been
observed with the thermocamera, under microscope
and under micro x-ray. The informations gathered
are compared with the bare module probing
previously done in Milano.
G. Gariano,C. Gemme, P. Netchaeva, L. Rossi, A.
Rovani, F. Vernocchi INFN- Genova
2Module 20210210142301, chip 6 thermographic
image from Inframetrics 760
Raw 56
Colum 9,10
Hot spot localized and 5C above normal
3Module 20210210142301, chip 6 microscope images
Hard metal, not Indium, deeply connected to chip
surface. Impossible to take it off with W-needles.
Raw 56
Colum 9,10
4Module 20210210142301, chip 6 x-ray images
Nothing visible where I did operate with
W-needles
5Module 20210210142301, chip 6, scan with all
column pairs enabled
Digital inj
Analog inj (both int. and ext.)
6Module 20210220011701, chip F thermographic image
Hot spot localized and 10C above normal
Col 17
7Module 20210220011701, chip F, microscope image
Col 17
Hard metal, not Indium, deeply connected to chip
surface. Impossible to take it off with W-needles.
8Module 20210220011701, chip F x-ray image
Nothing visible in insert
9Module 20210220011701, chip F, scan with all
column pairs enabled
Digital inj
Analog inj (both int. and ext.)
10Module 20210210142301, chip 8 thermographic image
Hot spot localized and 10C above normal and hot
column bus
Raw 73
Col 9,10
11Module 20210210142301, chip 8 microscope image
Raw 73
Hard metal, not Indium, deeply connected to chip
surface. Impossible to take it off with W-needles.
Col 9,10
12Module 20210210142301, chip 8 x-ray image
Nothing visible in raw 72
13Module 20210210142301, chip 8, scan with all
column pairs enabled
Digital inj
Analog inj (both int. and ext.)
14Tentative conclusions
- In all 3 cases we observe
- a hot spot in correspondence of where the
electronics problem appears - a deposit of hard material (debris from
cutting?) in correspondence with the hot spot - the hard material has low-Z (like silicon) as it
is invisible at x-ray imaging - It would be interesting to have comments from
electronics and module experts. - We probably have be more careful in the cleaning
process debris can more easily be trapped by the
(sticky?) In bumps.