DEBATE - PowerPoint PPT Presentation

1 / 19
About This Presentation
Title:

DEBATE

Description:

... RECD value differs dramatically in paediatrics as study shown by Pasa & Revit ... Variable paediatric resonant peaks for infants (7200Hz compared to 2700Hz ... – PowerPoint PPT presentation

Number of Views:27
Avg rating:3.0/5.0
Slides: 20
Provided by: stephan109
Category:

less

Transcript and Presenter's Notes

Title: DEBATE


1
DEBATE
  • In support FOR the benefit of using Real ear
    Measurement

2
Over estimation of software
  • A study conducted by Hawkins Cook 2003 (Hearing
    aid software predictive gain values. How
    accurate?)
  • Click n fit simulation typically over predicted
    gain (by up to 10dB in the High Frequencies)
  • Only way to ensure accurate verification is by in
    situ measurement

3
Fig 1.
4
(No Transcript)
5
(No Transcript)
6
(No Transcript)
7
(No Transcript)
8
(No Transcript)
9
(No Transcript)
10
(No Transcript)
11
(No Transcript)
12
(No Transcript)
13
(No Transcript)
14
(No Transcript)
15
  • Kuk Ludvigson (2003) demonstrated that real ear
    measurement was essential to ensuring improved
    successful fitting
  • Flexibility of modern digital aids platforms
    should prove advantageous for verification of
    fitting goals

16
Average RECD ?
  • Your average RECD value differs dramatically in
    paediatrics as study shown by Pasa Revit (1992)
    Individualised correction factors in pre
    selection of hearing aids
  • Infant ear canal SPL values up to 20dB higher
    than measured gain output from 2cc (Michelle R.
    Petrak PHD Hearing Aid Fittings in infants
    small children)
  • Variable paediatric resonant peaks for infants
    (7200Hz compared to 2700Hz in adults)
  • Kreuger Reuben (1987)
  • Only true accurate measurement of the ear is in
    situ

17
Fig 2.
  • Table of average ear volumes (Alencor et al 2005)

18
Repeatability Reliability
  • Repeatable real ear measurement performance of a
    digital aid within 1-5 dB
  • (Ringdhal Lejon 1984, Hawkins 1987,1991)
  • Accuracy of free field aided thresholds variable
    by 15dB (Hawkins et al 1987, Humes Kirn 1990)
  • Measures out with normal audio frequencies (e.g.,
    a peak at 2500Hz)
  • MHAS study MRC Nottingham 2000 shown REM only
    reliable source of verification

19
Time Money
  • Experienced REM should add no more than 5 minutes
    on to a fitting appointment
  • Forth Valley Telephone review study shown 57 of
    first fits discharged without needing further
    adjustment (over 2 month study)
  • Saves time and money on review appointments
  • Good visual rehabilitation tool at the fitting
    appointment
Write a Comment
User Comments (0)
About PowerShow.com