Title: The Crane Drive F7 Crane firmware


1
The Crane Drive F7 (Crane firmware)
Made for cranes!
2
Features of F7 Crane Firmware
Dedicated functions
  • Brake sequence
  • Swift Lift function
  • End of travel limit function
  • Flexible over-load/torque detection

3
Features Brake sequence
1. Brake Sequene There are many interlock in
order to ensure the safety operation and smooth
operation.
4
Features Brake sequence
Run Command is given
Output frequency increases
5
Features Brake sequence
  • Then, our intelligent F7 crane
  • Inverter thinks if the brake is ready
  • to open
  • Output frequency is enough high?
  • Output current/torque is enough high?

6
(No Transcript)
7
Features Brake sequence
Okay! Then lets open the brake!
8
Features Brake sequence
But, output frequency doesnt increase
immediately! Lets wait to accelerate till brake
is completely opened to avoid brake friction.
9
Features Brake sequence
Is brake really open? If not, inverter gives
fault out and system should stop immediately
because something is wrong!
10
Features Brake sequence
After checking several safety conditions inverter
faintly accelerates to the speed to be set.
11
Features Brake sequence
Stop Command is given (run command is removed)
Output frequency starts to decelerate
12
Features Brake sequence
If output frequency is reached to brake close
frequency, then inverter requests to close the
brake.
13
Features Brake sequence
Output frequency is kept not to fall down till
brake is completely closed!
14
Features Brake Sequence
15
Features
2. Swift lift function When the inverter detects
light load, output frequency is increased
automatically according to settings. gt Increases
Productivity!