FCUL experiment: Lifetime of cosmic muons - PowerPoint PPT Presentation

1 / 14
About This Presentation
Title:

FCUL experiment: Lifetime of cosmic muons

Description:

Colegiul National 'Mihai Eminescu', Satu Mare. Liceul Teoretic 'Lucian Blaga', Constanta ... The second region (II) ranges between ti=0,7 s and ts=8,2 s ... – PowerPoint PPT presentation

Number of Views:22
Avg rating:3.0/5.0
Slides: 15
Provided by: Mir9
Category:

less

Transcript and Presenter's Notes

Title: FCUL experiment: Lifetime of cosmic muons


1
FCUL experimentLifetime of cosmic muons
  • Colegiul National de Informatica "Tudor Vianu",
    Bucuresti
  • Colegiul National Mihai Eminescu, Satu Mare
  • Liceul Teoretic "Lucian Blaga, Constanta

2
Introduction
3
(No Transcript)
4
(No Transcript)
5
(No Transcript)
6
(No Transcript)
7
(No Transcript)
8
Run 8
Run 10
Run 6
Run 7
Run 11
Run 14
Run 15
9
(No Transcript)
10
(No Transcript)
11
Another method of datanalysis
The data was processed using Microsoft Excel
A) Visual Analysis 1. Identification of the 3
regions of the plotted graph The first region
(I) ranges between t0,1 µs and t0,6 µs The
second region (II) ranges between ti0,7µs and
ts8,2µs The third region (III) ranges between
t8,3µs and t25,5µs
12
Graph of events in region II, approximated by an
exponential curve
Using the equation that approximates the graph in
region II, the mean muon lifetime is
tµ1/0,46412,1547 µs.
13
Graph with measured values (Ns), computed with t
obtained by us (Ncalsc-1) and computed with t
given in the bibliography (Ncalc-2)
tµ measured 1/0,48712,0529 µs tµ
computed 1/0,46412,1547 µs tµ
bibliography 1/0,45512,1973 µs
14
  • Observations 
  • A possible cause of the discrepancies between the
    theoretical curve and the experimaental one is
    the relatively small number of events recorded.
  • For some muons, after the disintegration (start)
    flash, a flash could appear, due to emission of
    photons in the capture of negative muons by
    atoms, or the capture of electrons by the
    positive muons potential energy well (formation
    of muonium). This flash could be interpreted as a
    false electron (stop) flash, thus altering the
    effective disintegration time.
  • In the statistical analysis, the values with
    which the calculations were made, were chosen
    with a dose of bias.
Write a Comment
User Comments (0)
About PowerShow.com