Title: Modeling Urban SurfaceAtmosphere
1Modeling Urban Surface-Atmosphere Sensible Heat
Exchanges
Sarah M. Roberts1, T.R. Oke1, A. Lemonsu2,
C.S.B. Grimmond3 and P. Jackson1
1Department of Geography, University of British
Columbia, Vancouver, B.C., Canada 2Centre de
Recherches Météorologiques, Météo-France,
Toulouse, France 3Atmospheric Sciences Program,
Indiana University, Bloomington, IN, USA
2- Overview
- Methods
- Field site description
- Measurement approach
- Modeling approach
- Simulation Results
- Surface Energy Balance
- Sensitivity to Wind Speed
- Sensitivity to Urban Geometry
- Sensitivity to Surface Radiative Properties
- Sensitivity to Surface Thermal Properties
3Field Site Characteristic Mediterranean City
- Marseille is an ideal locale in which to study
urban surface-atmosphere sensible heat exchanges - Warm, dry summer climate
- Massive urban development
- Very little vegetation cover
High-density buildings (H/W 2.0) with clay tile
roofs and thick stone walls (0.5 - 1 m) provide
a large thermal mass for heat storage
4Measurement Approach
Observations performed in the constant flux layer
between 35-44 m above street level. Two levels
of eddy correlation instrumentation directly
measured radiometric (Q), turbulent sensible
(QH), and latent heat (QE) fluxes. Net energy
storage flux (DQS) is calculated as the residual
in the measured surface energy balance.
L1
L2
5Modeling Approach
Massons Town Energy Balance model (TEB, 2000)
couples the micro- and meso-scales and is widely
used to represent the urban energy budget in
atmospheric circulation models.
- Forced with atmospheric and radiation data
recorded above-roof level. - Incorporates detailed representations of the
urban surface to simulate individual energy
balances for walls, roads, and roofs. - TEB performs well at highly-urbanized sites
(central Mexico City, Vancouver light industrial
area, and Marseille city center). -
6Simulated Surface Energy Balance
- TEBs good performance at this site and others
suggests that the model can be reasonably
employed to gain more insight into responses to
various surface and meteorological forcing
parameters at the Marseille site. - Thirty-minute TEB energy balance output are
converted to hourly ensemble averages over an
eight-day period in July 2001. Results are
expressed in terms of DQS biases ( DQSREF -
DQSSIM).
7Simulated Sensitivity to Wind Speed
- Flow consistently weaker/stronger than the
reference (measured) flow generates expected
behavior - Weaker daytime flow facilitates greater energy
conduction whereas higher daytime flow favors
turbulent surface-atmosphere exchanges. - At night, weaker flow results in more DQS
release. A consequence of strong daytime flow is
a reduced energy source for nocturnal release.
8Simulated Sensitivity to Urban Geometry (I)
Canyon Aspect Ratio (reference H/W 2.0)
- Canyon H/W is altered by adjusting the average
building height and keeping canyon width constant
between model runs. - These modifications do little to impact the
amount of energy taken up or released from
storage (note magnitude of biases).
9Simulated Sensitivity to Urban Geometry (II)
Building plan area (reference 56 Bldg.)
- In these simulations, the relative proportion
of impervious ground and buildings is adjusted
(plan area of water and vegetation are held
constant). - More building volumes (less canyons)
greater local-scale
energy uptake.
10Simulated Sensitivity to Surface Radiative
Properties
Built surface albedo
- Largest biases occur in the daytime and with
higher surface albedo values. - Changes to surface emissivity (not shown) do
little to impact the local-scale energy balance
at this site (biases lt 3 W m-2).
11Simulated Sensitivity to Surface Thermal
Properties
- Thinner road surfaces are more responsive later
in the day, when the oblique solar path allows
for lower canyon exposure. - Modifying wall thickness results in little
diurnal bias. - Greater roof volume, while impacting the hourly
behavior of energy uptake/release, results in
little (1 W m-2) overall diurnal bias.
12Concluding Remarks
Numerical simulations performed with a
local-scale urban surface-atmosphere model
demonstrate the relative impact of various
meteorological and surface forcing parameters at
a site in the city center of Marseille, France
- Wind speed at this highly urbanized site plays
the most significant role in surface-atmosphere
coupling and subsequent sensible heat exchange. - Sensible heat flux partitioning is impacted to a
lesser extent by changes to urban geometry, with
the most bias associated with plan area of
buildings. - Increased built surface albedo and modifications
to surface thermal parameters result in
appreciable differences in diurnal ?QS
partitioning.