Charge diffusion model (again) - PowerPoint PPT Presentation

About This Presentation
Title:

Charge diffusion model (again)

Description:

... charge to get spread between pixels ... had generated two sets of data points for deep ... Since then, did the mega-run; 1 1 1mm3 steps in x, y and z. 3900 ... – PowerPoint PPT presentation

Number of Views:14
Avg rating:3.0/5.0
Slides: 18
Provided by: paulda6
Category:
Tags: again | charge | diffusion | model | run | up

less

Transcript and Presenter's Notes

Title: Charge diffusion model (again)


1
Charge diffusion model (again)
  • Paul Dauncey

2
Diffusion model
  • Same model as described in last meeting
    (27/02/09)
  • Simple diffusion of charge to get spread between
    pixels
  • Tuned to agree with Giulios GDS results at
    centre of pixel
  • Previously, had generated two sets of data points
    for deep p-well
  • MIP-like, i.e. charge spread evenly throughout
    the epitaxial layer depth this was done on a
    fine grid of 11mm2 steps in x and y
  • 55Fe-like, i.e. Charge deposited at a single
    point in depth this was done for steps of 1mm in
    depth but coarser steps of 55mm2 steps in x and
    y
  • Since then, did the mega-run 111mm3 steps in
    x, y and z
  • 3900 separate diffusion runs
  • Use translation and reflection symmetry to give
    full 30000 points
  • Gives detailed response to 55Fe and can be
    averaged in z to give original MIP-like response

3
Depth dependence
z 0.5mm
4
Depth dependence
z 1.5mm
5
Depth dependence
z 2.5mm
6
Depth dependence
z 3.5mm
7
Depth dependence
z 4.5mm
8
Depth dependence
z 5.5mm
9
Depth dependence
z 6.5mm
10
Depth dependence
z 7.5mm
11
Depth dependence
z 8.5mm
12
Depth dependence
z 9.5mm
13
Depth dependence
z10.5mm
14
Depth dependence
z11.5mm
15
Fractional spectrum 1mm with MIP-like z
  • White are all values in 33 pixel array
  • Red are values in central pixel

Paul Dauncey
15
16
Fractional spectrum 1mm with 55Fe-like z
  • Spectrum extends much higher now due to hits just
    below diodes
  • Low peak still clearly visible value of 31
    fixed by matching Giulios results
  • Is there a high peak? If so, maybe at 95? Model
    not accurate here...

Paul Dauncey
16
17
Fractional spectrum 55Fe-like z vs Marcel
Red old pixel Green new pixel
  • Line shows guess at 10 simulation threshold
    equivalent for comparison
  • Stretch Marcels plot to only go to high peak
    position 200mV
  • Agreement in not good in detail but general shape
    is similar

Paul Dauncey
17
Write a Comment
User Comments (0)
About PowerShow.com