Title: Vacuum tests


1
Vacuum tests
  • Problem description
  • Valve presentation
  • Test setup
  • Measurements Results
  • Conclusions

2
Problem description
  • Separated primary and secondary vacuum to obtain
    good ring vacuum
  • Thin foil required because of multiple scattering
  • Intrinsically safe solution is desired

Secondary vacuum
Thin foil
Electronics, cables, etc.
Primary vacuum
3
Valve presentation
  • Valves that react to differential pressure
  • Electric/Pneumatic, but
  • Fail-safe solution required
  • Proposal Gravity controlled valve

4
Test setup
  • Leak rate during normal operation (with/without
    pump)
  • Preliminary
  • Dynamic response to sudden pressure changes
    (leaks)
  • System behavior during pump down

Removed picture of vacuum test setup
5
Test setup (2)
Sander Klous 24-11-2000
6
Measurements Results
  • Conductance (H2O)
  • 10-3 liter/sec without dedicated pump
  • 10-5 liter/sec with dedicated pump
  • Expected secondary vacuum pressure 10-4 mbar
  • This would result in
  • 10-9 mbar l/s leak-rate

Pumping slots
7
Measurements Results (2)
  • Dynamic response
  • Maximum differential pressure over the valve is 6
    mbar
  • Measurement is dominated by the bellow
    configuration (see picture)
  • More realistic measurements are required with
    faster gauges

Removed picture of tandem (gravity-controlled)
valves
8
Measurements Results(3)
Secondary vacuum
  • Pump down time
  • Conductance between primary and secondary vacuum
  • Bellows (L 1 m, d 20 mm)
  • Maximum pressures in range of the gauges 500
    mbar, calibrated with a baratron.
  • 3 hours to around 1 mbar
  • (?p 9 mbar at 500 mbar)
  • 3 hours to 10-5 mbar

Bellow
Primary vacuum
Restriction
Valve 2
Valve 1
Primary pump
Turbo pump
9
Conclusions
  • All measurements indicate the gravity controlled
    valve can work
  • For the correct dynamic pressure analysis a more
    realistic setup is required