RefleX - PowerPoint PPT Presentation

1 / 15
About This Presentation
Title:

RefleX

Description:

Directional overcurrent relays. RefleX. Accurate angle-measurement. U1. U2 ... Overcurrent and EF. Overvoltage / Undervoltage. Full scheme 4-zone impedance ... – PowerPoint PPT presentation

Number of Views:91
Avg rating:3.0/5.0
Slides: 16
Provided by: larsbach
Category:

less

Transcript and Presenter's Notes

Title: RefleX


1
RefleX
Modern protection and control
- the easy way
2
RefleXMeans and measures - the user in focus
  • Uncomplicated solutions
  • Requires flexibility
  • Modularity
  • User-specification
  • End results are
  • - Efficient operation
  • - Cost-effective operation
  • - Reduced life-time cost

3
RefleXConfusion or solution
Iogt
Igt
I
4
RefleXConfiguration and settings - one example
5
RefleXMenu and settings
EF current set Io 80/0.8A CT 100/1A In 1A
OC/EFÐ I1 124A I2 120A I3 123A
Trip records
EF voltage set Uo 10392/90V VT 12701/110V
Low current set Igt 160/4A tgt 1.5s Def.t CT
200/5A In 5A
EF angle set Direction 90 Sector 120 tø 1.5s
High current set Igtgt 1200/30A tgtgt 0.05s Def.t CT
200/5A In 5A
YMD 2002-05-29 HMS 135236 Password
Frequency 50Hz
6
RefleXUser-Interface
  • 4 - line display
  • Complete keyboard
  • Spreadsheet navigation
  • 3 signal lamps
  • 2 week calendar/clock

7
RefleXConnections (I/O)
  • 3 voltage inputs
  • 4 current inputs
  • 8 opto-inputs
  • Auxiliary supply
  • 8(7) output relays
  • Dual IEC 870 fiber bus
  • Internal fiber bus

8
RefleXLocal relay optical fiber network
2-winding diff.
RTU
Igt/Io
Zlt
  • Local duplex ring bus - IEC 870 (ring or star)
  • Remote/local control - IEC 870
  • Internal bus for multi-module relays

9
RefleXRemote application
Remote application
Fibre converter
RTU
IEC 870 variant Conversion IEC 870 standard
Modem
Modem
IEC 870 Local Relay Network
10
RefleXMulti-modular protection
3-winding differential protection
HV
MV
LV
  • Internal bus
  • Current measurement

11
RefleXLarge dynamic range in current measurement
  • IEC inverse curves
  • Basic setting 0.5-2,5In
  • Measuring range 30basic setting
  • Max current 52.530 375A
  • Correct measurement at 2.5A
  • Two parallel measurements
  • 1/16 relationship in attenuation
  • High resolution in measuring range
  • High accuracy in measuring range

I max 375A
14 bit in the whole range
14 bit in1/16 of the measuring range
In 5A
12
RefleXAccurate angle-measurement
  • Differential measurement
  • Large deviation at small errors
  • Need for synchronous measurement
  • Multiplexing not accepted
  • Important at -
  • Impedance relays
  • Earth-fault directional relays
  • Directional overcurrent relays

Ures U1-U2
U1
U2
13
RefleXMeasuring system
14
RefleXSome examples of relay versions
  • OC, DEF, Neg.sequence, 1..6 shot AR
  • Overcurrent and EF
  • Overvoltage / Undervoltage
  • Full scheme 4-zone impedance
  • 2- or 3-winding transformer differential
  • Distance-to-fault locator

15
RefleXTechnical data
  • 3 voltage inputs, 0-170V AC
  • 4 current inputs, In 1A / 5A AC
  • 8 opto inputs, 24-240V bipolar DC
  • 7 output relays (2 with NO/NC contacts)
  • 1 watchdog with NC contact
  • Auxiliary voltage 24-240V AC/DC