RadTherm Analysis EcoZ Stud versus Steel Stud Summer - PowerPoint PPT Presentation

1 / 7
About This Presentation
Title:

RadTherm Analysis EcoZ Stud versus Steel Stud Summer

Description:

Polystyrene Foam Board (1.5 inch) Gypsum Board (0.5 inch) 130 W/m2. Results. Eco-Z Stud ... The heat conducts along the stud and through to the interior wall of ... – PowerPoint PPT presentation

Number of Views:34
Avg rating:3.0/5.0
Slides: 8
Provided by: craigm77
Category:

less

Transcript and Presenter's Notes

Title: RadTherm Analysis EcoZ Stud versus Steel Stud Summer


1
RadTherm AnalysisEco-Z StudversusSteel
Stud(Summer)
  •                  

2
RadTherm Model Setup
130 W/m2
Wall Top View
(Solar Load for a 90F day full sun on wall)
Concrete
Polystyrene Foam Board (1.5 inch)
Stud 25 gauge Steel Versus 0.09inch EcoZ (16
inches on center)
Gypsum Board (0.5 inch)
3
RadTherm Model Setup
Polystyrene Foam Board (1.5 inch)
Concrete (10 inch)
130 W/m2
Gypsum Board (0.5 inch)
Wall Side View
4
Results
Interior Surface Temperatures of Gypsum
Eco-Z Stud
Steel Stud
5
Results
Interior Surface Temperatures of Foam and Stud
Eco-Z Stud
Steel Stud
6
Results
Exterior Concrete Surface Temperatures
Eco-Z Stud
Steel Stud
7
Conclusion
  • Steel studs pull heat away from the exterior
    concrete wall. The heat conducts along the stud
    and through to the interior wall of the building.
  • Eco-Z studs are considerably less conductive and
    minimize the heat that is transferred from the
    exterior environment into the building. This
    results in less energy requirements to maintain a
    comfortable air temperature within the building.