Title: Prevention of Sewer Spills
1Prevention of Sewer Spills using Remote
Electronic Monitoring
July 23, 2008
Gregory M. Quist, Ph.D
2SOUND FAMILIAR?
April 3, 2007 Major sewage spill fouls lagoon
January 16, 2006 Big Sewage Spill Closes
California Beaches
March 28, 2006 Raw sewage flows into reservoir
3OR HOW ABOUT THIS ?
Aug 28 809 PM US/Eastern Dead Dog Blamed for
Sewage Backup in Utah
February 27, 2006
Prank Causes Concord Sewage Spill
November 28, 2001
Folsom sewer backup act of vandalism, city says
4The BIG Picture
- Increasing public expectations (plus lawsuits)
- Evolving regulations
- e.g. CA 2006 WDR, Sewer Overflow CRTK Act
- Increasing stress on CA water supplies
- - Todays sewage is tomorrows potable water
- - You must protect your source water
- Rising operating costs
- Gas prices, vehicle operations, HC costs
5The Old Way of Doing Things
6The Old Way of Doing Things 2
7Spill Avoidance - 20th Century
NO SPILLS ?
Capital Improvement Projects
Long Term Repair
Short Term Repair
Aggressive Cleaning Program
Frequent Inspection
Manual Monitoring of Hot Spots
8NO Spills Still Occur
- Why?
- Aging collection system
- FROG
- Accumulated sediment
- Construction debris
- Mechanical Failure
- Communications failure
- Vandalism
Spill picture 2
9Real-Time Know about it nowContinuous Measure
all the time Remote Do it from a distance
Sewer Monitoring
- Spills dont always happen where you expect them
- How can you prevent them from happening?
- Widespread continuous monitoring of your
collection system
10Continuous Real-Time Monitoring ?
11Continuous Real-Time Monitoring ?
12Continuous Real-Time Monitoring ?
13Continuous Real-Time Monitoring ?
14Sewer Monitoring Evolution
15Convergence
February 2005
Hadronex formed to provide SSO solution
Technical solution developed from scratch -
No good solution available on the market
Solution developed from industry interviews -
Vallecitos WD (San Marcos) - Fallbrook PUD -
Valley Center WD with the intent to be a
dedicated spill prevention system...
- Founders
- David A. Drake Water San Diego CWA, Rincon
del Diablo MWD - Technical CalTech (EE), JPL, DEC,
SAIC - Gregory M. Quist Water San Diego CWA, Rincon
del Diablo MWD - Technical Yale / UCSB
(physics), McDAC, SAIC
16Attributes of Effective CollectionMonitoring
System
- In order to be most effective, remote monitoring
needs to be performed at a substantial number of
locations - An effective real-time monitoring system needs
to have the following attributes - Low cost - to be economically feasible at large
of sites
- High reliability - so a surcharge or potential
spill isnt missed
- Low maintenance - to keep field visits to a
minimum
- Stays out of the water - avoid making problems
- Can be re-located - move to better locations if
necessary
- Easy to install - minimize time in traffic
- No confined space entry - avoid safety problems
- Data logging - for trends and predictive
maintenance
17Sewer Monitoring Technologies
Flow Monitors (e.g. Flo-Dar)
Float Alarms (e.g. M-80)
Level Monitoring (e.g. SmartCover)
Semi-revolutionary revelation For sewer overflow
prevention, LEVEL is key (not flow)
18How the SmartCover System Works
Traffic-rated antenna
Waterproof enclosure Battery powered
Ultrasonic sensor
19SmartCover Wireless Network Architecture
Digital network ground station
Digital network server
Local digital radio base station
Communications satellite
INTERNET
Customer Interfaces
INTERNET
SmartCover Site
- Fully two-way using existing digital network
- Enables drop-in rapid installation
- Low bandwidth and highly reliable
- Only wireless system to survive Katrina
Hadronex server
20Elimination of Sewer Overflows using a Continuous
Real-Time Monitoring System
Rick Carver, City of Hawthorne Gregory Quist,
Ph.D. David Drake, Hadronex
CWEA 2008 Session 40 - Collection
Systems Wednesday, April 16, 2008
21Hawthorne Collections System
68 Hot Spots in Collection System
22Layout of Hawthorne Monitoring System
Picture of locations in Hawthorne collections
system
50 SmartCovers in Collection System
23116th StreetNovember 15, 2006
24(No Transcript)
25(No Transcript)
26Cerise StreetDecember 26, 2006
27Water Level Below Sensor (in)
Shelf Level 11
Alarm Level 10
Date
28Cerise Surcharge Event History
Water Level, Inches Below Sensor
Date/Time
29Carlsbad, CA
November 26, 2007
Chinquapin Street
Surcharge Cause Root ball downstream
SPILL PREVENTED
30Oxnard, CA
December 11, 2007
Rice Avenue and Hwy 101
Surcharge Cause Accumulated grease in
slumped pipe downstream
SPILL PREVENTED
31El Segundo, CA
February 19, 2007
Lift Station 2
Surcharge Cause (a) Pump turning, but
failed to prime (b) SCADA indicated no
problem (c) Water level rose to alarm level
SPILL PREVENTED
32San Diego County, CA
November 14, 2006
Surcharge Cause - Failed pump at pump
station - No SCADA notification -
Water backed upstream
SPILL PREVENTED
33Raw level data
Rolling daily average
SmartCover
I and I measurement
CIMIS Station daily rainfall
Pre-rain baseline
Alarm Level
Inches from Sensor
Daily rainfall (in)
34Where to Locate Sewer Monitors
- Where youve had a spill before
- - Upsteam, downstream, at location
- Hot Spots
- - Places you typically already monitor or need to
clean - often, lift stations (backup or primary)
- Environmentally sensitive spots
- - Rivers, ocean, wetlands, canyons, bays,
sloughs, etc.
- Politically sensitive spots
- - Schools, hospitals, public venues, commercial
areas, - district boundaries
- Where you want to know whats going on
- - I and I, dumping, easements, difficult areas,
etc.
35Smartcover?Agency Scorecard
As of July 21, 2008...
SPILLS PREVENTED 161 ILLEGAL INTRUSIONS
CAUGHT 16 HOURS OF OPERATION gt
1,700,000 SURCHARGE FALSE ALARMS
0 SPILLS MISSED 0
36Conclusions
- The world is changing
- - Higher customer expectations
- - More litigation
- - Higher fines
- - CA State WDR 2006
- HAWTHORNE Pre-SmartCovers 10 spills per year
- Post-SmartCovers 0 spills per year
- The old way of doing things is not good enough
anymore -
- Technology - like the SmartCover - is now
available and affordable - that revolutionizes how we can monitor our
collection systems - With 7/24 real-time remote monitoring and
maintaining aggressive - cleaning and inspection programs,
SPILLS CAN BE ELIMINATED
37THANK YOU !