Title: Dimension Lynx Presentation


1
Chemistry Evolution Dade Behring Dimension Lynx
Syst David Tshiporo .
.
.
2
The Dimension Lynx System
3
(No Transcript)
4
Laboratory Process Overview
Pre-Analytical
Post-Analytical
test order
sample collection
storage retrieval
transport to lab
result release
process sample
result interpretation
sample analysis
Analytical
5
Pre-Analytical Challenges
  • Sample Collection
  • Tube type
  • "Plasma for this...serum for that"
  • Multiple tubes drawn based on instrument
    configurations
  • Chemistry analyzer - BMP's
  • Immunoassay analyzer - Troponin
  • Specialty analyzer - HbA1C
  • Time, Labor Supplies
  • Additional time taken to draw 2 tubes vs. 1 tube
  • Additional supplies used
  • Impact on sample tube delivery
  • Transport to Lab
  • "Collect to Receive"

6
Pre-Analytical Challenges
  • Process Sample
  • Receive
  • Manual process based on number of tubes
  • Sort
  • Department, Tube Type, Stat vs. Routine
  • Centrifuge
  • Decap
  • Repetitive manual process
  • Aliquot/Send-outs
  • Daughter tube
  • Label
  • Pour Off
  • Transport
  • Delivery to various workstations

7
Analytical Challenges
  • Sample Analysis
  • Determine which analyzer sample should be run on
  • What tests are configured on what analyzer
  • Is the analyzer calibrated
  • Has QC been performed
  • Is the analyzer already running tests
  • Which analyzer will provide best TAT
  • What happens if one analyzer is off-line
  • Do I have enough sample
  • Does the sample have a clot

8
Post-Analytical Challenges
  • Result Interpretation
  • Do I need to re-run the sample?
  • Outside panic range
  • Outside linear range
  • Does the result require reflex testing?
  • What is the impact of HIL on the result?
  • Results Release
  • Manually releasing test results to LIS
  • Storage Retrieval
  • Where do we store the sample what in which
    order
  • Finding the darn sample for reuse

9
Laboratory Process Overview
Pre-Analytical
Post-Analytical
test order
sample collection
storage retrieval
transport to lab
result release
process sample
result interpretation
sample analysis
Analytical
10
Dimension Lynx System
11
INTEGRATED
AUTOMATED
FLEXIBLE
12
Sample Management Module
  • Centralized operation for the whole system
  • "Links" two Dimension RxL Max instruments
    together
  • "Links" one Dimension RxL Max instrument and one
    DPC Immulite instrument together
  • View each Dimension from one common monitor
  • The beauty of the Dimension Lynx...One Operator!

13
Sample Loading Delivery
  • Sample Rack
  • Standard Rack 48 tube capacity
  • Priority Rack 12 tube capacity
  • Sample Rack Lanes
  • 12 standard rack input/output lanes
  • 2 priority rack input lanes
  • 2 priority rack output lanes
  • 600 Sample Tube load capacity
  • Simultaneous processing of a wide variety of tube
    types and sizes
  • Sample Throughput 300 tubes/hr

14
Sample Decapping
  • Works w/stopper and screw-cap tubes
  • Able to use a range of tube sizes from various
    manufacturers
  • Reduced contact with potential bio-hazards
  • Compact, dependable design
  • Reduces manual repetitive processes

15
Sample Transfer Module
  • True clot detection
  • Outstanding sample level sensing
  • Delivers sample aliquot from primary tube to
    aliquot segment
  • Aliquot segment
  • Contain 63 wells/segment
  • Holds 12 segments
  • 756 sample capacity
  • Quick release of primarytube to the Sample
    Management Module for further needs

16
an excellent example of purposeful
innovation and intelligent evolution
  • First to introduce Chemistry/Immuno testing on a
    single integrated platform!
  • Excellent footprint for a high volume analyzer
  • Simple, one-touch operation
  • 1 selling analyzer for the past six years in a
    row

in the US market - 2005 Information Dynamics
Market Monitor Report
17
QuikLYTE IMT System
  • Fast and Easy
  • Integrated sensor for Na, K, Cl-
  • Sample result in 36 seconds
  • True Automatic calibration
  • No external calibration required by the
    operator!!!
  • Stability and Reliability
  • Indirect Potentiometry
  • Small sample volume - 40 µL
  • Ready to use No maintenance
  • Stability 5 days

18
Immunoassay Module
  • Advanced Technology
  • CrO2 (no magnetic resonation)
  • Enzymatic cascade highly sensitive, fast
  • 1 or 2 step heterogeneous sandwich assays
  • High throughput 336 tests/hour
  • Time to first result 16 - 18 minutes
  • Concurrent Analysis

Dual Dimension RxL Max Suite configuration
19
Reagent Management System
  • Practical
  • Automatic loading of up to 36 Flex cartridges
    simultaneously
  • Automatic disposal of used Flex
  • Ideal for nightshifts and weekend duties
  • Consolidation
  • ca. 180 methods onboard concurrently
  • Reduce sample splitting and handling
  • Productivity
  • Automatic reagent hydration
  • Dedicated hydration station optimize
    processing efficiency

Enhanced Productivity
RMS Module
"No Reagent Prep Required By The Operator"
Dual Dimension RxL Max configuration
20
The Flex Concept
"No Reagent Prep Required By The Operator"
Dual Dimension RxL Max configuration
21
Lynx Option 1 Methods( gt 100 )
1 Open Channel application 2 Automated 3 Under
Development
22
Lynx Option 2 Methods( gt 190 )
1 Open Channel application
23
Chemistry Samples Matrix
24
Alert Screens
25
Alert Functions
26
STAT Alert
27
Sample Alert
  • Focus on abnormal samples
  • Auto-dilute
  • Panic
  • Reflex testing
  • Sample being rerun for process error
  • 1 button access to test results

28
Supplies Alert
  • Early warning for low Flex reagent
  • User programmable trigger values
  • Complements Systems Needs function

29
QC Alert
  • Individual test result flagging for out-of-range
    QC test
  • Active Alert until mitigated or corrected
  • Easy EDIT/Rerun

30
Calibration Alert
  • Early warning for expiring calibration
  • User selectable intervals for alert
  • Only flags on-board lots
  • 1 button access to calibration set-up screens

31
Sample Quality Management
  • HIL Hemolysis, Icterus, Lipemia
  • No reagents used water only
  • 1 cuvette
  • 20 uL of sample
  • Customer Definable
  • Intelligent sample-specific ordering
  • Individual test result flagging
  • 4 modes of operation
  • OFF
  • ON
  • Auto ON
  • Manual request

32
HIL Configuration
Intelligent sample-specific ordering Individual
test result flagging
  • Customer-defined indices alert values
  • 4 modes of operation
  • OFF
  • ON
  • Manual
  • Auto-ON
  • Results sent to LIS
  • No impact to STAT TAT

33
Automated Serum Indices
  • Can be customized for selective tests
  • Index levels 1 to 6
  • Index 1 No interference
  • Measurement filters
  • H 405/700 nm
  • I 452/700 nm
  • L 700 nm
  • No reagent
  • Single cuvette 3 tests
  • Results gt Indices are flagged
  • Includes open channel tests

34
Post Analytical Capabilities
  • Quick release of the primary tube
  • Output sort for additional testing
  • By method
  • By instrument type
  • User definable racks and lanes
  • Sample mapping for easy storage and retrieval

35
The Dimension Lynx System
  • Increase in throughput by combining integrated
    platforms
  • Reduction in labor requirements
  • Rapid, consistent turn-around-times
  • Higher degree of quality reduced errors
  • Improvement in lab safety
  • Compact footprint efficient utilization of space
  • Scaleable open architecture for future needs

36