First results of Atlas RPC cosmic rays test - PowerPoint PPT Presentation

About This Presentation
Title:

First results of Atlas RPC cosmic rays test

Description:

We define Physical Cluster as the set of contiguous strips containing the expected one. ... h strips are a little noisier than j strips (under investigation) ... – PowerPoint PPT presentation

Number of Views:28
Avg rating:3.0/5.0
Slides: 22
Provided by: www1N2
Category:

less

Transcript and Presenter's Notes

Title: First results of Atlas RPC cosmic rays test


1
First results of Atlas RPC cosmic rays test
  • Massimo Della Pietra
  • Atlas RPC Group Napoli
  • (M. Alviggi, V. Canale, M. Caprio, G. Carlino, F.
    Conventi, R. de Asmundis, M.D.P., D. della Volpe,
    P. Iengo, S.Patricelli, L.Romano, G. Sekhniaidze)

2
Outline
  • RPC cosmic rays test in Naples.
  • Definitions.
  • Test results.
  • Gap currents and single rates
  • Full Plateau curves
  • Cluster size
  • Conclusions.

3
RPC Test in Naples
  • First chamber under test in Naples BOS-B-004.
  • 32 j strips or 32 h strips were tested with
    cosmic rays using final receivers.
  • A complete scan of RPC performances with respect
    to HV and threshold values has been done.

4
DAQ Setup
TDC
Splitter board
TDC
Latch
VME
Shaper (50 ns)
Latch
Splitter board
Scaler
Shaper (50 ns)
5
Gap currents
6
Single rates
7
Single rates
8
Definitions (I)
  • 10000 muons have been triggered for each run
    with fixed HV and threshold.
  • To evaluate the RPC performances golden tracks
    were selected (1 single hit for each layer in
    drift chambers) reducing the sample to about 5000
    events.

9
Definitions (II)
Expected area
  • The RPC is considered to be efficient if there is
    an hit in the expected area (defined as the
    expected strip ? 5 mm).

m
Expected strip
10
Definitions (III)
Physical cluster
  • We define Physical Cluster as the set of
    contiguous strips containing the expected one.

m
Non physical cluster
11
j strips Efficiency vs. HV
  • Plateau efficiency 96
  • TDC e LATCH results are identical within 0,1
  • HV normalized
  • _at_ 1013 mbar, 20.5ºC

12
j strips Efficiency vs. Threshold
  • Plateau efficiency 96
  • TDC e LATCH results are identical within 0,1
  • HV normalized
  • _at_ 1013 mbar, 20.5ºC

13
j strips N. of Clusters
  • Mean N. of Clusters ? 1.01 _at_ (0.71mV,10500 V)
  • HV normalized
  • _at_ 1013 mbar, 20.5ºC

14
j strips Cluster size
  • Phys. cluster size ? 1.3 _at_ (0.71mV,10500 V)
  • HV normalized
  • _at_ 1013 mbar, 20.5ºC

15
h strips Efficiency vs. HV
  • Plateau efficiency 96
  • TDC e LATCH results are identical within 0,1
  • HV not normalized! (DCS problem.)

16
h strips Efficiency vs. Threshold
  • Plateau efficiency 96
  • TDC e LATCH results are identical within 0,1
  • HV not normalized! (DCS problem.)

17
h strips N. of Clusters
  • Mean N. of Clusters ? 1.05 _at_ (0.59mV,10500 V)
  • HV not normalized! (DCS problem)

18
h strips Cluster size
  • Phys. cluster size ? 1.4 _at_ (0.59 mV,10500 V)
  • HV not normalized! (DCS problem)

19
h and j Efficiency
  • Both curves reach 96 of efficiency
  • HV not normalized to compare the two curves !

20
h and j Cluster size
  • h strips are a little noisier than j strips
    (under investigation).
  • HV not normalized to compare the two curves !

21
Conclusions
  • The results show a good RPC behavior for both j
    and h plane
  • Efficiency ? 96
  • Cluster size 1.3 - 1.4
  • TDC and LATCH give identical results with shaped
    signals.
  • The analysis tools to fully test up to 8 RPCs
    together are ready.
  • Were ready for massive tests.

_at_ working point.