Title: The AlwaysOn Roof Monitoring and Leak Detection Systems
1The Always-On Roof Monitoring and Leak
Detection Systems
from
2- North American Partner of
- German-based manufacturer
- Primary patent holder and developer of leak
monitoring and detection products
3SMARTEX ROOF MONITORING AND LEAK LOCATION SYSTEMS
- Green roofs
- Plaza Decks
- Solar roofs
- Sloped or Flat roofs
- Waterproofing
4- Material compatibility with the SMARTEX system
- Progeo checks all roofing and waterproofing
membranes proposed to be used over the SMARTEX
system so that there are no conductivity issues.
To date, certain PVC and EPDM membranes cannot be
used, as they produce false positive signals for
leakage. Check with us to get the latest
information on these compatibilities.
5OBVIOUS STRUCTURAL DAMAGE FROM LEAKS
6NOT-SO-OBVIOUS STRUCTURAL DAMAGE FROM LEAKS
7POTENTIAL STRUCTURAL DAMAGE FROM LEAKS
8ELECTRICAL MEANS OF LEAK DETECTION AND LOCATION
MANUAL TESTING METHODS
ELECTRIC FIELD VECTOR MAPPING
SPARK TESTING
9ELECTRICAL MEANS OF LEAK DETECTION AND LOCATION
10COMPONENTS OF SMARTEX LEAK MONITORING
AND LOCATION SYSTEM
11COMPONENT 1
TYPICAL SENSOR AND CABLE FOR COLD APPLICATIONS
(ELASTOMERIC ROOFING). ALL SENSOR AND CABLE
ASSEMBLIES ARE PREFABRICATED FOR EACH
INDIVIDUAL PROJECT
12COMPONENT 1A TYPICAL SENSOR CABLE FOR HOT
APPLICATIONS (BOTH MOPPED AND ROLLED BITUMINOUS
MEMBRANES)
13COMPONENT 2 CONDUCTIVE FELT IS APPLIED OVER
THE SENSOR GRID
14COMPONENT 3 INJECTOR ELECTRODE PLACED ON TOP
OF THE MEMBRANE SYSTEM TO GENERATE THE TEST
SIGNAL OVER THE SURFACE OF THE MEMBRANE.
15TYPICAL SMARTEX SENSOR LAYOUT PLAN VIEW
16SENSOR GRID LAYOUT ON BUILDING PLAN
17TYPICAL CONSTRUCTION SMARTEX DIRECTLY UNDER THE
MEMBRANE
18TYPICAL CONSTRUCTION SMARTEX AT PARAPET
19 20LOCATE AND SECURE ALL SENSORS IN GRID ACCORDING
TO PLAN
21TAPE OR FASTEN SENSORS TO DECK, INSULATION OR
OTHER NON-CONDUCTIVE SUBSTRATE
22SMARTEX CAN BE APPLIED TO SLOPING DECKS
23OVERLAY SENSORS WITH CONDUCTIVE FELT
24USE NON-CONDUCTIVE FASTENER ASSEMBLIES WHEN IN
CONTACT WITH THE SMARTEX SYSTEM
25INSULATED FASTENERS SECURE ROOFING TO DECK
THROUGH CONDUCTIVE FELT
26ALL ROOF PENETRATIONS MUST BE INSULATED OR
NON-CONDUCTIVE
27INSTALL ROOFING OVER SMARTEX ASSEMBLY (ELASTOMERIC
ROOFING)
28MODIFIED BITUMINOUS ROOFING
29SMARTEX APPLIED UNDER 2 PLY MODIFIED BITUMEN
SYSTEM
30HAND TEST FOR CONDITION OF SENSORS
THE HAND TEST IDENTIFIES ANY DAMAGE TO THE CABLE
OR SENSOR AND LOCATES THE DAMAGE. THE CABLE IS
REPAIRED USING STANDARD ELECTRICAL
REPAIR TECHNIQUES.
31SPLICE GRID CABLES
32REPAIRED CABLE WILL GO BACK INTO SERVICE
33INJECTOR ELECTRODE AND PENETRATION THROUGH
MEMBRANE
34SENSOR AND INJECTOR CABLES CHASED FROM ROOF INTO
BUILDING INTERIOR
35SMARTEX HUB AND EVALUATION CENTER
36COMPUTER SCREEN OUTPUT OF ACTUAL LEAK OCCURANCE.
RED DOT IS THE LOCATION OF THE LEAK.
37COMPUTER SCREEN OF ACTUAL LEAK OCCURANCE USING
COORDINATE METHOD. NOTE TIME OF OCCURANCE IS
RECORDED.
38ACTUAL LOCATION OF LEAK ON THE DIOCESAN MUSEUM IN
COLOGNE, GERMANY
39DIOCESAN MUSEUM, COLOGNE, GERMANY
40LOCATING LEAKS WITHOUT SMARTEX
41ACTUAL OCCURANCE OF A LEAK ON A COMPLICATED ROOF
OVER A HOSPITAL
42HOSPITAL ROOF MULTIPLE LEAKS DETECTED SINCE
INSTALLATION IN 1999.
43SMARTEX CANNOT PREVENT THIS ABUSE BUT IT CAN
DETECT THE DAMAGE THAT OCCURS
44LOCATING A LEAK IN A ROOF COVERED BY SOIL OR
PLAZA MATERIALS WITHOUT SMARTEX
45TOO EXPENSIVE TO LOCATE AND REPAIR THE LEAKS
NOWWED HAVE TO TEAR UP THE WHOLE THING.
46Case Study BMW WORLD MUSEUM AND CENTER MUNICH,
GERMANY
47SMARTEX SENSOR GRID LAYOUT BMW WORLD
48BMW WORLD ROOF HALF FINISHED NOTE ALL MATERIALS
AND EQUIPMENT STILL ON THE FINISHED PART
49 50SKYLIGHTS WITH MULTIPLE ANGLES AND GRADES
51MULTIPLE PENETRATIONS
52SOLAR PANELS
53COORDINATION
54RECIPES FOR DISASTER!
55MATERIAL AND EQUIPMENT STORAGE ON UNPROTECTED
MEMBRANE
56(MANY) OTHER TRADES WORKING OVER UNPROTECTED
MEMBRANE
57THE FINAL CHALLENGE
ACCESSIBILITY (Once the membrane is covered, how
does one locate problems?)
58PANELS IN SLOPING CONE AREA
59SOLAR PANELS OVER MOST OF ROOF
60MEASURES TAKEN TO ASSURE A QUALITY INSTALLATION
- Full Time Inspection of Installation
- Vacuum Check all Seams
- Multiple Sweep and Inspect
61RESULT OF ONE SMARTEX SCAN (150 LEAKS LATER)
628 More Leaks.
63WHAT THE BMW WORLD PROJECT TEACHES US
- Even with Top Quality installation and
inspection, subsequent construction phase damage
resulting in leakage can occur. - Locating leaks would have been the real challenge
without SMARTEX. - Ensuring that future leaks from maintenance of
all the structures on the roof (and other causes
of membrane damage) are immediately identified
and located IS the SMARTEX promise.
We Provide Confidence!