Title: Static Proof Test @ HYTEC Bottom Tray -002
1Static Proof Test _at_ HYTECBottom Tray -002
2Pre-Test of Vertical Fixture
- Performed vertical fixture load test/calibration
checks prior to 1st test of bottom tray - Verify fixture design accuracy of load
application
3Test Article Bottom Tray -002
Thermal/Mechanical Sidewalls
Tower Simulator
Tray 2 (from prototype tower)
Bottom Tray (-002)
4Instrumentation
Load Cell (7500 lb Max)
LVDT Displacement Probes (12 Channels)
Strain Gages (20 Channels)
5Vertical Axis Static Proof Test
- Test Load 12,760 N (40 gs)
- Test performed to 100 of 3? Static Equivalent
Random Vibration Loads in tension - Compression not performed due to time constraint
- Max Predicted Flexure Loads
- Corner Flexure
- Axial 2422N
- Shear 93N
- Side Flexure
- Axial 829N
- Shear 26N
- Results NO Evidence of Damage Test Successful
6Vertical Measured Compliance
7Lateral Y Static Proof Test
- Test Load 8600 N (27 gs)
- Test performed to 100 of 3? Static Equivalent
Random Vibration Loads - Both directions were tested (positive negative)
- Y-axis loads are more sever than X-axis
- Max Predicted Flexure Loads
- Corner Flexure
- Axial 3898N
- Shear 850N
- Side Flexure
- Axial 1716N
- Shear 3104N
- Results NO Evidence of Damage Test Successful
8Lateral Y Measured Compliance
9Lateral XY (45? Axis) Static Proof Test
- Test Load 9550 N (27 gs)
- Test performed to 100 of 3? Static Equivalent
Random Vibration Loads - Both directions were tested (positive negative)
- Corner Flexure buckling critical load case
- Max Predicted Flexure Loads
- Corner Flexure
- Axial 6224N
- Shear 1473N
- Side Flexure
- Axial 1347N
- Shear 2440N
- Results NO Evidence of Damage Test Successful
10Lateral XY Measured Compliance
11Lateral XY Peak Sidewall Strains