Configuration of PrimEx data II - PowerPoint PPT Presentation

About This Presentation
Title:

Configuration of PrimEx data II

Description:

Combine the data from different detectors and reconstruct ... TACT. Primitive. Reconstructed: TAGM. nrow in TAGEHIT bank. Index of hit in TAGTHIT bank ... – PowerPoint PPT presentation

Number of Views:12
Avg rating:3.0/5.0
Slides: 12
Provided by: liyang
Category:

less

Transcript and Presenter's Notes

Title: Configuration of PrimEx data II


1
Configuration of PrimEx data II
  • Liyang JIANG
  • CIAE/UNCW

2
Event banks and Non-event banks
3
Types of Event-banks
4
Primitive Banks
  • HARDWARE
  • Data from detectors
  • TRIGGER TRIGGER_PHASE
  • Trigger latch word, and live time of trigger
    supervisor
  • Data in TRIGGER, and run number, phase
  • EVENTID
  • Run number, Event number, Timestamp, etc.

5
HARDWARE and its daughters
Raw Data
Pre-Analyzed
Reconstructed
Primitive
TAGTRHIT
H A R D W A R E
TAGTR
TAGT_LR
TAGT_LR_HIT
TAGTL
TAGTLHIT
TAGT
TAGTHIT
TAGM
TAGE
TAGEHIT
PST
TRIGPHOTON
PSHIT
PSA
TACT
TACA
TACHIT
HYCALCLUSTER
HYCAL
HYCALHIT
HYCALASSOC
HTRIGT
HTRIGA
VETOA
VETOHIT
VETOT
TRIGT
TRIGTHIT
6
Reconstructed TAGM
Variable Comment Value
energy Energy of the photon (GeV) E in TAGEHIT bank
t T-counter time (ns) t in TAGTHIT bank
e_t E-counter time (ns) t in TAGEHIT bank
status Not used
tid T channel id id in TAGTHIT bank
eid E channel id id in TAGEHIT bank
Ehit Index of hit in TAGEHIT bank nrow in TAGTHIT bank
Thit Index of hit in TAGTHIT bank nrow in TAGEHIT bank
7
Reconstructed TRIGPHOTON
Variable Comment Value
energy Energy of the photon (GeV) energy in TAGM with t100ns
t T-counter time (ns) t in TAGM 100ns
tid T channel id tid in TAGM of selected event
eid E channel id eid in TAGM of selected event
id Trigger bit id in TRIGTHIT
tdiff Time difference between T-counter time and trigger time t(TAGM) t(TRIGTHIT)
8
Reconstructed HYCALCLUSTER
Variable Comment Value
E Clusters energy (GeV) Sum of cluster cells energies
time Clusters time (ns)
x x position reconstructed with wiEi
y y position reconstructed with wiEi
z Distance target to hycal
x1 x position reconstructed with wialn(Ei/Et)
y1 y position reconstructed with wialn(Ei/Et)

9
Reconstructed PFLUX
  • PFLUX is reconstructed from TRIGGER RIGHTTIME
    banks. It stores the status of the events.
    0good, 1bad.

10
Non-event banks
  • SCALER bank and EPICS bank store the data of slow
    controls, which have not been acquired event by
    event, i.e. BPM, Beam position, Beam current,
    Temperature, etc.

11
Summary
  • This is a document to interpret the configuration
    of data in PrimEx.
  • The document will be sent to everyone soon.
  • Comments and feedbacks are welcome.
Write a Comment
User Comments (0)
About PowerShow.com