Muon Endcap AlignmentAnalog Sensor Calibrations
Software Update
  • Samir Guragain, Marcus Hohlmann
  • Florida Tech
  • October 2005

USCMS EMU meeting Fermilab, Oct 21/22, 2005
2
ME Alignment System
Transfer plate
Z-sensors
Clinometers
Note only small sample of analog sensors shown
R-sensors
DCOPS
To be featured in Physics TDR Vol.1
3
Overview
  • Update on analog sensors
  • Final calibration results for two types of
    Z-sensors
  • Final calibration results for Clinometers
  • ME1 proximity (PX) sensors
  • Software preparation
  • Overall data flow
  • To do list
  • Plans for Magnet test

4
Recent activities
  • Built specialized calibration mounts for ME1 Z-,
    R-, proximity-sensors, ME4 R-sensors
  • Calibrated all clinometers, Z-sensors and shipped
    to PSL/FNAL for mounting
  • Initiated alignment software development
    activities during 1-month summer stay at LPC
  • Graduated a CMS M.S. student
  • (Marion Ripert, now working with Laszlo Gutay
    at Purdue)

5
Progress update
Note Each sensor is sub- jected to 5 calibration runs Total in System Calibrations completed To do
R-sensors 84 60 24 (ME1,4)
Z-sens., potentiometers Z-sensors, lasers 72 12 72 12
Clinometers 48 48 (6 spare)
ME1 Proximity sensors 72 0 72
6
Full set of Z-potentiometers Sensor-to-sensor
variation
Slopes lt 1 variation
Abs (
)
Note In the end, we will actually use fit
results for response relative to a reference
voltage V(z)sensor/Vref
7
Full set of Z-potentiometers Relative errors
on slopes
Error on slopes
8
ME1 Z-Laser sensors
Z-laser sensor (ME1)
Linear Mover (barrel)
IR laser beam
Z-potentiometer (link to ME2)
Diffusely reflective surface
9
Typical Z-laser response (ME1)
Trial1 ME1-TP3-ZLB11
Slope 1.0062 (V/cm) Error in slope 0.00039
(V/cm)
Distance cm
10
Full set of Z-lasers Sensor-to-sensor variation
Slopes 1 variation
11
Full set of Z-lasers Relative errors on slopes
Error on slopes
12
Typ. Clinometer response
Angle deg
13
Full set of Clinometers Sensor-to-sensor
variation
in X
in Y
Slopes 6 variation
Note Pos. and neg. inclinations are fitted
separately each device has two
entries in each histogram.
14
Full set of Clinometers Relative Errors on
Slopes
in X
in Y
Errors on Slopes 0.3
15
Total Calibration Uncertainties
Final numbers for all sensor types

(specifications) R-sensors 100 µm (lt
430 µm) Z-sensors 55 µm (lt
1000 µm) PX-sensors 55 µm Clinometers
0.02o
16
ME1 proximity sensors
Ready to perform calibrations
2 prox. sensors
Linear mover
Establish absolute reference distance
Prec. dowel pins
Precision reference bar
Calibrate 2 sensors simultaneously
17
Road to Completion
  • Calibrate deliver in this order
  • ME1 PX sensors
  • ME1 R sensor
  • ME-1 PX sensors
  • ME-1 R sensors
  • ME4 R sensors
  • Spare clinometers
  • Document calibration project in CMS note

18
Alignment Software
  • July 05 While at LPC, initiated contact with
    Calibration, Alignment, Database (CalAliDB)
    working group
  • leadership Lee Lueking (FNAL)
  • Oliver Buchmüller (CERN)
  • Now Tri-weekly meetings on alignment DB issues
  • Muon Barrel Link people also participating
  • attempt to unify alignment software for
  • tracker and muon as much as possible
  • Fl. Tech working with Lee Luekings group

19
Data Structure Flow
As of October 2005
(auto-conversion of existing ascii geometry
from old COCOA version Pedro Arce)
CSC Alignment object contains chamber
offsets ?xi ?yi ?zi ?ai ?ßi ??i...
(Fl. Tech)
(Fl. Tech)
(Fl. Tech)
Magnet-off Photogrammetry Survey data
MUON TRACKS
(by hand Dave Eartly?)
(by hand - Fl. Tech)
20
Integrated some analog sensors into COCOA
Note Sensor sizes greatly exaggerated for
visibility
SLM
z
DCOPS
R-sensors
Representations of R-sensors
front CSC
SLM reference
Visualization output from COCOA alignment model
back CSC
Samir Guragain, MH LPC July 2005
21
To do list
  • Produce COCOA version in CMSSW (P. Arce)
  • Develop COCOA-IN COCOA-OUT (Fl. Tech
    tracker?)
  • Transform calibration data, sensor data,
    geometry, survey data into database formats for
    use by COCOA
  • Have started w/ strawman table for analog sensor
    calibration
  • Need to verify nominal COCOA geometry against CAD
    files and actual nominal on-detector geometry
    (Fl.Tech D. Eartly)
  • Understand COCOA performance for ME with magnet
    test data
  • create alignment object as output for offline
    reco use

22
Magnet test
  • Main goal (in my opinion) Get good data !
  • Mostly analyze it later
  • Ensure that ME alignment system is fully
    instrumented and can be read out
  • Planning to send Fl. Tech grad student Samir
    Guragain to CERN for 5-6 months in January 2006
    to help commission read-out
  • get MO support from Giorgio to do so
  • Magnet-off photogrammetry (Dave Eartly)

23
Magnet test contd
  • Test basic functionalities first
  • Do the controls work (e.g. lasers for SLMs) ?
  • Does the readout work?
  • Do raw sensor readings make sense
  • (magnet off vs. magnet on) ?
  • Does the raw data get written out properly in
    event data format ?
  • Suggested alignment exercise
  • Move disks relative to each other and relative to
    barrel by few mm and detect with Z-sensors
  • with magnet off (is this even possible?)

24
Magnet test contd
  • Output parameters from COCOA fits for
    reconstruction
  • 6 parameters per chamber
  • ?x, ?y, ?z displacements of chamber centers
  • ?a, ?ß, ?? rotation of chambers
  • Currently no plans to align at a lower level
    (strips, wires) with the hardware alignment
    system. Maybe later we can get more sophisticated
    once the basics are under control.

25
Summary Outlook
  • Calibration of Clinometers and Z- sensors done.
    Keep on calibrating R- and PX. Finish soon !
  • Software side of alignment gaining momentum.
  • Jump into it full-time as soon as hardware done.
  • Lots to do.
  • Help commission alignment DAQ at CERN starting
    early 2006.

26
Loosely related news
Friday afternoon
Florida Tech
Write a Comment
User Comments (0)
About PowerShow.com