Exp 2' Electrolysis, the Faraday and Avogadro's number - PowerPoint PPT Presentation

1 / 14
About This Presentation
Title:

Exp 2' Electrolysis, the Faraday and Avogadro's number

Description:

Avogadro number is the number of atoms or molecules in one mole. Apparatus ... We can find out the Moles of H2 produced. Q(c) = I(A) * T(s) ... – PowerPoint PPT presentation

Number of Views:265
Avg rating:3.0/5.0
Slides: 15
Provided by: genchemi
Category:

less

Transcript and Presenter's Notes

Title: Exp 2' Electrolysis, the Faraday and Avogadro's number


1
Exp 2. Electrolysis, the Faraday and Avogadro's
number
  • Lab 406, 2 students

2
Introduction
  • Electrolysis of water
  • Anode (oxidation) 2H2O (l) ? O2 (g)
    4H (aq) 4e-
  • Cathode (reduction) 2H2O (l) 2e- ? H2
    (g) 2OH- (aq)
  • Faradays constant
  • F NA e ( NA Avogadros number
  • e Elementary
    charge )
  • Avogadros number
  • Avogadro number is the number of atoms or
    molecules in one mole

3
  • Objective

To determine the values for the faraday and
Avogadros number by Electrolysis
  • Apparatus
  • DC source, insulated copper wires,
  • timer, barometer, 50mL buret, 250mL beaker,
    ruler, thermometer
  • Chemicals
  • 3M H2SO4 (Caution!)

Continue 150300 mA
Q(c) I(A) t(s)
4
  • Procedures

1. In a 250mL beaker, add 100mL of distilled
water and then 50mL of dilute(3M) sulfuric acid.
2. Fill a 50 mL buret with this solution and
invert it in the solution

Invert
100 mL Water 50mL H2SO4 (total 150mL)
Stir it with a glass rod
5
A square piece of paper (2.5cm X 2.5 cm)
6
3. Attach the copper wire cathode to the negative
terminal of the DC source. And place the other
end uninsulated into the inverted mouth of
the buret.
(-)
()
7
  • Make sure that the bare anode put inside of
    burette.

8
4. The volume of solution in the buret should be
accurately measured
1) Record the time, turn on the DC source, and
record the ammeter reading (It is important to
maintain a steady current)
2) Continue the electrolysis until at least 20mL
of hydrogen has been collected.
3) Note the time when the electrolysis is
stopped.
9
5. Measure of the height of the water column in
the buret above the solution in your beaker.
10
6. Measure the temperature of the acid solution
and obtain the barometric pressure and the vapor
pressure of water at the solution temperature.
11
9.
PH2 Pbarometric- PH2Ocolumn PH2O vapor
PH2O column (height of H2O in mm) / (13.6mm
H2O/mmHg)
PV nRT
We can find out the Moles of H2 produced.
15.
Q(c) I(A) T(s)
We can also find out number of coulombs passed
2H 2e- ? H2 ne- (moles) 2 nH2 (moles)
The number of coulombs(C)
1F (C/mol e-)
ne-(mol)
16.
  • Avogadros number N(electron/mol)

The number of coulombs(C)
Electron numbers
1.6 10-19 C/e-
N (e-/mol)
ne-(mol)
12
Additional Usage Notes
13
Fast-Release Pipette Pump
Fit pipet up to 25mL Flexible elastic
thermoplastic rubber chuck holds pipet snugly for
safe, sure use. -Simply insert pipet into
detachable, cone-shaped chuck with light finger
pressure -To fill, grasp pump in palm of hand
and rotate knurled wheel with thumb -To empty
rapidly, lightly press thumb on quick-release
lever -To empty gradually, rotate wheel -Parts
disassemble for maintenance
14
Safety Wide Mouth Wash Bottle
Labeled Water with Blue Cap Use Distilled
Water ONLY
Labeled Acetone with Red Cap Use Acetone ONLY
Write a Comment
User Comments (0)
About PowerShow.com