HCAL Test Beam Setup_at_ Fermilab
  • A(D)HCAL, ECAL
  • and Tail Catcher
  • in Test Beam User Areas MT6-B3/B4

2
Content
  • AHCAL Layers
  • HCAL Stack
  • HCAL Movable Table
  • HCAL Setup in Test Beam Area
  • HCAL Stack and Tail Catcher
  • HCAL Stack and ECAL
  • HCAL Stack and DHCAL

3
AHCAL Layer Tile 30(30 mm x 30 mm x 5 mm)
scintillator
mirror
wavelength shifter
silicon photo multiplier
4
AHCAL Layer 1-30 (Tile geometry fine)100 x Tile
30
Area dimensions (x/y) 300 x 300 mm²
5
AHCAL Layer 1-30 (Tile geometry fine) 100 x Tile
30 96 x Tile 60
Area dimensions (x/y) 660 x 660 mm²
6
AHCAL Layer 1-30 (Tile geometry fine) 100 Tile
30 96 Tile 60 20 Tile 120
Tile area dimensions (x/y) 900 x 900 mm²
7
AHCAL Layer 1-30 (Tile geometry fine) complete
with spacers
limited Scan Area 600 mm x 600 mm defined by Test
Beam Area MT6-B3 based on DESY safety rules
8
AHCAL Layer 1-30 (Tile geometry fine) all tiles
in the Cassette frame
Cassette frame max. dimensions (x/y/z) 1000 x
1000 x 12 mm³
9
AHCAL Layer 1-30 (Tile geometry fine) all tiles
in the Cassette and cabled
light fibres
readout cables
10
AHCAL Layer closed Cassette with electronic
housing
Calibration and Monitoring Board (suppressed) max.
dimensions (x/y/z) 1000 x 100 x 28 mm³
Very Front end Electronic max. dimensions
(x/y/z) 1000 x 300 x 28 mm³
11
AHCAL Layer between 2 absorber plates (steel)
(suppressed CMB)
VFE
absorber plate dimensions (x/y/z) 1000 x 1000 x16
mm³
12
AHCAL Layer 1inside the complete Absorber Stack
(suppressed CMB)
Layer 1
38 pieces of 16 mm thick absorber plates with a
14 mm gap between the plates forms the Absorber
Stack
13
AHCAL StackLayer 1-38 inside the complete
Absorber Stack
Layer 1-38
(suppressed CMB)
AHCAL Stack max. dimensions (x/y/z) 1400 x 1000 x
1140 mm³
14
AHCAL Stackmounted in the Stack Support
(suppressed CMB)
Stack Support max. dimensions (x/y/z) 2560 x 1300
x 1600 mm³
15
AHCAL Stackdismounting a Layer from the Stack
horizontal
(suppressed CMB)
2. Pull out Layer (Cassette with VFE)
1. Remove CMB
16
AHCAL Stackdismounting a Layer from the Stack
vertical
(suppressed CMB)
3. lift Layer (Cassette with VFE)
17
HCAL Movable Table (old version) with HCAL
Stack Support (old version)
Required Capabilities - 500 mm on x axis -
500 mm on y axis 35 around y axis 90
around x axis
18
HCAL Movable Table (old version) HCAL Stack
Support (old version) in cosmic test mode
Stack rotated by 90 around x-axis
19
HCAL Movable Table (old version) HCAL Stack and
beams
IHEP beam height 2150 mm
Fermilab beam height _at_ MTB-6 B3 1650 mm
20
HCAL Movable Table (new version) HCAL Stack and
MTB6 beam
Reduced Capabilities - 300 mm on x axis - 300
mm on y axis 35 around y axis
21
HCAL Movable TableHCAL Stack Support and Turning
Device
Turning Device needs a crane to rotate the Stack
Support
Not possible in the test beam area !
22
HCAL Movable Tablerotated HCAL Stack Support and
Turning Device
Stack rotated by 90 around x-axis
Not possible in the test beam area !
23
HCAL Movable Tablerotated HCAL Stack 35 around
y-axis
24
HCAL Setup in test beam areaFermilab test beam
area MTB6
HCAL Movable Table
2D drawing from the MTB webpage
25
HCAL Setup in test beam areaconversion to metric
and some guesses
3D information about the beam together with old
webpage only!
HCAL Movable Table placed in MTB6-B3
26
HCAL Setup in test beam areaguess 3 Meter inner
height
dump
shielding concrete
roof support
27
HCAL Setup in test beam areaguess roof openings
are projected to 2D drawing
roof opening
28
HCAL Setup in test beam areaguess permanent
closed roof (except openings)
  • installation of Movable Table and Stack with
    tricks only
  • installation of AHCAL Layers in position B3
    critical
  • 90 turning of the Stack not possible No cosmic
    test!

29
HCAL Setup in test beam areaguess roof opening
is big enough
30
HCAL Setup in test beam areaguess crane height
and crane load critical
needed hook height over roof 2.5 m
transport weight 12 tons
31
HCAL Setup in test beam areaguess one escape
route is not sufficient
Escape rote from B4
blocked
32
HCAL Setup in test beam areaECAL and HCAL on
Movable Table and Tail Catcher in MTB6
Tail Catcher
Electronic Racks
HCAL
ECAL
Beam
33
HCAL Stack and Tail CatcherTail Catcher
installed in B3/B4, transport way kept free
transport way
34
HCAL Stack and Tail CatcherHCAL Stack nominal,
Tail Catcher nominal
distance Stack to Tail Catcher 350 mm
35
HCAL Stack and Tail CatcherHCAL Stack rotated
35, Tail Catcher retracted
distance Stack to Tail Catcher 700 mm
36
HCAL Stack and ECALECAL with standalone movable
table
only top part will be fixed on HCAL Stack
37
HCAL Stack and ECALECAL is fixed do the first
absorber plate
ECAL outline
ECAL support
38
HCAL Stack and DHCALDHCAL must fit into the
Stack Support
Problem no DHCAL drawing available
DHCAL has VFE on both sides
existing gap between side plate and absorber
plate is not wide enough
39
Conclusion
  • many Questions
  • sometime many answers
  • but for sure
  • solutions