Title: Ted Berman and Associates, LLC'
1Ted Berman and Associates, LLC.
5401 Collins Avenue, Suite CU11-CMiami Beach, FL
33140(305) 868-4707
- State of Florida Product Approval System
Administrator
2Ted Berman and Associates, LLCFlorida Product
Approval System
Product Approval Administration Team
- THEODORE BERMAN, P.E.
- Product Approval System Administrator
VERDA LA RUEProduct Approval, Process Support
Specialist
SIMON SEGAL, P.E.Assistant Engineer, Product
Application Review
JESSICA HUPPERT Administrative Officer
3Ted Berman and Associates, LLCFlorida Product
Approval System
Each Florida Product application submitted must
be approved by the Florida Building
Commission. The Florida Building Commission
meets approximately every 45 to 60 days.
Please consult the state website at
www.floridabuilding.org to see the list of
meeting dates for the upcoming meetings.
4The BCIS Home Page
5Product Approval Menu
6Overview of the Product Approval Menu
1
7Submit a Product Application
New 9B-72.090
8Submit a Product Application
New
9Submit a Product ApplicationSelect a Compliance
Method
New order of compliance method
10Submit a Product ApplicationSample
Certification Agency Compliance Method (Screen 1
of 4)
New Rule 9B-72
New Validation for Certification Method
11Submit a Product ApplicationSample
Certification Agency Compliance Method (Screen 2
of 4)
New QA Contract Expiration Date
12Submit a Product ApplicationSample
Certification Agency Compliance Method (Screen 3
of 4)
New Evaluation by Third Party/Rational Analysis
Criteria
13Submit a Product ApplicationSample
Certification Agency Compliance Method (Screen 4
of 4)
New
New
New
14New Window Installation Requirements
- Installation instructions for windows including
attachment - at minimum shall include the following
- Type, and grade of anchor, and/or manufacturers
anchor specifications, including minimum nominal
size, minimum penetration into substrate and
minimum edge distances. - 2. Type, physical dimensions, material and grade
of any accessory item or strap, if applicable. - 3. Spacing of anchors, shims, accessory items and
straps. - 4. Illustrated diagrams of the attachment of the
product structure
15Find a Product or Application
16Find a Product or ApplicationSample Completed
Product Application (Screen 1 of 3)
17Find a Product or ApplicationSample Completed
Product Application (Screen 2 of 3)
18Find a Product or ApplicationSample Completed
Product Application (Screen 3 of 3)
19Ted Berman and Associates, LLC
- When submitting applications using the
Certification Mark or Listing Method, verify the
following - Manufacturers name on the BCIS matches the name
on the Certification Agency Certificate. - Model size and performance is an exact match with
uploaded Certification Agency Certificate. - Installation Documents are attached.
- On Limitations of use for each model define use
within HVHZ or outside HVHZ impact, design
rating, missile level and any other pertinent
information. - Testing standards and year of standard as
certified by Certification Agency. If testing
standards are not adopted in the version of the
Florida Building Code, an equivalency of
standards will be required.
20New Rule 9B-72 Changes Validation for
Certification Method
- The Validation process has been added to the
Certification Mark or Listing Method on the
Florida State Product Approval application. - Two types of Validation
- Administrative Validation
- Technical Validation
21New Rule 9B-72 Changes Administrative or
Technical Validation
- Administrative Validation
- If the installation instructions are as
Tested/Certified and are verified by the
Certification Agency, an Administrative
Validation is used.
22New Rule 9B-72 Changes Administrative or
Technical Validation
- If the evaluation report indicates conditions
other than certified by the Certification Agency,
a different application method must be used.
(Evaluation Report by PE/RA)
23New Rule 9B-72 Changes Administrative or
Technical Validation
- Technical Validation (contd)
- Determination that the evaluator has complied
with acceptable standards of engineering
principles. - Engineering verification that the evaluation
complies with the Code. - Copy of the application complying with all
aspects of rule 61G15-36 F.A.C. must be filed
with the Commission.
24New Rule 9B-72 Changes Administrative or
Technical Validation
- Emails sent from BCIS to the Validator will
specify which type of Validation is required and
for Technical Validation, if it is required on
the Installation Instructions, Evaluation
Reports, or both. - Also on the Technical Validation checklists, it
will be specified whether the Installation
Instructions, Evaluation Reports, or both are
required to be Technically Validated.
25New Rule 9B-72 Changes Administrative Validation
Checklist
26New Rule 9B-72 Changes Administrative Validation
Checklist (contd)
27New Rule 9B-72 Changes Technical Validation
Checklist
28New Rule 9B-72 ChangesTechnical Validation
Checklist (contd)
29New Rule 9B-72 Changes Quality Assurance
Expiration Date
- For the Certification Mark or Listing Method, a
new field is added to collect the Expiration Date
of the Quality Assurance Entity Contract on Page
3 of the application. - An email is sent to the Manufacturer with a copy
to DCA when the Expiration Date has passed. - Search criteria on the Product Search web page
allows searching for expired Quality Assurance
Entity Contracts. - Â
30Questions?
- For Product Entity Approval Applications
contact Ted Berman and Associates, LLC - (305) 868-4707.
-
- For Program, Building Code Rule 9B-72 Issues
contact Azhar A. Khan Department of
Community Affairs Codes Standards
Section 2555 Shumard Oak Blvd. Tallahassee,
Florida 32399-2100 (850) 922-1870 www.florid
abuilding.org
31Ted Berman and Associates, LLCNEW Application
Process (beginning NOW!)
- No more recommendation for Conditional Approval
or Deferral. - Applicants work at their own pace to complete
applications by the posted deadline date. - Early submittals will have more correction time,
if needed. - Once Validated, Ted Berman and Associates, LLC
review the application and email the applicant
notifying them of any discrepancies. - Only those applications that are complete are
recommended for Approval to the Product Oversight
Committee (POC) and be listed on the meeting
agenda.
32Ted Berman and Associates, LLC
- Miscellaneous issues
- Make sure your application is Florida Building
Code compliant.
33Ted Berman and Associates, LLC
- Important Code issues (2007 FBC)
- 1702 Definitions Permanent label. A label that
cannot be removed without noticeable damage. - 1714.5.2 Exterior windows, siding and patio glass
doors. - 1714.5.2.1 Testing and labeling.
- Exterior windows and glass doors shall be tested
by an approved independent testing laboratory,
and shall be labeled with an approved label
identifying the manufacturer, performance
characteristics and approved product
certification agency, testing laboratory,
evaluation entity or Miami-Dade Product Approval
to indicate compliance with the requirements of
one of the following specifications - ANSI/AAMA/NWWDA 101/I.S.2 or 101/I.S. 2/NAFS or
AAMA/WDMA/CSA 101/I.S. 2/A440 or TAS202 or TAS
202 (HVHZ shall comply with TAS 202 utilizing
ASTME E 1300-98 or ASTM E 1300-02 or Section
2404).
34Ted Berman and Associates, LLC
- Important Code issues Cont.)
- 1714.5.2.1.1 Test and labeling of skylights.
- Exterior skylights shall be tested by an approved
independent testing laboratory, and shall be
labeled with an approved permanent label
identifying the manufacturer, the products
model/series number, performance characteristics
and approved product evaluation entity to
indicate compliance with the requirements of the
following specification - AAMA/WDMA 101/I.S.2/NAFS, Voluntary Performance
Specification for Windows, Skylights and Glass
Doors, or TAS 202 (HVHZ shall comply with TAS
202).
35Ted Berman and Associates, LLC
- Important Code issues
- 1714.5.4.1 Anchoring requirements.
- Window and door assemblies shall be anchored in
accordance with the published manufacturers
recommendations to achieve the design pressure
specified. Substitute anchoring systems used for
substrates not specified by the fenestration
manufacturer shall provide equal or greater
anchoring performance as demonstrated by accepted
engineering practice. - Note See added Rule 9B-72 requirements
36Ted Berman and Associates, LLC
- Important Code issues
- 1714.5.5.1 Mullions
- Mullions or mulled fenestration assemblies shall
be tested by an approved testing laboratory in
accordance with either AAMA 450, ASTM E330, or
TAS 202 (HVHZ shall comply with TAS 202), or
shall be engineered in accordance with AAMA450
using accepted engineering practice. Mullions
tested as stand-alone units or qualified by
engineering shall use performance criteria cited
in Sections 1714.5.5.2 (load transfer),
1714.5.5.3 (deflection) and 1714.5.5.4
(structural safety factor). Mullions qualified by
an actual test of an entire assembly shall comply
with Section1714.5.5.4, except that mullions in
assemblies - requiring a deflection limitation, as defined in
AAMA/WDMA/CSA 101/I.S.2/A440, shall meet
1714.5.5.2 and 1714.5.5.3. Products not included
within the scope of Section 1714.5.5.1 shall
comply with Sections - 1714.5.5.3 and 1714.5.5.4.
37Ted Berman and Associates, LLCFlorida State
Product Approval
1714.5.3.3.1 Glazed curtain wall, window wall and
storefront systems shall be tested in accordance
with the requirements of this section and the
requirements of the Architectural Aluminum
Manufacturers Association (AAMA) Standard 501,
HVHZ shall comply with 2411.3.2.1.1.
38Ted Berman and Associates, LLC
1609.1.2 Protection of openings. In wind-borne
debris regions, glazing in buildings shall be
impact resistant or protected with an impact
resistant covering meeting the requirements of
SSTD 12, ASTM E 1886 and ASTM E1996, ANSI/DASMA
115 (for garage doors and rolling doors) or
Miami-Dade TAS 201, 202 and 203 or AAMA 506
referenced therein as follows 1. Glazed
openings located within 30 feet (9144 mm)
of grade shall meet the requirements of the Large
Missile Test. 2. Glazed openings located more
than 30 feet (9144 mm) above grade shall meet the
provisions of the Small Missile Test.
39Ted Berman and Associates, LLCFlorida State
Product Approval
40Ted Berman and Associates LLC