1
MIDWEST CONCRETE CONSORTIUM MEETING
  • FALL 2005 MEETING
  • OCTOBER 26 27
  • URBAN RECONSTRUCTION

2
Urban Reconstruction
  • Contractor Incentives/Disincentives
  • Traffic Control Plan is given in the contract.
    Contractor may change order approved
    modifications.
  • Quickchange moveable barrier systems vs. standard
    barrier sections.

3
Materials Issues
  • Air Void Analyzer Update
  • Image Analysis

4
Spacing FactorsAVA vs. ASTM C-457
5
F/T Durability vs AVA Spacing Factor
6
AVA vs ASTM C-457 Correlation
  • Spacing Factor Limit for ASTM C-457 (x) 0.008
    inches.
  • Spacing Factor Limit for AVA (y) 0.015 in.
  • AVA Correlation Equation
  • Y 1.4715x 0.0035 (R2 .9271)
  • X (0.015 0.0035)/1.4715 .0078

7
Image Analysis Update
  • Delayed mostly due to MoDOT reorganization.
  • There are a few issues to work out with
    Honeywell, but no time spent on wrapping the
    project up.