Title: MSFC CSiC Preliminary Cryogenic Optical Testing Data Review


1
MSFC CSiC Preliminary Cryogenic Optical Testing
Data Review
  • James Hadaway, Joseph Geary, Patrick Reardon,
    Bruce Peters, Phil Stahl, Ron Eng, Barry Hale,
    Jeff Kegley Mark Baker
  • The University of Alabama in Huntsville
  • Marshall Space Flight Center
  • May 9, 2001

2
Outline
  • Optical Testing System
  • Early Results
  • Early Conclusions

3
General System Layout
4
PhaseCam Pallet
  • PhaseCam instantaneous phase-shifting
    interferometer with F/33 diverger.
  • Reference sphere for subtraction of instrument
    errors.
  • Intelliwave software.
  • Leica Disto Pro distance meter.
  • Located on 5-DOF platform.

5
Definitions
  • Total or Raw Results - basic Wavescope output
    that has piston, tilt, focus removed.
  • Zernike Fit - fit of first 36 terms.
  • Residual - difference of Total Zernike Fit.

6
PV Cryo Deformation vs. Temperature
7
RMS Cryo Deformation vs. Temperature
8
PV Residual Cryo Deformation vs. Temperature
9
RMS Residual Cryo Deformation vs. Temperature
10
CSiC Ambient Cryo Figure
11
CSiC Cryo Deformation
12
Observed PhaseCam Repeatability
  • Performed two measurements (average of 50 frames)
    at each temperature.
  • Performed difference of two measurements at each
    temperature in order to look at repeatability in
    the operational environment.
  • Average difference/repeatability seen during this
    test was ?/33 PV ?/400 rms (HeNe).
  • In process of conduction more rigorous accuracy
    repeatability characterization.

13
Conclusions
  • In process of analyzing data from first cryo test
    of IABG CSiC mirror at MSFC.
  • Effort has led to early development of PhaseCam
    measurement procedures in advance of AMSD testing.

14
Contacts
  • hadawayj_at_email.uah.edu
  • phil.stahl_at_msfc.nasa.gov