Design of Evacuation System for HighRise Building - PowerPoint PPT Presentation

1 / 8
About This Presentation
Title:

Design of Evacuation System for HighRise Building

Description:

Express emergency shaft transit from refuge place to ground lobby in a non-stop fashion ... Water tolerance parts, Emergency power if main power fails ... – PowerPoint PPT presentation

Number of Views:1429
Avg rating:3.0/5.0
Slides: 9
Provided by: peter259
Category:

less

Transcript and Presenter's Notes

Title: Design of Evacuation System for HighRise Building


1
  • Design of Evacuation System for High-Rise
    Building
  • Danqing Yu

2
Overview
  • 30-years policy of US codes against use of
    elevators in fires Attitudinal impediment
  • Focus of current design number, width and
    position of stairs Is it adequate?
  • Current use of elevator Provide emergency use
    for firefighters and the disabilities
  • Move large number of people from significant
    height Call for safe and reliable elevator
    egress system
  • Future trend design elevators with emergency
    mode
  • ( withstand heat, smoke, water, power-cut)

3
Evacuation Plan for High-Rise Building
  • Normal high-rise building
  • Evacuation sequence emergency floor upper
    floors lower floors
  • Whether or not the elevators attend to disabled
    population first before they serve others
  • Trained personnel to lead evacuation and good
    interface design ( switching driving mode for
    different emergencies)
  • Mega high-rise building
  • Elevators and refuge place are zoned vertically
    by sections
  • Occupants are regularly trained for evacuation
  • Express emergency shaft transit from refuge place
    to ground lobby in a non-stop fashion

4
Buildings Types Need Emergency Elevators
  • Residential Building
  • Buildings with more than 100 persons per floor
    and with more than 50 floors
  • Buildings with more than 200 persons per floor
    and with more than 20 floors
  • Office Building
  • Buildings with more than 50 floors and more than
    50 persons per floor
  • For 15-20 floor building, population per floor
    exceeds 100

5
Parameters for Evacuation System
  • Parameters of Building Evacuation Traffic Flow
  • Building population
  • No. of floors f (1? f ? F)
  • Average passenger walking speed (0.50.75m/s)
  • Passenger density during emergency (1
    person/0.46m2)
  • Configuration for Evacuation System
  • Proportion of population evacuated by stairs and
    elevators
  • Width of evacuation doors (gt 0.8m)
  • Width and travel distance of stairs
  • Positions of stairs and lobbies
  • Size of the lobbies
  • Emergency elevator configuration (number, safety
    mode, driving speed, group control logic )

6
Statistical Method
7
(No Transcript)
8
  • Safety regulation
  • Emergency mode for elevators
  • Water tolerance parts,
  • Emergency power if main power fails
  • Enclosed lobby on each floor of the building,
    elevator should be installed in smoke-proof shaft
    ? 1 hour fire resistance and pressurized against
    smoke infiltration.
  • Real time monitoring of elevator system status
    and any conditions that may threaten its safe
    operation.
  • Max No. of elevators and stairs
  • The number of floors in each elevator zone ? 15
    16 floors
  • Layout of elevators and stairs
  • Typical building 3000 m2 of floor space, 500 m2
    core area (including elevator, 2 stairs 1.2 m
    each) Stairs are located diagonally across the
    core area from each other.