Title: ASSA
1?????????? ??????????? ?????? ASSA
2Fundamental demands for evacuation
- Minimum two, of each other independent, escape
routes - Door should be opened outwards in the exit
direction - Easy to identify as a exit door
- Always possible to open by easy manoeuvrable
accessories
EXIT
3What creates a need of evacuation?
- Fire
- Smoke
- Gas leak
- B mb threat
- Explosion
- Robbery, assault
- Electrical failure, darkness
- Consider also other business and activities in
the area
4The right product in the right place
- The authorities demands / Number of persons in
the room - Visitors knowledge of the facilities and escape
routes - Physical ability of the user
- Light conditions in case of electric failure
- Shape of the facilities
- Risk of explosion
- Grade of intoxication
- Possibility to re-entry
5The right product in the right place
- Re-entering
- When outer door not are visible from the exit
door - Risk of meeting smoke or fire in the escape route
- Risk of frost-bite after evacuation
- Gives possibility for quick entering to the fire
fighters
6Human behaviour
- Even if.
- there are many exit doors out from the
facility, most of the people prefer to use the
same way as they entered - Therefore
- Even if emergency exit devices are used on the
exit doors, always consider use of a panic exit
device on the main entrance door
7Secured function
What can be a secured function?
- Light
- Cash register
- Entrance door
- Computer
- The staffs time clock
- Always discuss with local fire dept!
8Secured function
- Gives a combination of security, safety and
convenience - Why secured function?
- To insure that the exit door is unlocked when the
purpose of the door is changing from
night-security to become an exit door during the
daytime. - An exit device is always possible to open without
a key from the inside - When high security locking is needed, it must be
connected to a fail-safe system - Normally by a micro-switch in the lock case
9Definitions
- Panic exit devices
- - Panic bars according to EN 1125
- Emergency exit devices
- - Exit devices with one hand manoeuvring
according to EN 179 - Other accessories for door opening
- - Thumbturns, handles, break-dome thumbturns
and other - exit devices which not corresponds with
demands in - EN 1125 or EN 179
10 EN 1125 ? EN 179
- ??? ??????????? ?????????, ????????????
- ????????? ????????? ?????????
- 1. EN 1125 ?????????????? ????????????
????????? ????????? ?????????, ????????????? ???
?????? ???????. - 2. EN 179 ????????? ?????????? ??????
?????????????? ? ????? ????????? ????.
11EN 1125 ??????????
- ????????? ??????????? ??????????? ? ?????????.
- ????????????? ?????? 100 000 ??????
(Assa 1125 200 000 ?????? ). - ?????????????? ????? ? 100 ??.
- ?????????????? ???????? ?????? ????????? ???
??????? 60 ?? ?????? ?????. - ????????????? ??? ???????? ?? ?????.
- ???????????? ? ???????.
12EN 1125 Demands
- Without pressure on the door
- Max 8 kg pressure on bar to open
-
-
- With 100 kg pressure on the door
- Max 22 kg pressure on bar to open
13EN 179 ??????????
- ?????????????? ????? ????????? ????.
- ?????????????? ????? ? 100 ?? ?? ???????????
?????. - ????? ??????????? ?????.
- ????????????? ?????? 100 000 ??????.
- ???????????? ? ???????.
- ?????????? ??????????? ????????.
14EN 1125 ? EN 179
- ????????? ????????? ?????????????? ????????? ?
?????? ?? ???????????? ? ????????????. - ????????? ????????? ?????????, ?? ?? ??
?????????????.
15????????????? ?????????????? ??? ????????? ??????
- ASSA 8563
- ??? ????????? ?????? Assa 8561
- ?????? ????????????? ????? ?? ??????????
- ??????? ??????????? ?????????, ?????? ???
????????????? ?????
- ASSA 8560
- ??? ????????? ?????? Assa 8560 ??? 8564
- ?????? ????????????? ?????????? ????? ??
??????????, ??????????? ?? ?????? ???????? - 8560-2 ???????????? ????????????? ??????????
????? - 8560-4 ?????? ????????????? ?????????? ?????,
??????? ??????
16????????????? ?????????????? ??? ????????? ??????
- ASSA 8061
- ??? ????????? ??????
- ??????????? ?? ?????? ????????
- ASSA 8567
- ??? ????????? ?????? 8568
- ??????? ??????? ? ?????, ?????? ???????, ????? ?
????????????? ????? - ????? ?????????? ????????????? ?????? ?????
???????? ???????? - ??????????? ????????? ? ?????? ?????
- 18567 - ????????????
17????????????? ?????????????? ??? ??????????????
??????
- ASSA 8363
- ??? ?????????????? ?????? 1361
- ?????? ????????? 8, 12, 16, 20 mm
- ?????? ????????????? ????? ?? ??????????
- ??????? ???????
- 8364 ??????? ??????????? ?????????, ??????
????????????? ????? - 18363 ???????????? ????????????? ?????
- ASSA 8362
- ??? ?????????????? ??????
- ?????? ????????????? ?????????? ????? ??
??????????, ??????????? ?? ?????? ????????
18????? ?????????? ??? ?????????? ??????
19ASSA 1125
- ???????? ??????????? ????????? EN 1125.
- ????????? ???? Assa 1525 ??? 1526.
- ??????? ???????????? ???????
- ??????????.
- ??????????? ?? ????????? ????????? ?? ????????
??????. - ??????????? ??????? ? ????????? ????? ?????????
???????? 3325. - ??????? ???????? ??????
- ??????????? ?????.
- 11251 ??? ????????? ????????? ??????.
20ASSA 1125
21??? ASSA1125
1525
1526
22ASSA 1130
- ???????? ??????????? ????????? EN 1125.
- ?????????????? ?????? Assa 1326.
- ??????????? ?? ????????? ????????? ?? ????????
??????. - ??????? ???????? ??????
- ??????????? ????????????? ?????????? ???
?????????????? ????. - ??????????? ?????.
- 11301 - ??? ????????? ?????????????? ??????.
23????????? ??? ?????????????? ??????
- ????????? ?????? ?????????????? ?? ??????????????
??????. - ????????? ??? ????? ? ??????????? ?? ????????.
24Where to use a Assa Panic Exit Device?
In large public facilities for more than 150
persons where you can expect a situation of
evacuation in a disorder
- For example
- Cinemas
- Theatres
- Shopping centres
- Sport arenas
- Schools
- Discotheques
- Big restaurants
25Benefits with Assa Panic Exit Devices
- Corresponds to the demands in EN 1125
- Modular or narrow lock case Less impairment on
a approved fire-door - Microswitch on panic bar as standard
- Door closing function for fire-cell
- Stainless steel
26When you order a panic exit device
- Single or double door?
- Is there demands for panic exit devices on both
halves of the double door? - Modular- or narrow profile door?
- Left or right?
- Door width?
- Function on outside? Need for re-entering
accessories?) - Door-height? (Passive half)
- Height to lock case? (Passive half)
- Correct lock case depending on fire cell or not
- Co-ordinator / Pusher?
27Assa 179
- ???????? ??????????? ????????? EN 179.
- ?????????????? ????? ?????.
- ????????? ???? ? ??????? 21mm.
- ???????? ???????? 4. ??????.
- ??????? ??????? ?????? ???????.
- ???????????.
- ??????????? ??????? ? ????????? ?????.
- ??????? ???????? ??????.
- ??????????? ?????? ?? ?????.
28Assa S 3
- ???????? ??????????? ????????? EN 179.
- ?????????????? ????? ????????? ????.
- ?????????????? ???????? ????.
- ???????????.
- ??????????? ??????? ? ????????? ?????.
- ??????? ???????? ??????.
- ??????????? ?????? ?? ?????.
29Where to use Assa 179 and S 3?
- In areas up to 150 persons where you can expect
a situation of evacuation in a good order
30Benefits with Assa 179 and S 3
- Corresponds to the demands in EN 179
- Modular or narrow lock case Less impairment on
a approved fire-door - Microswitch available
- Door closing function for fire-cell
- Available in different finishes
31Automatic Door Sill Assa T 100
- Approved by Swedish authorities in class EI
30/30dB - Fire-resistant special silicon
- Adjustable for door chink from 5-20 mm
- Suitable for
- -
Hospitals - - Elderly homes
- - Stores / Loading
bridges - - Restaurants
- - Schools
- - Handicap
adjustments - - Use of floor cleaning machines
32Other accessories for fire control
- Emergency opening button
- Flush-bolts automatic, micro-function
- Automatic door sill
- Pusher for double doors
- Panic exit device for high voltage rooms
33 Some examples about technical solution
34 Some examples about technical solution
35 Some examples about technical solution
36 Some examples about technical solution
37 Conclusion
- There are standards how to use Panic Exit Devices
- But you should also count on your conscience
- The right product to the right place- be sure of
this! - You will be responsible for the safety of the
customer.