Title: SMT Detector Inefficiencies
1SMT Detector Inefficiencies
Simon Dean
University of Manchester
Monday 16th December 2002
2Monday 16th December 2002
Simon Dean - SMT Detector Efficiencies
Topics
- The Event Sample Used
- Data Extraction Procedure
- Efficiencies
- Looking at inefficiencies
This Talk
http//www-d0.fnal.gov/sdean/talks/SMTefficiencie
s2.ppt
3Monday 16th December 2002
Simon Dean - SMT Detector Efficiencies
Data Sample
- Run 169183
- Taken last Thursday (12/12/2002)
- 20000 events recoed so far (482000 total.)
- Dead/Disabled/Noisy statuses grabbed.
- p13.04.00 reco version
4Monday 16th December 2002
Simon Dean - SMT Detector Efficiencies
Data Extraction Procedure
5Monday 16th December 2002
Simon Dean - SMT Detector Efficiencies
Unpacking-Based Efficiency
Modified unpacking output - strip no., hits,
status Database information SMT mask of
theoretical maxima
6Monday 16th December 2002
Simon Dean - SMT Detector Efficiencies
Barrel 1 Mask
7Monday 16th December 2002
Simon Dean - SMT Detector Efficiencies
Tracking Based Efficiencies
- p13.04.00 tracking
- Tracks require
- gt 5GeV pT
- At least 2 other 2d hits in SMT
Resolutions -1d hits (associated and
non-associated) matched to track crossing position
barrel p-side resolution 17.8µm
8Monday 16th December 2002
Simon Dean - SMT Detector Efficiencies
Tracking Based Efficiencies
Locate closest cluster in detector track
position - 1d cluster centroid lt (5
resolution) HIT
9Monday 16th December 2002
Simon Dean - SMT Detector Efficiencies
Comparison
Looked for big efficiency differences
10Monday 16th December 2002
Simon Dean - SMT Detector Efficiencies
Mini Event Display
- Uses cluster based information ( no 'unassociated
tracks'!!!) - Events contain ³1 high-pT tracks with at least 2
other 2d SMT hits - Selected B1-1-4
- UB efficiency 99.74
- TB efficiency 68.35 (139 crosses, 95 matches)
- 10 of 44 inefficiencies seen here
HIT
11Monday 16th December 2002
Simon Dean - SMT Detector Efficiencies
Example of a Miss
12Monday 16th December 2002
Simon Dean - SMT Detector Efficiencies
Another Example of a Miss
13Monday 16th December 2002
Simon Dean - SMT Detector Efficiencies
Yet Another Example of a Miss ( Hit)
14Monday 16th December 2002
Simon Dean - SMT Detector Efficiencies
To Do...
- 'Empty' detectors
- Quantify trends (ie.. layer averages)
- 1d detector behaviour
- Direct comparison with 2d hit data
- Exclude inefficient strips
15Monday 16th December 2002
Simon Dean - SMT Detector Efficiencies
16Monday 16th December 2002
Simon Dean - SMT Detector Efficiencies