Energy Saving Solutions - PowerPoint PPT Presentation

1 / 14
About This Presentation
Title:

Energy Saving Solutions

Description:

Energy Saving Solutions – PowerPoint PPT presentation

Number of Views:108
Avg rating:3.0/5.0
Slides: 15
Provided by: mattlon
Category:

less

Transcript and Presenter's Notes

Title: Energy Saving Solutions


1
Energy Saving Solutions (Click on pictures) The
Bond Group Bond House New Road Sheerness Kent ME12
1BB Sheerness Branch 44(0)1795
668515 Northern Branch 44(0)1782
563747 Scottish Branch 44(0)1324 558844 Swindon
Branch 44(0)1793 420700
Home
2
Energy Saving Fans EC (Electronically Commutated)
  • Example
  • Typical 8" Shaded Pole Evaporator Fan (most
    common)  38w
  • EC 8" Energy Saving Mo tor 9w
  • Features
  • Large energy savings
  • Quieter operation
  • DC motors with integrated AC to DC conversion
  • Maintenance free
  • Longer service life
  • One fan with variable speed range
  • On site conversion available

Click for website www.bond-group.com The Bond
Group, Bond House New Road, Sheerness, Kent ME12
1BB 44(0)1795 668515
Example taken from www.ecgiants.com
3
LED Light Tubes
  • Example
  • Standard 4ft Fluorescent Tube  36w
  • 4ft LED Tube 16w
  • Features
  • Instant light from cold start
  • No separate power supply (easy installation)
  • Energy Carbon Clean or ECC
  • Low Up Front Cost/Fast ROI
  • Cuts Light Energy Consumption up to 65
  • Rated to 80,000 hours of Useful Life
  • No Mercury or Hazardous Gas
  • Easy to Retrofit
  • Will not Dim Over the Life of Product
  • Various Light Angle Throws Colours Available
  • Fits in Standard T8 Fixtures
  • No Ballast Required
  • UL CE Approved
  • Application
  • General lighting
  • Architectural lighting
  • Retail store lighting
  • Office lighting
  • Refrigeration display case lighting

Specification Operating temperature -30ºc to 50ºc
Click for website www.bond-group.com The Bond
Group, Bond House New Road, Sheerness, Kent ME12
1BB 44(0)1795 668515
4
BUN (Bond Ultrasonic Nebuliser)
  • Example
  • Electric condensate heater 700 to 1000w
  • BUN 70w
  • What is a BUN?
  • A low energy condensate removal system (for
    integral refrigerated display cabinets)
  • Incorporating ultrasonic technologies
  • Dissipating condensate water collected from the
    evaporator following a cabinet defrost
  • Alternatives include
  • high wattage electrical heaters
  • water pumps which need to be connected to
    external drainage.
  • Features
  • Large energy savings up to 93
  • Retrofit to existing equipment

Click for website www.bond-group.com The Bond
Group, Bond House New Road, Sheerness, Kent ME12
1BB 44(0)1795 668515
5
Sliding Cold Room Door Closer
Example Cold room with door closed after use
20kWh/24h Cold room with door open 29kWh/24h
Bond Cold Room Door Closer 0w (Energy saving
of 31 in this example)
  • Features
  • Energy savings due to door not being left open
  • Easy on site retrofit.
  • No Electrical connections
  • Hold open facility
  • Smooth closing action

Click for website www.bond-group.com The Bond
Group, Bond House New Road, Sheerness, Kent ME12
1BB 44(0)1795 668515
6
Glass Door Film
  • Example
  • Typical Frozen 4 Door FGD frame and door
    heaters  1100w
  • Typical Frozen 4 Door FGD frame and door minus
    glass heaters  700w

Low Temp cabinet door with film fitted
  • Features
  • Ideal solution to address condensation and
    improve merchandising for glass door cabinets.
  • Reduce Energy costs up to 37 by eliminating the
    need to heat glass.
  • Scratch, mar and chemical resistant.
  • Easy application to retrofit units in the field.
  • Printable for in store branding inks.
  • Good optical clarity
  • Description
  • One-side coated polycarbonate film
  • Adhesive backing
  • Long-term anti-fog performance
  • Abrasion resistance
  • Impact resistance

Low Temp cabinet door without film fitted
Click for website www.bond-group.com The Bond
Group, Bond House New Road, Sheerness, Kent ME12
1BB 44(0)1795 668515
7
Canopy Conversion
  • Example
  • 8ft No Canopy Cabinet duty  4kW
  • 8ft Cabinet with Canopy fitted duty 3.5kW
  • Features
  • On site retrofit conversion for minimum
    disturbance.
  • No need to purchase new cabinets and increase
    landfill by disposing of old.
  • Increased energy efficiency due to lower cabinet
    duty.
  • Better product temperatures.
  • In some cases raised evaporating temperatures.
  • Environmentally friendly alternative compared to
    purchasing new.
  • Economical alternative to purchasing new.

Click for website www.bond-group.com The Bond
Group, Bond House New Road, Sheerness, Kent ME12
1BB 44(0)1795 668515
8
Night Blind Installation
  • Example
  • Integral cabinet with no blinds 33.3 kwh/24h
  • Same cabinet with blinds used at night 21.3
    kwh/24h
  • Features
  • 30 - 50 energy savings during non-trading hours.
  • Retrofit to existing equipment.

Click for website www.bond-group.com The Bond
Group, Bond House New Road, Sheerness, Kent ME12
1BB 44(0)1795 668515
9
Coil Technology
  • Example
  • MT Cabinet Evaporating temperature  -12c
  • MT Cabinet with New Evaporator Evaporating
    temperature  -7c
  • Features
  • Increased cabinet efficiency
  • Lower cabinet duties.
  • Higher Evaporating temperatures.
  • Off cycle defrost.
  • Description
  • Copper tubing with an inner groove
  • Corrugated aluminium fins
  • More surface area and better heat transfer
  • Possible to remove defrost heaters from MT
    cabinets
  • Hydrophilic coating available

Click for website www.bond-group.com The Bond
Group, Bond House New Road, Sheerness, Kent ME12
1BB 44(0)1795 668515
10
Riser Conversion
  • Example
  • 8ft No Canopy Cabinet duty  4kW
  • 8ft Cabinet with Canopy fitted duty 3.8kW
  • Features
  • Lower cabinet duties.
  • Reduced cold aisle syndrome.
  • On site retrofit available.

Description One of the most popular designs for
multi-deck display cabinets is to have a low
front to give maximum display area. But this can
increase the duty of the cabinet and the cold
aisle syndrome effect within the store. The
rising energy prices mean that the extra display
area is coming at a cost. A front riser or
glazed thermopane can be retrofitted on site
providing energy savings and less cold air
spilling into the aisles.
Click for website www.bond-group.com The Bond
Group, Bond House New Road, Sheerness, Kent ME12
1BB 44(0)1795 668515
11
CFD (Computational Fluid Dynamics)
The Bond Group has recently invested in CFD
software giving us the advantage of being able to
optimize cabinet design before testing. The
benefits to Bonds product development work as a
result of implementing a CFD solution include
  • Reducing development times and producing better
    performing cabinets
  • The ability to investigate display cabinet
    performance before physical prototyping and
    testing
  • The potential to fully understand the air flow
    and heat distribution within a cabinet, guiding
    design changes in a scientific manner
  • The opportunity to optimize the thermal
    performance of a cabinet, to meet the required
    standards, whilst reducing its overall power
    consumption
  • Using the CFD results to quickly identify those
    designs that are not worthy of physical
    prototyping and testing

Click for website www.bond-group.com The Bond
Group, Bond House New Road, Sheerness, Kent ME12
1BB 44(0)1795 668515
12
R290 Conversion
  • Example
  • Integral cabinet with HFC 22 kWh/24h
  • Same cabinet with R290 19.8 kWh/24h
  • Features
  • Natural Refrigerant
  • Up to 10 more energy efficient
  • Smaller charge
  • Retrofit to existing equipment
  • Description
  • Zero ozone depletion levels
  • Hydrocarbons (HCs) becoming the refrigerants of
    choice
  • Bonds can convert existing integral display
    cabinets to R290
  • No need to replace old cabinets for new

Click for website www.bond-group.com The Bond
Group, Bond House New Road, Sheerness, Kent ME12
1BB 44(0)1795 668515
13
Glass Door Conversion
  • Example
  • Integral cabinet with no doors 24.5 kwh/24h
  • Same cabinet with doors fitted 14.75 kwh/24h

On Site Conversion
  • Features
  • Up to 40 energy savings.
  • Retrofit to existing equipment.
  • Longer service life
  • Reduced maintenance costs

Before
After
Click for website www.bond-group.com The Bond
Group, Bond House New Road, Sheerness, Kent ME12
1BB 44(0)1795 668515
14
Click for website www.bond-group.com The Bond
Group, Bond House New Road, Sheerness, Kent ME12
1BB 44(0)1795 668515
Write a Comment
User Comments (0)
About PowerShow.com