KEK-ICEPP data transfer test - PowerPoint PPT Presentation

1 / 40
About This Presentation
Title:

KEK-ICEPP data transfer test

Description:

Establish a simple data grid bw KEK and ICEPP (U-Tokyo) on ... SPAS,SPOR,ETET, ESTO, SBUF, DCAU. GridFTP. AUTH,ADAT and other RFC959. 2003/7/16. 1st PacifiGrid ... – PowerPoint PPT presentation

Number of Views:25
Avg rating:3.0/5.0
Slides: 41
Provided by: man4150
Category:
Tags: icepp | kek | data | etet | test | transfer

less

Transcript and Presenter's Notes

Title: KEK-ICEPP data transfer test


1
KEK-ICEPP data transfer test
  • ICEPP-KEK CRC collaboration

2
Objective
  • Establish a simple data grid bw KEK and ICEPP
    (U-Tokyo) on Super Sinet WAN.
  • NorduGrid/Globus
  • HPSS data access from NorduGrid
  • Performance test of HPSS over WAN.
  • Transfer LCD-0 data generated by ICEPP PC-farm to
    KEK user.

3
Hardware
4
ICEPP-KEK Grid Test BedHardware
  • Hardwares
  • ICEPP
  • Computing Elements
  • 4 nodes with 8cpus. (Athlon MP 2000 1.7GHz 512M
    mem)
  • KEK
  • Computing Elements
  • 50 nodes with 100 cpus.(PenIII 1GHz 512M mem)

5
ICEPP-KEK Grid Testbed
  • Network
  • 1 GbE connection over Super-SINET between ICEPP
    PC farm, KEK PC farm and HPSS servers in single
    subnet.
  • RTT 4ms / quality is quite good.

6
GRID testbed environmentwith HPSS through GbE-WAN
HPSS servers
ICEPP
KEK
SE
HPSS 120TB
SE
CE
60km
0.2TB
CE
6CPUs
CE
100 CPUs
PBS clients
PBS clients
User PCs
7
Software
8
ICEPP-KEK Grid Testbedsoftware
  • Software
  • Globus 2.2.2
  • Nordugrid 0.3.12 PBS 2.3.16
  • HPSS 4.3 GSI enabled pftp (GSI-pftp)

9
NorduGrid
  • As a Grid middle-ware.
  • NorduGrid (The Nordic Test bed for Wide Area
    Computing and Data Handling)
  • http//www.nordugrid.org
  • The NorduGrid architecture and tools presented
    by A.Waananen et al. _at_ CHEP03

10
Why NorduGrid
  • Natural Application of GLOBUS toolkit for PBS.
  • PBS clients do NOT need Globus/NorduGrid
    installation.
  • We installed NG/Globus to just 3 nodes. (ICEPP
    CE,KEK CE, KEK HPSS SE) but can use more than
    60nodes.
  • Simple, but sufficient functionality.
  • Actually used at ATLAS DC in Nordic states.
  • Good start for basic regional center
    functionality test.

11
HPSS as NorduGrid Storage Element
  • HPSS does not speak Globus. We need something
  • GridFTP for HPSS
  • In design phase at Argonne Lab.
  • Some are also being developed? (SDSC?)
  • GSI enabled pftp (GSI-pftp)
  • developed at LBL.
  • SRB
  • GSI-pftp is not a GridFTP. But.

12
GSI-pftp as NorduGrid SE
  • Both Gridftp and GSI-pftp are a kind of ftp,only
    extended protocols are not common.

GridFTP GSI-pftp
SPAS,SPOR,ETET, ESTO, SBUF, DCAU PBSZ,PCLO,POPN,PPOR,PROT,PRTR,PSTO
AUTH,ADAT and other RFC959
13
GSI-pftp as NorduGrid SE
  • Protocols for parallel transfer and buffer
    management are different.
  • DCAU (Data Channel Authentication) is unique for
    Gridftp. But it is option of user.
  • GSI-pftpd and Grid-ftp client can successfully
    communicate each other excepting parallel
    transfer.

14
Sample XRSL
(executablegsim1) (arguments"-d") (inputfiles
(data.in" "gsiftp//dt05s.cc.kek.jp2811/hpss/ce/
chep/manabe/data2")) (stdoutdatafiles.out) (join
true) (maxcputime"36000") (middleware"nordugrid"
) (jobname"HPSS access test") (stdlog"grid_debug
") (ftpThreads1)
15
Performance measurement
16
Players In HPSS
Disk Mover (Disk Cache)
HPSS server
Computing Element in ICEPP/KEK
Shared by many users
Tape 3590 (14MB/s 40GB)
Disk mover GSIpftp Server
Tape movers
CE (Gridftp client)
2CPU Power3 375MHz AIX 4.3 HPSS 4.3 Globus 2.0
2CPU PenIII 1GHz RedHat 7.2 Globus 2.2
2CPU Power3 375MHz AIX 4.3 HPSS 4.3
Disk mover
17
Possible HPSS Configuration 1
KEK
ICEPP
Super-SINET 1GbE
HPSS Server
Disk Mover
Computing Element
60km
SP Switch 150MB/s
  • Put disk mover (cache) near HPSS server.
  • Cache should be near to consumer but disk mover
    is far from CE.
  • Get high-performance of SP switch.

18
Possible HPSS Configuration 2
ICEPP
KEK
Super-SINET 1GbE
Computing Element
Computing Element
HPSS Server
LAN 1GbE
Disk Mover
  • Put remote disk mover(cache) near CE.
  • Fast access between CE and cached files.
  • If access to the same file from KEK side CE, long
    detour happen.

19
Possible HPSS configuration 3
KEK
ICEPP
Computing Element
Computing Element
HPSS Hierarchy 3
HPSS Hierarchy 2
HPSS Server
HPSS Hierarchy 1
  • To avoid long access delay for CE in KEK, disk
    layer can be divided into two hierarchy. But
    complicated configuration is it.

20
Possible HPSS Configuration 1
KEK
ICEPP
Super-SINET 1GbE
HPSS Server
Disk Mover
60km
Computing Element
LAN 1GbE
  • Current Setup

Computing Element
21
Performance
  • Basic Network performance.
  • HPSS Client API performance.
  • pftp client - pftp server performance.
  • Gridftp client - pftp server performance.
  • HPSS
  • Client API (HPSS orignal)
  • Parallel FTP (HPSS original)
  • GridFTP (by GSI-pftp )

Note
22
Basic Network Performance
  • RTT4ms
  • packet loss free.
  • MTU1500
  • CPU/NIC is bottleneck.
  • Max TCP Buffer Size(256k) in HPSS servers cannot
    changed.(optimized for IBM SP switch)

LAN
WAN
23
Basic network performanceon Super-sinet
Network transfer with of TCP session
  • gt4 TCP session gets MAX transfer speed.
  • If enough TCP buffer size 1 session get almost
    MAX speed.

600
Client Buffer size 1MB
WAN
400
Aggregate Tx speed (MBit/s)
Client Buffer size 100KB
200
ICEPP client KEK HPSS mover

Buffer size HPSS mover 256kB
0
0
2
4
6
8
10
of TCP session
24
Disk mover disk performance
  • HPSS SSA raw disk performanceread/write
    50/100 MB/s
  • PC farms disk performance.Read/write
    30-40MB/s

25
HPSS Client API
LAN
HPSS disk lt-gt CE memory
WAN
26
HPSS Client API
  • NW latency impacts to file transfer speed.
  • Max. raw TCP speed was almost same, but data
    transfer speed became 1/2 in RTT4ms WAN.
  • The reason is not clear yet. But frequent
    communication between HPSS core server and HPSS
    client exists?(every chunk size (4kB) ?)
  • write overhead at single buffer transfer was
    bigger than read.
  • 64MB buffer size was enough for RTT4ms network.

27
Pftpd?pftp HPSS mover disk -gt Client
80
LAN
to client /dev/null
60
WAN
Transfer speed (MB/s)
40
KEK client
20
ICEPP client
ICEPP client Pwidth
0
0
2
4
6
8
10
of file transfer in parallel
28
pftpd-pftp get performance
  • Same as in Client-API transfer, even with enough
    buffer size, transfer speed in WAN is 1/2 of that
    in LAN.
  • Simultaneous multiple file transfer (gt4) gain
    aggregate transfer bandwidth. We had 2 disk
    movers with 2 disk paths each (2x24)
  • Single file transfer with multiple TCP session
    (pftp function (commandpwidth)) was not
    effective for RTT4ms network with enough FTP
    buffer.

29
Pftp?pftp HPSS mover disk Client disk
80
60
to /dev/null
Aggregate Transfer speed (MB/s)
KEK client (LAN)
40
ICEPP client(WAN)
20
Ftp buffer64MB
to client disk
client disk speed 35-45MB/s
0
0
2
4
6
8
10
of file transfer in parallel
Client disk speed _at_ KEK 48MB/s Client disk
speed _at_ ICEPP33MB/s
30
Pftpd?pftp get performance (2)
  • Even if each component (disk, network) has good
    performance. Total throughput becomes bad.
    Because access is done in serial way.

Total speed 1/( 1/100 1/80 1/40) 21MB/s
31
HPSS get with Tape Library
pftp-pftp get performance
  • Thanks to HPSS multi file transfer between tape
    and disk hierarchy, and enough number of tape
    drives, we could get speed up in multiple file
    transfer even if data was in tapes.

tape off drive
300
tape in drive
Data in Tape
200
Elapsed Time (sec)
Data in disk cache
100
data was on HPSS mover disk
data was in HPSS mover mounted tape
data was in HPSS mover unmounted tape
0
0
2
4
6
8
10
of file transfer in parallel
32
pftp?pftpd put performance
1 file N files
Aggregate
N files N files
1 file file (pwidth)
33
GSI pftpd GSI pftp client
  • We compared GSI pftpd GSI pftp client transfer
    with normal kerb-pftp-pftp. Both had equivalent
    transfer speed. Since just initial authentication
    is different, this was likely result.

34
GSI pftpd Grid FTP client
  • We compared GSI pftpd GSI pftp client
    (pwidth1) transfer with GSI pftpd Grid FTP
    client. Both had equivalent transfer speed in
    many cases, but .. The difference bw GSI pftpd
    GSI pftp c and GSI pftpd Grid ftp is a
    feature of parallel multiple-TCP session transfer
    (pwidth gt1). So the result seems reasonable.

35
Gridftp client and GSI-pftp server
disk mver (!pftpd) client pftp-pftpd
disk mver (pftpd) client gridftp-pftpd
disk mver (!pftpd) client gridftp-pftpd
36
GSI-pftpd with Gridftp client
  • It works !
  • But less secure than Gridftp-Gridftpd (omit data
    path authentication)
  • In our environment, GridFTP parallel TCP transfer
    is not needed.
  • With multiple disk mover, all data transfer go
    through single pftpd server. (if use with
    Gridftp client)

37
Gridftp client and GSI-pftp server
disk mver (!pftpd) client pftp-pftpd
disk mver (pftpd) client gridftp-pftpd
disk mver (!pftpd) client gridftp-pftpd
38
Path difference
pftp - pftpd
Gridftp GSI-pftpd
39
Summary
  • ICEPP and KEK configured NorduGrid test bed with
    HPSS storage server over High speed GbE
    WANetwork.
  • Network latency affected HPSS data transfer speed
    especially for HPSS client API.
  • GSI-pftpd developed by LBL is successfully
    adopted to the interface between NorduGrid and
    HPSS. But it has room for performance improvement
    with multi-disk movers.

40
From HPSS developers
  • In case of API client with old version of HPSS,
    flow control in each 4kB data transfer was
    existed to support not only TCP but also IPI3.In
    the present version, HPSS has TCP only mode and
    also using hpss_ReadList()/WriteList() will help
    the performance.
  • In case of pftp access over WAN, pdata-only and
    pdata-push protocol which is introduced since
    HPSS ver.5.1 will increase the performance.