Aspheric IOLs - PowerPoint PPT Presentation

About This Presentation
Title:

Aspheric IOLs

Description:

J. Reiter, B. K lbl. Eye Clinic Landshut, Bavaria, Germany. Comparative Study of Acri. ... Spheric. Optics. foldable single-piece posterior chamber IOL for MICS, ... – PowerPoint PPT presentation

Number of Views:295
Avg rating:3.0/5.0
Slides: 13
Provided by: Rei127
Category:
Tags: aspheric | iols | spheric

less

Transcript and Presenter's Notes

Title: Aspheric IOLs


1
Aspheric IOLs
Comparative Study of Acri.Smart 46S to its
identical aspheric sister-IOL 46LC
  • NO FINANCIAL INTEREST
  • NOT FDA APPROVED
  • J. Reiter, B. Kölbl
  • Eye Clinic Landshut, Bavaria, Germany

2
Comparative Study of Acri.Smart 46Sto its
identical aspheric sister-IOL 46LC
Acri.Smart 46S Acri.Smart 46LC
IOL-Design foldable single-piece posterior chamber IOL for MICS, ø 6.0 mm, plate haptic, overall length 11.5 mm acrylat 25 water content, no angulation foldable single-piece posterior chamber IOL for MICS, ø 6.0 mm, plate haptic, overall length 11.5 mm acrylat 25 water content, no angulation
Optics Spheric Lens Corrected
3
Comparative Study of Acri.Smart 46Sto its
identical aspheric sister-IOL 46LC
Study Design
Patients (eyes)
  • prospective, randomized implantation of 46S and
    46LC in left or right eye
  • two surgeons
  • coaxial mini phaco2.3 mm temporal stab. incision
  • intra-individual comparison
  • 2 mo's post-op clin. outcome, BCVA, wavefront
    analysis (WaveScan), contrast sens. (contrast
    sensitivity tester Model 1800)
  • patient questionnaire

46S / 46LC
n 32
age 76.41 (53 90)
sex 12 m, 20 f
D. M. 14
D. R. 0
OAG (comp.) 4
AMD (mild) 12
4
Randomized Intra-Individual Comparison of
Acri.Smart 46S vs. 46LC
Eyes pre-op. parameters
Eyes intra-op. parameters
46S 46LC
IOP 16.31 ( 3.27) 16.16 ( 2.97)
Ref. sph. 0.84 ( 1.55) 0.98 ( 1.43)
Ref. cyl. -0.56 ( 0.63) -0.55 ( 0.44)
Ref. axis 52.84 ( 51.48) 73.91 ( 56.95)
BCVA 0.36 ( 0.16) 0.38 ( 0.14)
Axial length 23.08 ( 0.57) 23.11 ( 0.56)
46S 46LC
IOL-power (dpt) 21.02 ( 1.43) 18 24 21.13 ( 1.43) 18 24
PC-fibrosis 1 1
PC-rupture 0 0
Impl. / un-fold. comp. 0 0

Mac. edema resolved 0 0
Endophtalm. resolved 1 0
Eyes post-op. parameters
5
Randomized Intra-Individual Comparison Visual
Acuity - BCVA
6
Wavefront Analysis(WaveScan)
p lt 0.001
p lt 0.00001
7
Contrast Sensitivity-Scoring Sheet
Example(Contrast Sensitivity Tester Model 1800)
cpd 1 2 3 4 5 6 7 8 9 Score
A (1.5) L U R U L R L U R 8
B (3) R L R L R U L R U 7
C (6) U R L U R U R L R 6
D (12) L R U R U L U R L 4
E (18) U L R U L R U R U 3
8
Contrast Sensitivity(photopic 85 cd/m²)
9
Contrast Sensitivity(mesopic 6 cd/m²)
10
Contrast Sensitivity-PhotopicIntra-Individual
Comparison
11
Contrast Sensitivity-MesopicIntra-Individual
Comparison
12
SummaryIntra-Individual Comparison