Title: 5F in 6F (7F) technique in DES era
15F in 6F (7F) technique in DES era
(Parent-child catheter technique)
Kyoto 2nd Red Cross Hospital, Japan
Naoto Inoue M.D. FJCC FSCAI
2Key Points in DES era
- Simple procedure is recommended
- Debulking device plays a small role except
calcified or bifurcated lesion - Safe DES implantation is important
3For the DES delivery
- Longer is better ? 23, 28, 33mm stents are
- frequently used
- The deliverability of long stent is not good
especially in the calcified or tortuous lesion
- We need the technique for the safe DES delivery
41 Catheter selection
RCA Amplatz, Hockey, Champ LCA XB, EBU, Amplatz
5 66F EBU catheter
72 Pre dilatation ,pre debulking
Enough predilatation (high pressure, large
balloon) Rotablator (calcified lesion)
8Strong guide cathe, enough pre dilatation,
debulking failed
9Anchor technique
Side branch anchor
Peripheral anchor
10Cross of balloon catheter
LCX guide wire 2.5mm balloon dilatation
LAD CTO
11Cross of balloon catheter
1.5mm balloon pass the lesion
12Anchor technique for CTO
135F in 6F(7F) technique
6F mother cath. (Heartrail Terumo Co.)
6Fgt0.070 inch (Launcher, Heartrail Radiguide)
5F child cath. (20cm longer than mother
cath. Terumo Co.)
145F in 6F technique
Hemostatic valve
Hemostatic valve
Yconnector
Heartrail 5Fr straight
Y connector
Heartrail 5Fr straight
Heartrail 6Fr
Heartrail 6Fr
Hemostatic valve not good
155F in 6F technique
dissection
G.C. 6F Heartrail JL 3.5 G.W. BMW wire
S670 could not cross the lesion
165F in 6F technique
175F in 6F technique
During stenting
Post stenting
Child catheter
Child catheter
Child catheter
Child catheter
Child catheter
18Artery model
19(No Transcript)
20(No Transcript)
21(No Transcript)
22(No Transcript)
23RCA tortuous calcified lesion HD patient
24Two step 5 in 6
25Method of 5F in 6F
26Alternative 5F in 6F (7F) technique
Child catheter goes across the stenotic lesion
No risk of stent dislocation
No risk of DES polymer peeling off
27CABG (LITA?LAD, SVG?PL) Hemodialysis
50 y.o. male
28Child catheter
????
292.5x18mm Cypher
3.0x13mm Cypher
30??
???
31Complication
- Vessel injury
- Air embolism
32Vessel injury
33Air embolism
- We have one air embolism
- Air embolism will occur when child catheter is
wedged - or angiography after stent deployment
-
34Safety use for 5 in 6F technique
- Gently advancement of child catheter into the
coronary - artery
- Careful monitoring distal coronary pressure
- Check the blood back flow from Y-connector just
after - stent deployment
-
35Thank you !!