Title: FPIX0 Electronic Test


1
FPIX0 Electronic Test
  • Marina Artuso
  • Paul Gelling
  • Jianchun Wang
  • The system works fine with charge injection
    calibration
  • Gain curve, threshold, and noise calibration
  • Americium source calibration

2
FPIX0 Chip
3
Gain Curve Calibration
High Gain Cell
  • Scan step
  • 1mV 31.25 e

Normal Gain Cell
4
  • Efficiency curve around threshold
  • can used to measure both noise and threshold

Attenuation factor 0.31826
5
Threshold Distribution
Threshold Voltage set to 1.95 V
6
Noise Distribution
7
Calibration with X-ray Source
  • Americium-241 60 KeV (35.7)
  • Peak expected Q 60 / 3.6 16.7 Ke
  • Charge ADC curve from pulse calibration applied

Number of Clusters
60 KeV peak
Qcluster (Ke)
8
Am-241 with Al Filter
9 mm (later 4 mm) Al filter used lower energy
peak is suppressed
9
Relative Scale Calibration
220,000 Clusters recorded for 11 ? 63 cells
10
Peak Position Distribution
11
Scale Correction
Single Point (60KeV) Calibration ? Scale
Factor only
12
Summary
  • Pulse and source calibrations so far work fine,
    and can be used for future test
  • Strong X-ray source, more point calibration
  • Laser beam is much better choice ( investigating
    )