FCAL Collaboration Meeting - PowerPoint PPT Presentation

About This Presentation
Title:

FCAL Collaboration Meeting

Description:

LumiCal displacement measurement present status. Wojciech Wierba INP PAN. Jerzy Zachorowski UJ ... New lasers with aspherical lenses better spot ... – PowerPoint PPT presentation

Number of Views:24
Avg rating:3.0/5.0
Slides: 15
Provided by: ifj7
Category:

less

Transcript and Presenter's Notes

Title: FCAL Collaboration Meeting


1
LumiCal displacement measurement present status
  • Wojciech Wierba INP PAN
  • Jerzy Zachorowski UJ
  • Wojciech Slominski UJ
  • Leszek Zawiejski INP PAN
  • Krzysztof Oliwa INP PAN
  • Michal Karbowiak

2
Present setup single laser beam
  • BW camera DX1-1394a from Kappa company 640 x 480
    with Sony ICX424AL (70) sensor 7.4 µm x 7.4 µm
    unit cell size
  • Laser module LDM635/1LT from Roithner
    Lasertechnik
  • ThorLabs ½ travel translation stage MT3 with
    micrometers (smallest div. 10 µm)
  • Neutral density filters ND2

3
Single beam setup layout
4
Single beam measurement results I
Y position
Difference beetween points µm
X position
X position
Camera has been translated in 50 µm 2 µm
(estimated error) steps
5
Single beam measurement results II
Y position
Difference between points µm
Difference between points µm
X position
X position
Camera has been translated in 50 µm 2 µm
(estimated error) steps
6
XYZ displacement measurement with two beams
Two laser beams (one not perpendicular to the
sensor) allows us to measure XYZ translation in
one sensor
7
Setup with two beams
8
Z translation of the camera
X and Y position are constant The angle between
two beams is 30
Z 0 µm
Z 250 µm
Z 500 µm
Z 750 µm
Z 1000 µm
Z 1250 µm
Z 1500 µm
9
Proposed setup with two beams and prism splitter
10
Readout electronics for CCD Prototype
11
Readout electronics for CCDanalog part
12
Readout electronics for CCD digital part
13
Conclusions
  • The XY position measurement method with single
    beam has the accuracy better than a few
    micrometers
  • The different XY algorithm and new measurements
    shows similar results
  • The XYZ position measurement with two beams looks
    promising, a new algorithm has been developed,
    results soon

14
Next steps
  • New lasers with aspherical lenses better spot
  • Beam splitter with half transparent mirror
    designed, not ordered yet
  • Setup with two lasers better reliability
  • Improvement of algorithm to determine centre of
    two spots
  • Discussion on possible errors
  • More compact prototype in progress
  • Independent measurement of XYZ translations
    Renishaw industrial system (0.1 µm resolution)
  • Stability tests
Write a Comment
User Comments (0)
About PowerShow.com