Electrical Engineering Department
Electric Generator Done by Abdullah
Al-Hulaimi ID214917 For Dr shwahdi
10 May 2005
2
Electrical Engineering Department
1.INTRODUCTION
10 May 2005
3
Electrical Engineering Department
BACKGROUND
10 May 2005
4
Electrical Engineering Department
TYPES OF GENERATOS
10 May 2005
5
Electrical Engineering Department
AlQURRAH POWER PLANT GENERATORS
6
Electrical Engineering Department
Overview
  • Manufacturer Mitsubishi Heavy Industries
  • Rated Speed 3600 rpm
  • Number of Phases 3
  • Frequency 60 Hz
  • Number of Poles 2 poles
  • Voltage Output (nominal) 2 0 kV
  • Hydrogen Gas Pressure 4.0 barg
  • Apparent Power Output 735,200 kVA
  • True Power Output 625,000 kW
  • Rated Current Output 21,223 amps
  • Power Factor 0.85
  • Excitation Voltage 550 VDC
  • Hydrogen Gas Volume 120 m3

7
Electrical Engineering Department
MAJOR COMPONENTS
8
Electrical Engineering Department
Operation process
  • The magnetic field produced by the stator poles
    induces a voltage in the rotor (or armature)
    coils when the generator is rotated.
  • This induced voltage is represented by a voltage
    source.
  • The stator coil has resistance, which is
    connected in series.
  • The pole flux is produced by the DC
    excitation/field current, which is magnetically
    coupled to the rotor
  • The field circuit has resistance and a source
  • The voltage drop on the brushes represented by a
    battery

9
Electrical Engineering Department
The induced voltage is connected to the generator
terminals through the commutator and brushes
Safety
1.size 2. circuit breaker 3. qualified
electrical contractor 4. NEVER store a generator
near a gas water heater or furnace 5.  NEVER fuel
an electric generator when the generator is
running 6. ALWAYS insure proper ventillation
7.remmember Many engine parts are very HOT
during operation
10
Electrical Engineering Department
Performance Characteristics of Generators
  • No-load characteristics
  • 2. Terminal characteristic of a DC shunt generator

11
(No Transcript)
12
Electrical Engineering Department
THANK YOU