Quick Fixes Helpful Hints
2
Warranty
  • 1 year on parts and labor
  • 5 years on the compressor
  • From the date of original installation on any
    unit.

3
Warranty Procedure
  • You MUST provide
  • Model
  • Serial
  • Place of business
  • Where the unit is located
  • If possible, installation date.

4
Preventative Maintenance
5
Preventative Maintenance
  • Check Condenser
  • Door Gaskets
  • Leveling Casters
  • Air Clearances
  • Calibration of Thermometer
  • Front Breathing
  • Optional Electric Condensate
  • Thermostat Timer Adjustments

6
Preventative Maintenance
Check Condenser
  • Dirty coils cause
  • Increased Energy Use
  • Unnecessary Service Calls
  • Premature Compressor Failure
  • .

Dirty condenser coils are the main reason for
service calls!
7
Preventative Maintenance
Door Gaskets
  • If the door gasket(s) do not seal properly to the
    cabinet face and there are gaps between the
    gasket and the face on the hinge edge, proceed as
    follows
  • For each door, loosen all screws which are
    directed into the edge of the door and push the
    door towards the cabinet eliminating the gap.
    Hold the door firmly in place and tighten all
    screws securely.
  • 2. Replace all snap-on hinge covers.

8
Preventative Maintenance
Installing Condesate Vaporizer
  • IMPORTANT NOTE
  • It is extremely important to be sure that the
    condensate pan is plugged into its correct
    receptacle labeled vaporizer and that the
    condensing unit is plugged into its correct
    receptacle labeled condensing unit.

9
Preventative Maintenance
Leveling of Casters
  • Caster Must be Tight to Cabinet Bottom
  • Do not attempt to level casters by unscrewing
    them from the case bottom as this will cause
    damage to the cabinet bottom and leg hole
    threads, voiding all warranties

USE CASTERS SHIMS IF NEEDED!
10
Preventative Maintenance
Air Clearances
Reach-In Models
Clearance of 12" above the grill and 3" on each
side and back of the cabinet must be provided .
If necessary, special venting or air supply ducts
must be installed by the installer for this
purpose.
11
Preventative Maintenance
Air Clearances
For optimum performance, the cabinet must be
installed on legs or casters and a minimum of 3"
on each side and rear of the cabinet must be
provided.
12
Preventative Maintenance
Calibration of Thermometer
To check calibration, an accurate, mercury
thermometer (within the temperature range of your
model) must be placed inside of the cabinet on
the center shelf for at least 15 minutes without
any door openings.
13
Preventative Maintenance
Front Breathing
14
Preventative Maintenance
Optional Electric Condensate
15
Preventative Maintenance
Thermostat Defrost Timer Adjustments
16
What is NOT Covered?
  • Preventative Maintenance
  • Compressor Failure Due to Poor Air Circulation
  • Temperature Adjustments Calibrations
  • Leveling