UPS series PROTECT 1.M - PowerPoint PPT Presentation

1 / 9
About This Presentation
Title:

UPS series PROTECT 1.M

Description:

UPS series PROTECT 1.M. Scalable UPS in n x technology ... Sags / brownouts. Dynamic overvoltage. Undervoltage. Overvoltage. Lightning. Transients (Surge) ... – PowerPoint PPT presentation

Number of Views:30
Avg rating:3.0/5.0
Slides: 10
Provided by: sbucomp
Category:

less

Transcript and Presenter's Notes

Title: UPS series PROTECT 1.M


1
UPS series PROTECT 1.M
  • Scalable UPS in nx technologyModularity with
    double conversion UPS modules True sine wave -
    output

2
PROTECT 1. modular the new generation
of uninterruptible power supplies (UPS)
3
PROTECT 1.M Comparison to standard UPS systems
PROTECT 1. modular Scalable single-phase
three-phase uninterruptible power supply (UPS)
4
PROTECT 1.M UPS modules from 4 kVA up to 24
kVA
Structure for UPS power module
  • High Power reserves as a result of a max.
    24 kVA total output
  • High Safety reserves as a result of nx
    technology
  • Three phase or single phase connection
    with automatic recognition
  • Independent UPS modules (no central control)
    slide-in types suitable for rackmount

5
PROTECT 1.M n x Redundancy Capacity
nx parallel redundancy
  • Higher reliability
  • Easy to increase overall capacity
  • Modules hot-swappable without any
    interruption

6
PROTECT 1.M Technology
  • double-conversion design ( true online )
  • Classification VFI ( acc. to IEC 62040 3 )
  • Resolves variouspower problems
  • Interruption
  • Weakening
  • Noise
  • Surge
  • Instant voltage drop
  • Thunderbolt
  • Transients changes
  • Frequency changes

7
PROTECT 1.M UPS classes
Voltage Phenomenon
Time e. g. IEC
UPS solution



62040-3
1. 2. 3. 4. 5. 6. 7. 8. 9. 10.
Outage - blackouts Sags / brownouts Dynamic
overvoltage Undervoltage Overvoltage Lightning Tra
nsients (Surge) Frequency variations Voltage
distortion (Burst) Voltage harmonics
gt 10 ms continuous continuous sporadic lt 4
ms sporadic periodic continuous
VFD Voltage Frequency Dependent VI Voltage Indep
endent VFI Voltage Frequency Independent
Classification 3 Offline Classification
2 LineInteractive Classification 1 (true)
Online real Double- Conversion
Publication by ZVEI UPS Guide
........... by additional
lightning arrestors
8
PROTECT 1.M Power connections
INPUTSingle phase Three phaseautomatically
selfrecognize OUTPUTSingle phase
INPUT ( Load ? 70 )1ph 140 Vac 300
Vac3ph 242 Vac 520 Vac OUTPUT1ph 230 Vac
2
9
PROTECT 1.M Operating LCD Display
10
PROTECT 1.M Autonomy time table
1BatteryCabinet
Battery Capacity
Autonomytime
Battery Capacity
Autonomytime
11
PROTECT 1.M Communication interface
Dual monitoring interface
Expansible - AS/400 card (dry contacts)
- SNMP card (with connector for
additional temperature measurements
and intelligent load switch)
Write a Comment