X-band-RF%20Performance%20Requirements - PowerPoint PPT Presentation

About This Presentation
Title:

X-band-RF%20Performance%20Requirements

Description:

Structure Power. 0.5 deg* deg. 160. fx. Deccelerating Phase. symbol. Tolerance (critical) ... Pulse-to-pulse rms stability tolerance ... – PowerPoint PPT presentation

Number of Views:32
Avg rating:3.0/5.0
Slides: 2
Provided by: heinzdie
Category:

less

Transcript and Presenter's Notes

Title: X-band-RF%20Performance%20Requirements


1
X-band-RF Performance Requirements
250 MeV
Parameter symbol Target (Nom.) Upper Limit Lower Limit Units Tolerance (critical)
Structure Length Lx 60 cm
Acc. Voltage at Crest Vx 19.0 30 0 MV 0.25
Deccelerating Phase fx 160 deg 0.5 deg
Klystron Power P0 22 50 0 MW
Structure Power Ps 16 35 0 MW
Length of trans-line l 20 m
Structure Alignment Dy 0 mm 150 mm
10-m of WR-100 (rec) _at_ 1.00 dB, and 10-m of
WC-293 (circ) _at_ 0.04 dB
Pulse-to-pulse rms stability tolerance
Dec. 8, 2003 P. Emma
Write a Comment
User Comments (0)
About PowerShow.com