Title: TecnoCut PlateChanger Set Up /1
1TecnoCut PlateChanger Set Up /1
- HARDWARE (complete)
- both glued / not glued emulsion setup
- cabling of the interface PlateChanger - LNGS
level adapter board NI7344 - cabling and pneumatic connection of the
air/vacuum device for the glass window - cabling and pneumatic connection of the oil
dispenser - oil dispenser mechanical support (new design by
LNGS) -
- additional tools
- frame press to help vacuum on the glass window
(new design by LNGS) - compressed air nozzle to help emulsion detachment
from the glass window (electrovalve, cabling,
pneumatic connection and mechanical support) - compressed air to help emulsion detachment from
the cleaning tool surface (electrovalve, cabling,
pneumatic connection) - proximity switch to inhibit microscope movements
when platechanger arm is over the glass window
(switch, cabling, mechanical support)
Red whats new after last comunication
(2008.10.29)
2TecnoCut PlateChanger Set Up /2
- FIRMWARE (complete - version 4)
- platechanger state can be read outside for
synchronization with the software - emulsion counter is removed
- an additional input signal is provided to manage
the (un)load of the last emulsion plate - provide compressed air to help the emulsion
detachment from the cleaning tool surface - provide vacuum when the arm put the emulsion on
the cleaning tool surface
- SOFTWARE (minimal software available)
- Basic Digital IO interface complete (through new
module FlexStage5) - Scanning process integrated with oil distribution
(customized VertigoScan7) - Fiducial Mark Finding integrated with oil
distribution (new FlexMapX) - macros to manage the Load/Unload/OilDispense jobs
(new module TCPlateChanger) - Synchronization with the platechanger to improve
reliability at startup, after failures, (manage
problems like load command received when
unload is expected, restart after software or
platechanger crashes, )
3TecnoCut PlateChanger Set Up /3
- TEST AND MEASURE
- Full brick load/unload skipping oil (mark
finding, area scanning, ) ok (glued/not
glued) - Scanback and totalscan of some bricks (oil
distribution included) (after tuning of mark
finding and platechanger alignment tools) - not glued too lateral mark finding failures
(focus problems outside the vacuum channel due to
oil) - glued ok but frequent cleaning of separators,
suckers, surfaces,
4Conclusions
The hardware and firmware set up can be
considered closed for what concerns the requested
functionalities. Mark finding improvements
useful for not glued emulsions (in progress)
manage and/or trace the lateral mark clone
problem focusing before lateral mark
search Now, standard measures are necessary to
verify the reliability and stability of the
system.