Title: LSA Deployment for LHC
1LSA Deployment for LHC
- Mike Lamont on behalf of the LSA team
2Status
- LSA has been deployed
- LEIR
- SPS transfer lines TT40, CNGS, TI8, TI2
- Hardware Commissioning
- LHC power converter tests
- SM18
- Database is in good shape
- Technology well established
- Core software in place, tested and deployed
- Looking forward towards the LHC
3Requirements
- Core Functionality
- Settings management etc. etc. as detailed
- Equipment
- Instrumentation
- Measurements
- Operational exploitation
- Timing
- On-line Models
- MADX, FIDEL, Aperture
- Mode, data distribution
- Applied LSA applications
- Orbit, luminosity scans etc.
4LSA Core in action
5Settings Management
- Complex Parameter Space
- Momentum, Tune, Chromaticity, Orbit
- Magnet strengths, Multipole Errors, Decay,
Snapback.. - Power converter currents inc. nested triplets
- Knobs
- Kickers, Collimators, TDI
- Spectrometer compensation
- Crossing angle
- Separation bumps
?
- at least partially addressed
6Settings management
- Injection plateau
- Subset or all PCs
- Correctors for energy stability
- Multipole error compensation
- Prepare ramp
- Incorporation
- Calculation of snapback depth, adjustment of ramp
functions - Ramp
- Snapback, Stop
- Power Converters, RF, Collimators, Feedback
- Squeeze
- Q,Q, stop, adjust, continue, collimators,
feedback - Feed-forward Feedback
- From feedback systems
- From reference magnet systems
7Optics
- ramp and squeeze tests in all LHC IRs
- power converters in short circuit
- 7-8 for real
- Including running MAD, uploading optics etc
8Ramp
9Squeeze
10Squeeze
11FiDeL
- Import of coefficients on to staging tables
- Extraction to LSA tables
- Invocation of FiDel_at_LSA to produce
- Calibration curves
- Harmonic curves
- Settings generation
- Injection/decay
- Ramp/snapback
12Settings
- Pre-cycle configuration and generation
- Injection plateau
- Standard LHC ramp
- FiDeL deployed under LSA and tested
- Transfer functions (Calibration curves)
- Static harmonics
- Decay
- Snapback
- correction
13Parameter space
- Settings for dipole correctors in terms of
- Momentum
- Strength
- Current
- Cn
Point to the two available power converters as
necessary
14Decay
15Snapback b3
16Snapback - current
17Equipment
18INJECTION KICKERS ? X X X X X X
BEAM DUMP ? X X X X X X
POWER CONVERTERS X X X X
COLLIMATORS ? X X X X X
RF ?? X X X X X
LFB ? X X X X X
TFB ? X X X X
MAGNETS X X
MKQA X X X X
WARM MAGNETS X X X X
RADIATION MONITORS X X
SPECTROMETERS X X X
AnalogAcquisition
SoftwareInterlocks
CriticalSettings
PostMortem
XPOC
Timing
Application
Alarms
19Equipment
Generic equip state and equip monitor in place
Collimators Absorbers Parameter space, functions and actual settings, trim (s etc.) drive in place plus application (c/o Stefano)
Beam Dump GUI -
Beam dump XPOC Spec out. V0.1 prototype in place
Power converters Parameter space, functions, actual settings, trim, drive in place and tested.
Radio Frequency V0.1 slow control application. Requirement spec in.
Longitudinal Feedback ditto
Transverse Feedback ditto
Injection Kickers V0.1 application in place
Q aperture kicker, AC dipole -
20Instrumentation
21Instrumentation
BPMs X X X 1
BLMs X X X X 1 ?
BCT X 1
BTV X X X X 1 ?
Rest Gas X X X X 3 ?
Sync. Rad X X X X 1 ?
Wire Scanners X X X 2 ?
Luminosity X 1 ?
Tune etc. X X X X 1 ?
AGM X 2 ?
Schottky X 2 ?
Wall Current X 2 ?
BST 1
CriticalSettings
PostMortem
SWInterlocks
Priority
State
Settings
Logging
Concentration
GUI
22For all systems assume
- Fixed display
- standard unless otherwise stated
- Logging
- Standard
- SDDS
- Complex measurements
- Shot-by-shot data
- Post Mortem
- Standard API
- Analysis tools necessity driven
- Standard fitting routines
- Work in progress
23Measurements
- All measurements to be recorded together with
measurement parameters - Standard facilities for display, browsing and
analysis - Archiving, references etc.
- Access for post-mortem, post-run analysis, web
access etc. - Standard data format
- Interface to analysis tools
SDDS
24BLMLHC Beam Loss Monitors
- Concentration and re-publish
- Prototype in place
- Threshold Management/ Database configuration
- Work in progress (Trim Drive to crate..
management MCS expert app) - Triggered acquisition of snapshot buffer
- Triggered acquisition of XPOC buffer
- Dedicated fixed display/application
- Expert Application
- Logging
- Heavy filtering required, tests ongoing
25BPMLHC
- Capture, CO, PM, FIFO, XPOC
- Capture, CO, FIFO
- Concentration re-publish done
- Capture Multi-turn write to SDDS done
- Multi-turn application done
- Beta beating
- Work in progress
- Correction
- YASP alive and kicking actual trim
- Real-time
- Work in progress
- APIs to LSA (Twiss, corrections, etc.)
26BQBBQLHC
- Tune
- FFT
- Continuous FFT
- PLL
- (Feedback)
- Chromaticity
- Frequency modulation/PLL
- V3 requirements spec in circulation (LAFS)
- Daemon mode
27Instrumentation
Beam Loss Monitors acquisition concentration Ongoing, deployed, tests
Beam Loss Monitors display v2 Prototype
Beam Loss Monitors detailed app. To spec
Beam Loss Monitors MCS configuration tests Threshold tables in place, application to be done
Bunch Current Transformers acq display BCTDCLHC BCTFDLHC BCTFRLHC Fixed display in place
28First beam in LHC
29Instrumentation
BPM acquisition concentration publish V0.1 in place
BPM trajectory display Proto in place
BPM trajectory and orbit correction YASP
BPM multi-turn analysis V1 in place
BPM beta beating analysis Work in progress
BPMDLHC - dump line BPM -
BPMITLHC interlocked BPMs -
BTVI/BTVMLHC Screens (matching monitors) Extension of existing
30Instrumentation
Radmon acq conc - display proto done
BQHTLHC head-tail Chromaticity BI
BSRALHC Abort gap monitor
BSRTFLHC/BSRTSLHC Synchrotron radiation monitors LAFS first version in place
BGILHC Rest Gas Monitor LAFS
BWSLHC Wire Scanner LAFS first version in place
Wall Current Monitors (RF)
BQSLLHC - Schottky LAFS - specification
BRASCLHC/BRASGLHC - Luminosity monitors
31LHC BLM concentrator display
32Synchrotron radiation monitors
33Wire scanner
34BPM Concentration
35CMS Luminosity
36TIMING
ms Timing APIs for events, event tables, telegrams In place, preliminary tests performed
Client API In place
CBCM Injection request API Waiting
Timing application add, edit, load tables. Send events etc. Version 1 in place
Transfer synchronization pre-pulses - diagnostics To be tested
Synchronized actuation/measurement Spec in place
CTG high level diagnostics and monitoring
BOBR/BSTLHC Timing sections responsibility
37Timing
38Other stuff
39MAD FIDEL
40On-line models
On-line Model Requirements spec Implementation spec Prototype in place (trim knob generation)
FIDEL Prototype in place, magnet tests in progress
Aperture model Prototyping in progress
41OM
42Exploitation
Machine Sequencer Ongoing, many tests performed
Injection Sequencing Timing API in place to be tested
State machine implementation First prototype in place.
Shot Data Analysis On hold
43(No Transcript)
44Specific Applications
Orbit, threading, closure etc. etc. Done and dusted
Multi-turn analysis, beating etc. Work in progress
Luminosity optimization et al Specing
K-modulation SLAC
Collimator scans Work in progress
Measurement procedures aperture, dynamic aperture, matching, scans
45DEPLOYMENT AND TESTING
46(No Transcript)
47Individual system deployment
BPMs Crates as available concentration etc. Now
BLMs Crates as available concentration etc. Now
Stand alone BI systems As available Now
RF Slow control, settings, timing, monitoring as tests progress.
Collimators Track tests and system commissioning Now
Kickers Control, timing, analog acquisition Now
Beam dump XPOC, track system commissioning (essentially passive). Now
Core LSA as required
48HWC shadowing
LSA settings, trim Ramp, squeeze, experiments magnets, bumps, full parameter space
Power converters As implied in the above plus PM, monitoring etc. etc.
Magnets FIDEL as implied in the above
49Dry injection - December
Drive Injection sequence
Optics As usual
Settings Power converters, RF, Kickers, Collimators, Bumps, injection point steering
FIDEL 450 GeV decay, transfer functions
Timing BST, GMT, timing tables, events, telegrams, injection request, application, sequencer
Kickers Timing, control, analog acquisition
RF Pre-pulse
Standard facilities Mode, FD, logging, alarms
Collimators FSM, settings, monitoring
Screens Control, acquisition
BPMs, BLMs, WS, SRMs Event triggered acquisition,
50Dry sector test
- Drive full sector (cold magnets) through full
operational cycle - Large scale test of FIDEL, power converters,
timing - QPS, EE, cryogenics, PIC, PM
- Extend to cover
- Beam instrumentation
- Collimators (if available)
- Kickers
- TDI
- LHCb
Etc
51Conclusions
- For a large part, the implementation of LSA
functionality has been successfully performed. - Move to exploitation phase where we harness that
functionality to meet LHC requirements - The requisite software needs to be deployed and
tested over the coming months - Staged approached
- Individual systems
- HWC shadowing
- Dry runs
- Injection
- Sector
- Nsector