Title: SYMax to Quantum Quick Wiring Adapter QWA
1SY/Max to QuantumQuick Wiring Adapter (QWA)
Frank Prendergast Industrial Solution
Center Business Development Manager for
Services 978-975-9122 frank.prendergast_at_us.schneid
er-electric.com
2SY/Max to Quantum QWA
- What is the Quick Wiring Adapter
- Schneider Electric have designed a new Quantum
I/O terminal block that SY/Max terminal blocks
connect directly inside. - This allows SY/Max I/O to be quickly converted to
Quantum I/O without disturbing field wiring. - Cost and Productivity benefits of migrating to
Quantum - SY/Max is 187 more expensive than Quantum to
repair (on average) - SY/Max is 89 more expensive than Quantum to
exchange. (on average) - Quantum Mean Time Between Failure values are 4 to
20 times greater than SY/Max! - Quantum CPUs are 5 to 10x faster leading to
greater productivity
3SY/Max to Quantum QWA
- What is the value proposition?
- Utilize existing SY/Max field wiring and terminal
blocks - Less time and labor required to change
- Reduce chance of wiring errors
- Minimizes conversion time per drop
- MINIMIZE PLANT DOWNTIME (associated with the
upgrade) - Rewire 5 to 6 hours per drop QWA 1 hour
per drop - No wire is removed and circuit board in QWA is
validated to be correct. - Minimizes your overall RISK of change !
- Minimize your cost and equipment downtime with
less expensive more robust Quantum hardware.
4SY/Max to Quantum QWA
- How it is ordered.
- Please call 1-800-468-5342 extension 1 and ask
for Field Services. - and
- Email a list of all of the SY/Max modules that
you want to replace in an email to
customercentral_at_us.schneider-electric.com - We will send you a quotation for the new Quantum
modules, Quick Wiring Adapters, and SY/Max
adapter plates you need. - April 20th first customer order
- Lead time is 4 weeks
5SY/Max to Quantum QWA
- FAQs.
- Q. Is the new QWA any deeper or longer than my
SY/Max system? - A. Yes. The QWA is ½ inch longer and deeper.
- Q. How do I know what this QWA does
electronically? - A. The QWA connects wire to wire. Each QWA has a
unique part number on it that identifies which
SY/Max module and Quantum module it is designed
for. For example a HIM101DAI5400 states that it
is a SY/Max 8030HIM101 module connected to a
Quantum 140DAI5400 module. In addition a wiring
diagram is included with each QWA. - Q. Are there any limitations to using the QWA?
- A. The QWA was designed to handle the same worst
case electrical conditions as the SY/Max module
would encounter. - Q. Do I have to worry about electrical live
wires? - A. The QWA has a cover (same as standard Quantum
terminal block) so it offers the same safety as
long as the cover is closed.
6SY/Max to Quantum QWAInstallation Step 1
Observe all safety rules and turn off all power
sources going to the rack and I/O modules
! Remove all electrical power from the rack and
all non I/O modules
7SY/Max to Quantum QWAInstallation Step 2
Remove all I/O Terminal blocks from I/O modules
8SY/Max to Quantum QWAInstallation Step 3
Remove all I/O modules from the rack Remove the
SY/Max rack
9SY/Max to Quantum QWAInstallation Step 4
Install the SY/Max to Quantum Adapter plate
kit This allows you to install the
Quantum backplane without having to drill into
the enclosure sub-panel.
10SY/Max to Quantum QWAInstallation Step 5
Install the Quantum I/O modules in the same
location as previous SY/Max I/O module.
11SY/Max to Quantum QWAInstallation Step 6
Install the SY/Max to Quantum Quick Wiring
Adapter terminal block into the Quantum
I/O Module. Open the cover To the Quick
Wiring Adapter.
12SY/Max to Quantum QWAInstallation Step 7
Insert the SY/Max terminal block into the SY/Max
to Quantum QWA Close the cover. You are now
ready to startup your system knowing that the
wiring from your older SY/Max system is now
being used in your Quantum System !