Title: Mechanical Design
1Mechanical Design
2Mechanical Design Status
- Progress in all areas since CoDR.
- Most analysis is complete.
- Grating turret stiffness ?
- OIWFS gimbal mount stiffness (Budget)?
- Fine detailing of solid models to be completed.
- Duplicate Focal Plane Mask Wheel for Filter
Wheel. - Screws, washers, etc.
3NIFS Integration
4Handling the Cryostat
5Components on the OIWFS side of the Cold Work
Surface.
6View of OIWFS
7Helium Cryocooler Cold Straps
8OIWFS Assembly
9Shack-Hartmann Optics
10Two Facet Prism
11Focal Plane Unit
12Pick-Off Probe Guide Field
13Focal Plane Unit Components
14Focal Plane Mask Wheel
Motor full step moves mask 1/200 arcsec.
15F/Converter Cold Stop
16Pupil Baffling
17Components on the Spectrograph side of the Cold
Work Surface.
18Spectrograph Housing
19Spectrograph Components
20Housing Stiffness
- All towers bolt between CWS and Cover.
- Skirt bolts between CWS and Cover to form
structure with 250 nm deflection.
21Modules and Towers
22Filter-Fold Tower
23Fold Mirrors
24Tri-Fold Tower
25Tri-Fold Mirror
26Pupil Field Mirrors
27Pupil Array Machining
28Mirror Array Flexure
- Deflection under self load lt 300 nm (0.01 pixels
at detector). - Natural frequency 1000 Hz.
29Image Slicer Assembly
30Image Slicer Stack
31Slicer Fanning Axis
32Slicer Machining
33Bouwers Collimator Tower
34Bouwers Corrector Tower
35Grating Assembly
36Turret Shaft Flexure
Cantilevered 50 mm Dia. Deflection 0.000 3 mm
Cantilevered 25 mm Dia. Deflection 0.004 mm
Simply Supported 40 mm Deflection 0.000 06 mm
37Grating Drive System
- One motor step moves spectra one pixel on
detector. - On-axis drag brake locks turret.
38Grating Mount System
39Grating Drive Sectioned
Dynamic Overshoot 0.3 Pixels, Setting Error 0.03
Pixels
40Grating Drive Train
41Flip Mirror Assembly
42Spectrograph Baffling
43Baffle Evaluation
44Baffle Evaluation
45Spectrograph Camera
46Spectrograph Camera
47Detector Assembly
48Detector Circuit Card
49Detector Cabling
50Detector Cabling
51Detector Thermal
52Detector Thermal
53Detector Safe Handling
54Detector Service in Frame
55Spectrograph Alignment
56Cold Stop Alignment
57Image Slicer Alignment
58Grating Pupil Alignment
59The End
60(No Transcript)
61(No Transcript)
62Non-Common Path Phase Errors
63NIFS plus ALTAIR
- Artificial star from ALTAIR
- Differential flexure comparison
- Phase Maps, common path optics in NIFS
64- NIFS common path optics.
- Telescope focus -30mm to fill 2mm entrance
aperture. - Common path optics near focus see large changes
in footprint.
65- Phase maps from NIFS will be small.
- We can make phase maps by warming the cryostat
and moving the detector about -9mm. Our manual
focusser is designed for about -3mm.